Illicit drugs are a global burden, not only for society, but also for the various control authorities for which its rapid on-site detection remains a challenge. In this context, the potential of a voltammetric electronic tongue (ET) for the analysis of different drugs is evaluated herein. Concretely, the discrimination and identification of cocaine, heroin, 3,4-Methylenedioxymethamphetamine (MDMA), methamphetamine and ketamine in self-prepared and real samples were attempted.
View Article and Find Full Text PDFProtein haze in white wine can be a serious quality defect because consumers perceive hazy wines as "spoiled". Unfortunately, a specific method for the detection, or selective treatment, of such proteins in affected wines does not exist. Herein we investigate on the development of an easy-to-use sensor device that allows detection of haze-forming proteins (HFPs).
View Article and Find Full Text PDFElectronic tongues (ETs) are multisensor systems based on the coupling of different sensors with high stability and cross-sensitivity towards different species, along with an appropriate chemometric tool that allow the classification of samples and/or the quantification of selected analytes. Despite the great advantages that the data processing stage may offer (e.g.
View Article and Find Full Text PDFFluoroquinolones (FQs) are one of the most important types of antibiotics in the clinical, poultry, and aquaculture industries, and their monitoring is required as the abuse has led to severe issues, such as antibiotic residues and antimicrobial resistance. In this study, we report a voltammetric electronic tongue (ET) for the simultaneous determination of ciprofloxacin, levofloxacin, and moxifloxacin in both pharmaceutical and biological samples. The ET comprises four sensors modified with three different customized molecularly imprinted polymers (MIPs) and a nonimprinted polymer integrated with Au nanoparticle-decorated multiwall carbon nanotubes (Au-fMWCNTs).
View Article and Find Full Text PDFAssessment of water and soil quality is critical for the health, economy, and sustainability of any community. The release of a range of life-threatening pollutants from agriculture, industries, and the residential communities themselves into the different water resources and soil requires of analytical methods intended for their detection. Given the challenge that represents coping with the monitoring of such a diverse and large number of compounds (with over 100,000 chemicals registered, yet in continuous increase), holistic solutions such as electronic tongues (ETs) are emerging as a promising tool for a sustainable, simple, and green monitoring of soil and water resources.
View Article and Find Full Text PDFThe combination of chemometrics and electrochemical sensors modified with molecularly imprinted polymers (MIPs) towards the development of MIP-based electronic tongues (ETs) was explored herein. To demonstrate the potential of such an approach, the simultaneous determination of paracetamol, ascorbic acid and uric acid mixtures in pharmaceutical samples was evaluated. To this aim, MIP-based sensors for the different compounds were prepared by in situ electropolymerization of pyrrole in the presence of p-toluenesulfonate anion (pTS), which acted as functional doping ion of the polypyrrole (PPy) MIP backbone.
View Article and Find Full Text PDFMolecularly imprinted polymers (MIPs) are artificially synthesized materials to mimic the molecular recognition process of biological macromolecules such as substrate-enzyme or antigen-antibody. The combination of these biomimetic materials with electrochemical techniques has allowed the development of advanced sensing devices, which significantly improve the performance of bare or catalyst-modified sensors, being able to unleash new applications. However, despite the high selectivity that MIPs exhibit, those can still show some cross-response towards other compounds, especially with chemically analogous (bio)molecules.
View Article and Find Full Text PDFThe application of a voltammetric electronic tongue (ET) towards the classification and authentication of vinegar is reported. Vinegar samples of different varieties were analysed with a three-sensor array, without performing any sample pre-treatment, but only an electrochemical cleaning stage between sample measurements to avoid fouling onto the electrode surfaces. Next, the use of discrete cosine transform (DCT) for the compression and reduction of signal complexity in voltammetric measurements was explored, and the number of coefficients was optimized through its inverse transform.
View Article and Find Full Text PDFHerein we investigate the usage of principal component analysis (PCA) and canonical variate analysis (CVA), in combination with the F factor clustering metric, for the a priori tailored selection of the optimal sensor array for a given electronic tongue (ET) application. The former allows us to visually compare the performance of the different sensors, while the latter allows us to numerically assess the impact that the inclusion/removal of the different sensors has on the discrimination ability of the ET. The proposed methodology is based on the measurement of a pure stock solution of each of the compounds under study, and the posterior analysis by PCA/CVA with stepwise iterative removal of the sensors that demote the clustering when retained as part of the array.
View Article and Find Full Text PDFThis work reports the applicability of a voltammetric sensor array able to quantify the content of 2,4-dinitrophenol, 4-nitrophenol, and picric acid in artificial samples using the electronic tongue (ET) principles. The ET is based on cyclic voltammetry signals, obtained from an array of metal disk electrodes and a graphite epoxy composite electrode, compressed using discrete wavelet transform with chemometric tools such as artificial neural networks (ANNs). ANNs were employed to build the quantitative prediction model.
View Article and Find Full Text PDFThis work reports the application of an electronic tongue as a tool towards the analysis of wine in tasks such as its discrimination based on the maturing in barrels or the prediction of the global scores assigned by a sensory panel. To this aim, red wine samples were first analysed with the voltammetric sensor array, without performing any sample pretreatment. Afterwards, obtained responses were preprocessed employing fast Fourier transform (FFT) for the compression and reduction of signal complexity, and obtained coefficients were then used as inputs to build the qualitative and quantitative models employing either linear discriminant analysis (LDA) or partial least squares regression (PLS), respectively.
