Background: Previous studies on the impact of mitochondrial DNA (mtDNA) copy number on female infertility were limited and inconsistent.
Methods: The causal relationship between mtDNA copy number and female infertility was evaluated using a bidirectional 2-sample Mendelian randomization (MR) method. Inverse variance weighted (IVW) method was applied for principal analysis, and MR-Egger, weighted median, simple mode, weighted mode method for secondary analyses.
Reprod Biol Endocrinol
September 2019
Background: Although in vitro culture system has been optimized in the past few decades, the problem of few or no high quality embryos has been still not completely solved. Accordingly, fully understanding the regulatory mechanism of pre-implantation embryonic development would be beneficial to further optimize the in vitro embryo culture system. Recent studies have found the expression of c-kit in mouse embryo and its promotion effects on mouse embryonic development.
View Article and Find Full Text PDFThe determination of pesticide residues is an indispensable task in controlling food safety and environment protection. Carbendazim is one of the extensive uses of pesticides in the agricultural industry. In this study, a simple method utilizing syringe filter has been applied as electrospray ionization emitter for mass spectrometric identification and quantification of carbendazim in complex matrices including soil, natural water, and fruit juice samples, which contain many insoluble materials.
View Article and Find Full Text PDFPolycyclic aromatic hydrocarbons (PAHs) are environmental contaminants with carcinogenic effect raising worldwide concerns. Hydroxylated PAHs (OH-PAHs) could be formed in the body as metabolites of PAHs in human urine samples and thus considered as biomarkers of PAH exposure. In this study, five OH-PAHs including 3-phenanthrol, 1-naphthol, 2-hydroxy fluorene, 1-hydroxprene and 6-hydroxy chrysene in human urine samples were selectively enriched by C18 solid-phase microextraction (SPME), then SPME fiber was connected high voltage and then was inserted into a glass-capillary to elute and ionize the analytes for mass spectrometric (MS) detection.
View Article and Find Full Text PDFZhongguo Shi Yan Xue Ye Xue Za Zhi
August 2011
The purpose of this study was to determine whether the fully automated ORTHO AutoVue Innova system, which based on the microcolumn glass sphere technology, is accurate enough to meet immunohematology testing needs at blood banks. 16 IgM anti-C, anti-c, anti-D, anti-E and anti-e dilution series were tested respectively, with corresponding antigen positive red blood cell solutions, by ORTHO AutoVue Innova system and saline medium test. 16 IgG anti-D dilution series were tested respectively with RhD positive red blood cell solutions by ORTHO AutoVue Innova system, polybrene test and antiglobulin test.
View Article and Find Full Text PDF