Women sports wearer's comfort and health are greatly impacted by the breast movements and resultant sports bra compression to prevent excessive movement. However, as sports bras are only made in universal sizes, they do not offer the right kind of support that is required for a certain activity. To prevent this issue, textile-based strain sensors may be utilized to track compression throughout various activities to create activity-specific designed sports bras.

View Article and Find Full Text PDF

As monitoring and diagnostic tools for long COVID-19 cases, wearable systems and supervised learning-based medical image analysis have proven to be useful. Current research on these two technical roadmaps has various drawbacks, despite their respective benefits. Wearable systems allow only the real-time monitoring of physiological parameters (heart rate, temperature, blood oxygen saturation, or SpO).

View Article and Find Full Text PDF

This study presents the development and evaluation of an innovative intelligent garment system, incorporating 3D knitted silver biopotential electrodes, designed for long-term sports monitoring. By integrating advanced textile engineering with wearable monitoring technologies, we introduce a novel approach to real-time physiological signal acquisition, focusing on enhancing athletic performance analysis and fatigue detection. Utilizing low-resistance silver fibers, our electrodes demonstrate significantly reduced skin-to-electrode impedance, facilitating improved signal quality and reliability, especially during physical activities.

View Article and Find Full Text PDF

Background: Ventricular arrhythmia in hypertrophic cardiomyopathy (HCM) relates to adverse structural change and genetic status. Cardiovascular magnetic resonance (CMR)-guided electrocardiographic imaging (ECGI) noninvasively maps cardiac structural and electrophysiological (EP) properties.

Objectives: The purpose of this study was to establish whether in subclinical HCM (genotype [G]+ left ventricular hypertrophy [LVH]-), ECGI detects early EP abnormality, and in overt HCM, whether the EP substrate relates to genetic status (G+/G-LVH+) and structural phenotype.

View Article and Find Full Text PDF

Background: Electrocardiographic imaging (ECGI) generates electrophysiological (EP) biomarkers while cardiovascular magnetic resonance (CMR) imaging provides data about myocardial structure, function and tissue substrate. Combining this information in one examination is desirable but requires an affordable, reusable, and high-throughput solution. We therefore developed the CMR-ECGI vest and carried out this technical development study to assess its feasibility and repeatability in vivo.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on understanding how both overt and subclinical myocardial dysfunction affect health outcomes like mortality and frailty in older adults, using data from the long-term NSHD cohort.
  • Researchers intend to recruit 550 participants aged 75 and older to undergo advanced cardiovascular imaging techniques to improve understanding of heart health and disease in the elderly.
  • By combining rich, life-long health data with new imaging findings, the MyoFit46 project aims to clarify how different life stages and risk factors contribute to cardiovascular health in older age.
View Article and Find Full Text PDF

E-textiles reveal a new and hybrid sector of the industry that is created by the integration of electronic components or textile-based electronics in our daily life textile products. They are facing problems in terms of washability, reliability, and user acceptance. This manuscript explains the mechanical stresses acting during the washing process and their impact on e-textile systems.

View Article and Find Full Text PDF

Reliability and washability are major hurdles facing the e-textile industry nowadays. The main fear behind the product's rejection is the inability to ensure its projected life span. The durability of e-textiles is based on an approximate lifetime of both the electronics and textiles integrated into the product.

View Article and Find Full Text PDF

A development of washable PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) polyamide textile-based electrodes is an interesting alternative to the traditional Ag/AgCl disposable electrodes, usually used in clinical practice, helping to improve medical assessment and treatment before apparition or progress of patients' cardiovascular symptoms. This study was conducted in order to determine whether physical properties of PEDOT:PSS had a significant impact on the coated electrode's electrocardiogram (ECG) signal quality, particularly after 50 washing cycles in a domestic laundry machine. Tests performed, included the comparison of two PEDOT:PSS solutions, in term of viscosity with emphasis on wetting tests, including surface tension and contact angle measurements.

View Article and Find Full Text PDF

Long-term monitoring of the electrical activity of the heart helps to detect the presence of potential dysfunctions, enabling the diagnosis of a wide range of cardiac pathologies. However, standard electrodes used for electrocardiogram (ECG) acquisition are not fully integrated into garments, and generally need to be used with a gel to improve contact resistance. This article is focused on the development of washable screen-printed cotton, with and without Lycra, textile electrodes providing a medical quality ECG signal to be used for long-term electrocardiography measurements.

View Article and Find Full Text PDF

A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance.

View Article and Find Full Text PDF

In this paper, the washability of wearable textronic (textile-electronic) devices has been studied. Two different approaches aiming at designing, producing, and testing robust washable and reliable smart textile systems are presented. The common point of the two approaches is the use of flexible conductive PCB in order to interface the miniaturized rigid (traditional) electronic devices to conductive threads and tracks within the textile flexible fabric and to connect them to antenna, textile electrodes, sensors, actuators, etc.

View Article and Find Full Text PDF