Publications by authors named "Xiaoqiang Pei"

A miniature reflectron time-of-flight mass spectrometer (TOF MS) with orthogonal extraction coupled with electron impact (EI) ionization source can be used to perform in situ gas composition analysis in a planetary environment. However, performances such as the mass resolution, sensitivity, limit of detection, mass range, and mass accuracy are often decreased because of miniaturization. Herein, a compact instrument for space applications has been developed, and its performance has been evaluated.

View Article and Find Full Text PDF

Silver loaded nanofibrous membrane with high catalytic performance for 4-nitrophenol under continuous gravity-driven filtration was developed in this study. A polydopamine (PDA) microsphere and nanofiber coordinated composite structure was fabricated through an in situ PDA synthesis to achieve a high catalyst loading and controllable residence time of 4-nitrophenol. The incorporated PDA microspheres played an important role for the enhancement of catalytic performance due to the increased surface area (23% increase compared with PAN and PAN-PDAs-Ag) and reduced membrane porosity.

View Article and Find Full Text PDF

A miniaturized linear ion trap mass spectrometer with continuous atmospheric pressure interface has been built in our lab. Significant extension in mass range and reduction in power consumption have been realized by the supplemental alternating current frequency scan mode. However, relatively poor sensitivity has been witnessed, which is directly dominated by the detection efficiency of the ion detector.

View Article and Find Full Text PDF

A miniaturized ion trap mass spectrometer with continuous atmospheric pressure interface was built, which could be used in conjunction with internal ionization (in-vacuum plasma ionization) and external ionization (electrospray ionization). To improve its mass range, a supplemental AC signal frequency scan mode was performed for this miniature mass spectrometer, in which the fundamental RF signal was remained constant with an amplitude as low as several hundreds volts. Experiments showed that the upper limit of the mass range can be extended to 2500 Da for the miniature mass spectrometer developed in this work, and the power consumption can be reduced by 2/5, while maintaining good balance with performance parameters such as stability, sensitivity, and resolution.

View Article and Find Full Text PDF

In this paper, the effects of constant uniform magnetic fields on a miniature linear ion trap mass spectrometer with hyperbolic electrodes are simulated using SIMION 8.0 3D software. Magnetic fields in different directions have different effects on the trajectories of the trapped ions and the shape of the ion cloud.

View Article and Find Full Text PDF

With the rapid development of space technology in China, it is urgent to use mass spectrometer to detect the space environment. In this work, a space miniature magnetic sector mass spectrometer is evaluated, which consists of three subsystems: (1) physical unit, (2) electric control unit, (3) and high voltage power. It has 90° magnetic sector-field analyzer with double trajectory, in which a trajectory measurement range is from 1 to 12 amu, the other range is from 6 to 90 amu.

View Article and Find Full Text PDF

Pollution Status and characteristics of PBDEs in offices were investigated in Hangzhou. As a result, the total concentration of PBDEs was 40.66-141.

View Article and Find Full Text PDF

Air pollution surveys of formaldehyde (HCHO) were conducted in 2324 rooms decorated within one year in 2007-2009 in Hangzhou, China. The mean HCHO concentration (CHCHO) was 0.107 +/- 0.

View Article and Find Full Text PDF