Background: Hypercapnia worsens lung vascular dysfunction during acute respiratory distress syndrome (ARDS). We tested whether an extracorporeal carbon dioxide removal (ECCOR) device based on a renal replacement therapy platform (Prismalung®) may reduce PaCO and alleviate lung vascular dysfunction in ARDS patients with refractory hypercapnia.
Methods: We planned to prospectively include 20 patients with moderate-to-severe ARDS, pulmonary vascular dysfunction on echocardiography, and PaCO ≥ 48 mmHg despite instrumental dead space reduction and the increase in respiratory rate.
Background: Severe hypothyroidism (SH) is a rare but life-threatening endocrine emergency. Only a few data are available on its management and outcomes of the most severe forms requiring ICU admission. We aimed to describe the clinical manifestations, management, and in-ICU and 6-month survival rates of these patients.
View Article and Find Full Text PDFObjective: Incidence of right ventricular (RV) failure in septic shock patients is not well known, and tricuspid annular plane systolic excursion (TAPSE) could be of limited value. We report the incidence of RV failure in patients with septic shock, its potential impact on the response to fluids, as well as TAPSE values.
Design: Ancillary study of the HEMOPRED prospective multicenter study includes patients under mechanical ventilation with circulatory failure.
Objectives: Thyroid storm represents a rare but life-threatening endocrine emergency. Only rare data are available on its management and the outcome of the most severe forms requiring ICU admission. We aimed to describe the clinical manifestations, management and in-ICU and 6-month survival rates of patients with those most severe thyroid storm forms requiring ICU admission.
View Article and Find Full Text PDFPurpose: Bereavement research has helped to improve end-of-life practices in the ICU. However, few studies have explored bereaved relatives experience of research participation in this context. We aimed to explore the experience of bereaved relatives' participation in the ARREVE study which included three telephone follow-up calls to complete several quantitative tools.
View Article and Find Full Text PDFPurpose: Mechanisms of circulatory failure are complex and frequently intricate in septic shock. Better characterization could help to optimize hemodynamic support.
Methods: Two published prospective databases from 12 different ICUs including echocardiographic monitoring performed by a transesophageal route at the initial phase of septic shock were merged for post hoc analysis.
Evaluation of intrathoracic pressure is the cornerstone of the understanding of heart-lung interactions, but is not easily feasible at the bedside. Esophageal pressure (P) has been shown to be a good surrogate for intrathoracic pressure and can be more easily measured using a small esophageal catheter, but is not routinely employed. It can provide crucial information for the study of heart-lung interactions in both controlled and spontaneous ventilation.
View Article and Find Full Text PDFPurpose: We sought to determine the diagnostic ability of the end-expiratory inferior vena cava diameter (IVC) to predict fluid responsiveness (FR) and the potential confounding effect of intra-abdominal pressure (IAP).
Methods: In this multicenter study, 540 consecutive ventilated patients with shock of various origins underwent an echocardiographic assessment by experts. The IVC, velocity time integral (VTI) of the left ventricular outflow tract (LVOT) and intra-abdominal pressure (IAP) were measured.
Correction to: Intensive Care Med (2017) DOI 10.1007/s00134-017-4891-0.
View Article and Find Full Text PDFPurpose: The relative merits of immediate extubation versus terminal weaning for mechanical ventilation withdrawal are controversial, particularly regarding the experience of patients and relatives.
Methods: This prospective observational multicentre study (ARREVE) was done in 43 French ICUs to compare terminal weaning and immediate extubation, as chosen by the ICU team. Terminal weaning was a gradual decrease in the amount of ventilatory assistance and immediate extubation was extubation without any previous decrease in ventilatory assistance.
Acute respiratory distress syndrome (ARDS) is burdened with significant mortality, mainly in connection with circulatory failure. The right ventricle (RV) is the weak link of hemodynamic stability among ARDS patients and its failure, also named "severe" acute cor pulmonale (ACP), is responsible for excess mortality. Driving pressure ≥18 cmHO, PaCO ≥48 mmHg and PaO/FiO <150 mmHg are three preventable factors recently identified as independently associated with ACP, on which ventilator strategy designed to protect the RV has to focus.