View Article and Find Full Text PDFThis work reports the application of a voltammetric electronic tongue (ET) towards the simultaneous determination of both nitro-containing and peroxide-based explosive compounds, two families that represent the vast majority of compounds employed either in commercial mixtures or in improvised explosive devices. The multielectrode array was formed by graphite, gold and platinum electrodes, which exhibited marked mix-responses towards the compounds examined; namely, 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), pentaerythritol tetranitrate (PETN), 2,4,6-trinitrotoluene (TNT), N-methyl-N,2,4,6-tetranitroaniline (Tetryl) and triacetone triperoxide (TATP). Departure information was the set of voltammograms, which were first analyzed by means of principal component analysis (PCA) allowing the discrimination of the different individual compounds, while artificial neural networks (ANNs) were used for the resolution and individual quantification of some of their mixtures (total normalized root mean square error for the external test set of 0.
View Article and Find Full Text PDFOver the last years, there has been an increasing demand for fast, highly sensitive and selective methods of analysis to meet new challenges in environmental monitoring, food safety and public health. In response to this demand, biosensors have arisen as a promising tool, which offers accurate chemical data in a timely and cost-effective manner. However, the difficulty to obtain sensors with appropriate selectivity and sensitivity for a given analyte, and to solve analytical problems which do not require the quantification of a certain analyte, but an overall effect on a biological system (e.
View Article and Find Full Text PDFCell microarrays are a novel platform for the high throughput discovery of new biomaterials. By re-creating a multitude of cell microenvironments on a single slide, this approach can identify the optimal surface composition to drive a desired cell response. To systematically study the effects of molecular microenvironments on stem cell fate, we designed a cell microarray based on parallel exposure of mesenchymal stem cells (MSCs) to surface-immobilised collagen I (Coll I) and bone morphogenetic protein 2 (BMP 2).
View Article and Find Full Text PDFIn this work, protein phosphatase inhibition assays (PPIAs) have been used to evaluate the performance of recombinant PP1 and recombinant and wild-type PP2As. The enzymes have been compared using microcystins-LR (MC-LR) as a model cyanotoxin. Whereas PP2ARec provides a limit of detection (LOD) of 3.
View Article and Find Full Text PDFThis paper reports the development of three peptide modified sensors in which glutathione (GSH) and its fragments Cys-Gly and γ-Glu-Cys were immobilized respectively through aryl diazonium electrochemical grafting onto the surface of graphite-epoxy composite electrodes (GEC), and used for the simultaneous determination of Cd(II), Pb(II) and Zn(II). The concentration interval ranged from 0.1 to 1.
View Article and Find Full Text PDFData processing techniques and measuring protocol are very important parts of the multisensor systems methodology. Complex analytical tasks like resolving the mixtures of two components with very similar chemical properties require special attention. We report on the application of non-linear (artificial neural networks, ANNs) and linear (projections on latent structures, PLS) regression techniques to the data obtained from the flow cell with potentiometric multisensor detection of neighouring lanthanides in the Periodic System of the elements (samarium, europium and gadolinium).
View Article and Find Full Text PDFIn this work, an electronic tongue (ET) system based on an array of potentiometric ion-selective electrodes (ISEs) for the discrimination of different commercial beer types is presented. The array was formed by 21 ISEs combining both cationic and anionic sensors with others with generic response. For this purpose beer samples were analyzed with the ET without any pretreatment rather than the smooth agitation of the samples with a magnetic stirrer in order to reduce the foaming of samples, which could interfere into the measurements.
View Article and Find Full Text PDFThe simultaneous determination of three nitro-containing compounds found in the majority of explosive mixtures, namely hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT) and pentaerythritol tetranitrate (PETN), is demonstrated using both qualitative and quantitative approaches involving the coupling of electrochemical measurements and advanced chemometric data processing. Voltammetric responses were obtained from a single bare screen-printed carbon electrode (SPCE), which exhibited marked mix-responses towards the compounds examined. The responses obtained were then preprocessed employing discrete wavelet transform (DWT) and the resulting coefficients were input to an artificial neural network (ANN) model.
View Article and Find Full Text PDFWe demonstrate a novel system for the detection and discrimination of varying levels of exposure to gunshot residue from subjects in various control scenarios. Our aim is to address the key challenge of minimizing the false positive identification of individuals suspected of discharging a firearm. The chemometric treatment of voltammetric data from different controls using Canonical Variate Analysis (CVA) provides several distinct clusters for each scenario examined.
View Article and Find Full Text PDFThis work reports the application of a BioElectronic Tongue (BioET) in the estimation of polyphenol content in wine. The approach used an array of enzyme biosensors capable of giving a wide and complete response of the analyzed species, plus a chemometric processing tool able to interpret the chemical signals and extract meaningful data from the complex readings. In our case, the proposed BioET was formed by an array of four voltammetric enzymatic biosensors based on epoxy-graphite composites, one blank electrode and the other three bulk-modified with tyrosinase and laccase on one side, and copper nanoparticles on the other; these modifiers were used in order to incorporate differentiated or catalytic response to different polyphenols present in wine and aimed to the determination of its total polyphenol content value.
View Article and Find Full Text PDFThis work reports the application of a Bio-Electronic Tongue (BioET) system made from an array of enzymatic biosensors in the analysis of polyphenols, focusing on major polyphenols found in wine. For this, the biosensor array was formed by a set of epoxy-graphite biosensors, bulk-modified with different redox enzymes (tyrosinase and laccase) and copper nanoparticles, aimed at the simultaneous determination of the different polyphenols. Departure information was the set of voltammograms generated with the biosensor array, selecting some characteristic features in order to reduce the data for the Artificial Neural Network (ANN).
View Article and Find Full Text PDF