Publications by authors named "Xue-chen Yang"

Background: Food systems instantiate the complex interdependencies across humans, physical environments, and other organisms. Applying One Health approaches for agri-food system transformation, which adopts integrated and unifying approaches to optimize the overall health of humans, animals, plants, and environments, is crucial to enhance the sustainability of food systems. This study develops a potential assessment tool, named the global One Health index-Food Security (GOHI-FS), aiming to evaluate food security performance across countries/territories from One Health perspective and identify relevant gaps that need to be improved for sustainable food systems.

View Article and Find Full Text PDF
Article Synopsis
  • The One Health approach is about keeping humans, animals, and the environment healthy together, and it's become more important because of issues like climate change and disease outbreaks.
  • In China, while they're doing well in food security and managing drug resistance, they struggle more with climate change compared to other countries.
  • Experts suggest that China needs a better plan to turn policies into real actions, and they should work together with different people and cultures to make this happen.
View Article and Find Full Text PDF

Adhesion G protein-coupled receptors are elusive in terms of their structural information and ligands. Here, we solved the cryogenic-electron microscopy (cryo-EM) structure of apo-ADGRG2, an essential membrane receptor for maintaining male fertility, in complex with a G trimer. Whereas the formations of two kinks were determinants of the active state, identification of a potential ligand-binding pocket in ADGRG2 facilitated the screening and identification of dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate and deoxycorticosterone as potential ligands of ADGRG2.

View Article and Find Full Text PDF

Optical micro-ring resonator prepared on Silicon-On-Insulator (SOI) has high sensitivity, small size and low mode volume. Its high sensitivity has been widely applied to the optical information transmission and inertial navigation devices field, while it is rarely applied in the testing of Mechanics. This paper presents a cantilever stress/strain gauge with an optical microring resonator.

View Article and Find Full Text PDF

Because traditional method for tunable grating fabrication has harsh process condition, complex fabrication process, high costs and long cycle. Proposed a low-cost, simple process, can be prepared in large quantities gradient grating process method, based on self-assembly process using the rigid film/flexible substrate and oxygen plasma method prepared a micron scale gradient grating. Use of plasma free time controllability and excellent elastic of PDMS obtained the desired grating.

View Article and Find Full Text PDF

A refractive index sensor composed of two straight metal-insulator-metal waveguides and a ring resonator is presented. One end of each straight waveguide is sealed and the other end acts as port. The transmission spectrum and magnetic field distribution of this sensor structure are simulated using finite-difference time-domain method (FDTD).

View Article and Find Full Text PDF

This research used batch soil column experiment to study the effects of irrigating with reclaimed water and tap water on the soil chemical properties and culturable microorganisms. The results indicated that reclaimed water could markedly increase the soil organic material (OM) and total nitrogen (TN) content, but it had no obvious effect on total phosphorus (TP), available phosphorus (AP) and pH value. Reclaimed water irrigation could significantly enhance the amounts of surface soil bacteria and actinomycetes at a depth of 0-20 cm, but it had little effect on the biomass of 20-40 cm and 40-60 cm soil layers.

View Article and Find Full Text PDF

In this paper, the potential sensitivity in Kelvin probe force microscopy (KPFM) was investigated in frequency modulation (FM) and heterodyne amplitude modulation (AM) modes. We showed theoretically that the minimum detectable contact potential difference (CPD) in FM-KPFM is higher than in heterodyne AM-KPFM. We experimentally confirmed that the signal-to-noise ratio in FM-KPFM is lower than that in heterodyne AM-KPFM, which is due to the higher minimum detectable CPD dependence in FM-KPFM.

View Article and Find Full Text PDF

We propose and realize a novel packaged microsphere-taper coupling structure (PMTCS) with a high quality factor (Q) up to 5×10(6) by using the low refractive index (RI) ultraviolet (UV) glue as the coating material. The optical loss of the PMTCS is analyzed experimentally and theoretically, which indicate that the Q is limited by the glue absorption and the radiation loss. Moreover, to verify the practicability of the PMTCS, thermal sensing experiments are carried out, showing the excellent convenience and anti-jamming ability of the PMTCS with a high temperature resolution of 1.

View Article and Find Full Text PDF

The MEMS vector hydrophone is a novel acoustic sensor with a "four-beam-cilia" structure. Based on the MEMS vector hydrophone with this structure, the paper studies the method of estimated direction of arrival (DOA). According to various research papers, many algorithms can be applied to vector hydrophones.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionvqbu1ha84dnrblfg17dvaaif47t0q6r0): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once