View Article and Find Full Text PDFBackground: The transmission of extended-spectrum beta-lactamase-producing enterobacteriaceae (ESBL) is prevented by additional contact precautions, mainly relying on isolation in a single room and hand hygiene. Contact isolation cannot be achieved in our 12-bed ICU, which has only double rooms. We report the epidemiology of ESBL imported, acquired and transmitted in an ICU with no single rooms.
View Article and Find Full Text PDFMean systemic filling pressure (P) defines the pressure measured in the venous-arterial system when the cardiac output is nil. Its estimation has been proposed in patients with beating hearts by building the venous return curve, using different pairs of right atrial pressure/cardiac output during mechanical ventilation. We raised the hypothesis according to which the P is altered by tidal ventilation and positive end-expiratory pressure (PEEP), which would challenge this extrapolation method based on cardiopulmonary interactions.
View Article and Find Full Text PDFRationale: Assessment of fluid responsiveness relies on dynamic echocardiographic parameters that have not yet been compared in large cohorts.
Objectives: To determine the diagnostic accuracy of dynamic parameters used to predict fluid responsiveness in ventilated patients with a circulatory failure of any cause.
Methods: In this multicenter prospective study, respiratory variations of superior vena cava diameter (∆SVC) measured using transesophageal echocardiography, of inferior vena cava diameter (∆IVC) measured using transthoracic echocardiography, of the maximal Doppler velocity in left ventricular outflow tract (∆VmaxAo) measured using either approach, and pulse pressure variations (∆PP) were recorded with the patient in the semirecumbent position.
Acute respiratory distress syndrome (ARDS) remains associated with a poor outcome despite recent major therapeutic advances. Forecasting the outcome of patients suffering from such a syndrome is of a crucial interest and many scores have been proposed, all suffering from limits responsible for important discrepancies. Authors try to elaborate simple, routine and reliable scores but most of them do not consider hemodynamics yet acknowledged as a major determinant of outcome.
View Article and Find Full Text PDFAcute respiratory failure (ARF) is a leading indication for performing critical care ultrasonography (CCUS) which, in these patients, combines critical care echocardiography (CCE) and chest ultrasonography. CCE is ideally suited to guide the diagnostic work-up in patients presenting with ARF since it allows the assessment of left ventricular filling pressure and pulmonary artery pressure, and the identification of a potential underlying cardiopathy. In addition, CCE precisely depicts the consequences of pulmonary vascular lesions on right ventricular function and helps in adjusting the ventilator settings in patients sustaining moderate-to-severe acute respiratory distress syndrome.
View Article and Find Full Text PDFPulmonary vascular dysfunction is associated with ARDS and leads to increased right-ventricular afterload and eventually right-ventricular failure, also called acute cor pulmonale. Interest in acute cor pulmonale and its negative impact on outcome in patients with ARDS has grown in recent years. Right-ventricular function in these patients should be closely monitored, and this is helped by the widespread use of echocardiography in intensive care units.
View Article and Find Full Text PDFPurpose: Terminal extubation (TE) and terminal weaning (TW) are the methods available for withdrawing mechanical ventilation. Perceptions of TE and TW by intensive care unit (ICU) staff may influence bedside practices and the feasibility of studies comparing these methods.
Methods: From January to June 2013, 5 nurses and 5 physicians in each of 46 (out of 70, 65.
Background: Our aim was to evaluate the impact of a computerized echocardiographic simulator on the learning curve for transesophageal echocardiography (TEE) hemodynamic assessment of ventilated patients in the ICU.
Methods: We performed a prospective study in two university hospital medical ICUs. Using our previously validated skill assessment scoring system (/40 points), we compared learning curves obtained with (interventional group, n = 25 trainees) and without (control group, n = 31 trainees) use of a simulator in the training.
Curr Opin Crit Care
June 2016
Purpose Of Review: The right ventricle (RV) plays a pivotal role during respiratory failure because of its high sensitivity to small loading changes during inspiration. Both RVs, preload and afterload, are altered during inspiration, either in spontaneous breathing or during mechanical ventilation. Some clinical situations especially affect RV load during inspiration, for example acute asthma and acute respiratory distress syndrome.
View Article and Find Full Text PDF