In the water with petroleum pollution, the petroleum will be adsorbed on the surface of suspended particulate matter and form a double-layer structure, which impacts on the spectrum characteristics to the scattering coefficient. It is a key to improve the accuracy of the scattering theory model that the contribution of petroleum substances and suspended particulate matter on the scattering spectrum coefficient is be separated. A backward scattering coefficient spectrum measurement system was being built from linkage observation of three kinds of instruments, including DAWN HELEOS Ⅱ18 angle scattering measuring instrument (Wyatt company, American), LISST-100-xB size instrument(SEQUOIA SCIENTIFIC, INC, American), HydroScat-6 Sprctral Backscattering Sensor (HS6) ( Hobilabs company, American).
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
September 2014
In four ratio experiments, natural waters, sampled from the mountain reservoir and the sea water around Dalian city, were mixed with the sewage from petroleum refinery and petroleum exploitation plants. The fluorescence spectra of water samples containing only chromophoric dissolved organic matters(CDOM), samples containing only petroleum, and samples containing a mixture of petroleum and CDOM were analyzed, respectively. The purpose of this analysis is to provide a basis for determining the contribution of petroleum substances and CDOM to the total absorption coefficient of the petroleum-contaminated water by using fluorescence technique.
View Article and Find Full Text PDF