Conventional mass analysis has been investigated experimentally with six quadrupole mass filters with added hexapole fields; three with added hexapole fields of 4%, 8% and 12% with equal diameter rods, and three with added hexapole fields of 4%, 8% and 12% with unequal diameter rods to remove an added octopole field. Compared with conventional quadrupoles, these rod sets have very large field distortions. With the positive resolving dc applied to the y rods (Mathieu parameter a(x) < 0) only low resolution (10-100) and low transmission are seen.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
March 2010
Mass analysis with islands of stability has been investigated with three linear quadrupole mass filters: two with 4% added hexapole fields constructed with equal diameter (quadrupole 4A) and unequal diameter (quadrupole 4B) rods, and a conventional round-rod quadrupole that has apparently been slightly damaged. Islands are formed by applying auxiliary quadrupole excitation. With the Mathieu parameter, a < 0, mass analysis with both quadrupoles with hexapole fields operated normally, i.
View Article and Find Full Text PDFWe have constructed, and tested as mass filters, linear quadrupoles with added hexapole fields of 4%, 8%, and 12%, with and without added octopole fields. A hexapole field can be added to the field of a linear quadrupole by rotating the two y rods toward an x rod. This also adds an octopole field which can be removed by making the x rods greater in diameter than the y rods.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
April 2008
Modeling and experimental studies of quadrupole excitation of ions in linear quadrupole traps with added octopole fields are described. An approximate solution to the equations of motion of ions trapped in a quadrupole with added octopole and dodecapole fields, with quadrupole excitation and damping is given. The solutions give the steady-state or stationary amplitudes of oscillation with different excitation frequencies.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
May 2007
Mass analysis with linear quadrupole mass filters is possible by forming "islands" in the stability diagram with auxiliary quadrupole excitation. In this work, computer simulations are used to calculate stability boundaries, island positions, and peak shapes and ion transmission for mass analysis with linear quadrupole mass filters that have added octopole fields of about 2 to 4%. Rod sets with exact geometries that have quadrupole and octopole fields only in the potential, and round rod sets, with multipoles up to N = 10 (the twenty pole term) included in the calculations, show the same stability boundaries, island positions, and peak shapes.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
June 2005
Modeling of ion motion and experimental investigations of ion excitation in a linear quadrupole trap with a 4% added octopole field are described. The results are compared with those obtained with a conventional round rod set. Motion in the effective potential of the rod set can explain many of the observed phenomena.
View Article and Find Full Text PDF