Background: Magnetic resonance-guided adaptive radiotherapy (MRgART) at MR-Linac allows for plan optimisation on the MR-based synthetic CT (sCT) images, adjusting the target and organs at risk according to the patient's daily anatomy. Conversely, conventional linac image-guided radiotherapy (IGRT) involves rigid realignment of regions of interest to the daily anatomy, followed by the delivery of the reference computed tomography (CT) plan. This study aims to evaluate the effectiveness of MRgART versus IGRT for rectal cancer patients undergoing short-course radiotherapy, while also assessing the dose accumulation process to support the findings and determine its usefulness in enhancing treatment accuracy.

View Article and Find Full Text PDF

Background: Breast cancer is the most widespread cancer in women and young women worldwide. Moving towards customised radiotherapy, balancing the use of the available technology with the best treatment modality may not be an easy task in the daily routine. This study aims to evaluate the effectiveness of introducing IQ-feasibility into clinical practice to support the decision of free-breathing (FB) versus breath-hold (BH) left-sided breast irradiations, in order to optimise the technology available and the effectiveness of the treatment.

View Article and Find Full Text PDF

Background: Magnetic resonance-guided adaptive radiotherapy (MRgART) treatment sessions at MR-Linac are time-consuming and changes in organs at risk volumes can impact the treatment dosimetry. This study aims to evaluate the feasibility to control bladder filling during the rectum MRgART online session and its effectiveness on plan dosimetry.

Methods: A total of 109 online adaptive sessions of 24 rectum cancer patients treated at Unity 1.

View Article and Find Full Text PDF

Adaptive radiotherapy performed on the daily magnetic resonance imaging (MRI) is an option to improve the treatment quality. In the adapt-to-shape workflow of 1.5-T MR-Linac, the contours of structures are adjusted on the basis of patient daily MRI, and the adapted plan is recalculated on the MRI-based synthetic computed tomography (syCT) generated by bulk density assignment.

View Article and Find Full Text PDF

Background And Purpose: To analyze the distribution pattern of lymph nodes (LNs) metastasis of level Ib in nasopharyngeal cancer (NPC) and propose shrinkage of clinical target volume (CTV) boundaries to avoid unnecessary radiation for some space with very low-risk of involvement.

Materials And Methods: Pretreatment images of pathologically proven NPC patients were reviewed and those with positive level Ib LN metastasis was enrolled. The geometric center of each level Ib LN in the neck was marked on a template CT.

View Article and Find Full Text PDF

Background: to explore the feasibility and effectiveness of para-split laminotomy in the treatment of lumbar intraspinal tumors.

Methods: We retrospectively review the clinical data of 15 patients suffering lumbar intraspinal tumors, who underwent tumor resection using the para-split laminotomy, from October 2016 to May 2018. Observation indicators were as follows: (1) surgical and postoperative recovery situations; (2) the neurological function of the spinal cord and the follow-up situations.

View Article and Find Full Text PDF

In breast radiotherapy, the proximity of the target to sensitive structures together with the uncertainty introduced by respiratory movement, make this treatment one of the most studied to increase its effectiveness. Dosimetric and physical variables play an important role and the study of their correlation and impact on treatment is fundamental. This retrospective study aims to highlight the dosimetric differences of 2 different clinical data sets of patients receiving left-sided breast irradiation in free breathing (FB) or breath hold (BH).

View Article and Find Full Text PDF

Incidental radiation exposure to the heart during lung cancer radiotherapy is associated with radiation-induced heart disease and increased rates of mortality. By considering the respiratory-induced motion of the heart it is possible to create a radiotherapy plan that results in a lower overall cardiac dose. This approach is challenging using current clinical practices: manual contouring of the heart is time consuming, and subject to inter- and intra-observer variability.

View Article and Find Full Text PDF

Background: Volumetric modulated arc therapy (VMAT) adopted in post-mastectomy radiation therapy (PMRT) has the capacity to achieve highly conformal dose distributions. The research aims to evaluate the impact of positioning errors in the dosimetry of VMAT left-sided PMRT.

Methods: A total of 18 perturbations where introduced in 11 VMAT treatment plans that shifted the isocenter from its reference position of 3, 5, 10 mm in six directions.

View Article and Find Full Text PDF

Postmastectomy radiation therapy is technically difficult and can be considered one of the most complex techniques concerning patient setup reproducibility. Slight patient setup variations - particularly when high-conformal treatment techniques are used - can adversely affect the accuracy of the delivered dose and the patient outcome. This research aims to investigate the inter-fraction setup variations occurring in two different scenarios of clinical practice: at the reference and at the current patient setups, when an image-guided system is used or not used, respectively.

View Article and Find Full Text PDF

Acute skin toxicity observed in radiotherapy treatment of head and neck cancer is a big concern. The purpose of this work is to evaluate the feasibility of a skin dose reduction in the treatment of nasopharyngeal carcinoma without compromising the overall plan quality. This research focused on comparison of the skin dose reduction that can be obtained for the main high conformal radiotherapy delivery techniques.

View Article and Find Full Text PDF

High conformal techniques such as intensity-modulated radiation therapy and volumetric-modulated arc therapy are widely used in overloaded radiotherapy departments. In vivo dosimetric screening is essential in this environment to avoid important dosimetric errors. This work examines the feasibility of introducing in vivo dosimetry (IVD) checks in a radiotherapy routine.

View Article and Find Full Text PDF

The goal of this study was to evaluate the use of multi-criteria optimization (MCO) in the planning and optimization of intensity-modulated radiotherapy (IMRT). Twenty (20) IMRT patients (ten (10) with prostate cancer and ten (10) with lung cancer) were randomly selected. The treatment plans for these patients were designed using direct machine parameter optimization (DMPO).

View Article and Find Full Text PDF

On-line megavoltage computed tomography (MVCT) images are used to verify patient daily set-up in Hi-ART helical TomoTherapy unit. To evaluate the patient dose from MVCT scanning in image guidance, weighted computed tomography (CT) dose index (CTDI) was measured with PTW TM30009 CT pencil chamber in head and body phantoms for slice thicknesses of 2, 4 and 6 mm with different scan lengths. Dose length products (DLPs) were subsequently calculated.

View Article and Find Full Text PDF

To evaluate the Elekta kilovoltage CBCT doses and the associated technical protocols with patient dosimetry estimation. Image guidance technique with cone-beam CT (CBCT) in radiation oncology on a daily basis can deliver a significant dose to the patient. To evaluate the patient dose from LINAC-integrated kV cone beam CT imaging in image-guided radiotherapy.

View Article and Find Full Text PDF

Background: The accuracy of dose calculation is crucial to the quality of treatment planning and, consequently, to the dose delivered to patients undergoing radiation therapy. Current general calculation algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone Convolution (CCC) have shortcomings in regard to severe inhomogeneities, particularly in those regions where charged particle equilibrium does not hold. The aim of this study was to evaluate the accuracy of the PBC and CCC algorithms in lung cancer radiotherapy using Monte Carlo (MC) technology.

View Article and Find Full Text PDF

Objective: To evaluate the radiation output and stability of linac-integrated kV cone beam CT unit.

Methods: Air kermas in radiographic mode were measured with 0.6 cc ion chamber and Unidos electrometer for Synergy-integrated XVI kV cone beam CT unit.

View Article and Find Full Text PDF