Publications by authors named "Wuu C"

Purpose: To determine if MRI-based synthetic CTs (sCT), generated with no predefined pulse sequence, can be used for inhomogeneity correction in routine gamma knife radiosurgery (GKRS) treatment planning dose calculation.

Methods: Two sets of sCTs were generated from T1post and T2 images using cycleGAN. Twenty-eight patients (18 training, 10 validation) were retrospectively selected.

View Article and Find Full Text PDF

Background: Stereotactic radiosurgery (SRS) is a widely employed strategy for intracranial metastases, utilizing linear accelerators and volumetric modulated arc therapy (VMAT). Ensuring precise linear accelerator performance is crucial, given the small planning target volume (PTV) margins. Rapid dose falloff is vital to minimize brain radiation necrosis.

View Article and Find Full Text PDF

Validation of biodosimetry assays is routinely performed using primarily orthovoltage irradiators at a conventional dose rate of approximately 1 Gy/min. However, incidental/ accidental exposures caused by nuclear weapons can be more complex. The aim of this work was to simulate the DNA damage effects mimicking those caused by the detonation of a several kilotons improvised nuclear device (IND).

View Article and Find Full Text PDF

Purpose: Dose computation using cone beam computed tomography (CBCT) images is inaccurate for the purpose of adaptive treatment planning. The main goal of this study is to assess the dosimetric accuracy of synthetic computed tomography (CT)-based calculation for adaptive planning in the upper abdominal region. We hypothesized that deep learning-based synthetically generated CT images will produce comparable results to a deformed CT (CTdef) in terms of dose calculation, while displaying a more accurate representation of the daily anatomy and therefore superior dosimetric accuracy.

View Article and Find Full Text PDF

Purpose: Two-dimensional (2D) IMRT QA has been widely performed in Radiation Oncology clinic. However, concerns regarding its sensitivity in detecting delivery errors and its clinical meaning have been raised in publications. In this study, a robust methodology of three-dimensional (3D) IMRT QA using fiducial registration and structure-mapping was proposed to acquire organ-specific dose information.

View Article and Find Full Text PDF

Purpose: Recently a novel radiochromic sheet dosimeter, termed as PRESAGE sheets, consisting of leuco crystal violet dye and radical initiator had been developed and characterized. This study examines the dosimeter's temporal stability and storage temperature dependence postirradiation, and its applicability for dose verification in three dimensions (3D) as a stack dosimeter.

Methods: PRESAGE sheets were irradiated using 6 MV photons at a dose range of 0-20 Gy with the change in optical density measured using a flatbed scanner.

View Article and Find Full Text PDF

Purpose: A novel radiochromic PRESAGE sheet (Heuris Inc.) with 3 mm thickness has been developed as a measurement tool for 2D dosimetry. Its inherent ability to conform to irregular surfaces makes this dosimeter advantageous for patient surface dosimetry.

View Article and Find Full Text PDF

Objective: Investigate the temporal effects of focused ultrasound (FUS)-induced blood-brain barrier (BBB) opening in post-radiotherapy mouse brains.

Methods And Materials: C57B6 mice without tumors were used to simulate the scenario after gross total resection (GTR) of brain tumor. Radiation dose of 6 Gy x 5 was delivered to one-hemisphere of the mouse brain.

View Article and Find Full Text PDF

Purpose: To perform a three-dimensional (3D) concurrent isocentricity measurement of a clinical linear accelerator's (linac) using a single 3D dosimeter, PRESAGE.

Methods: A 3D dosimeter, PRESAGE, set up on the treatment couch of a Varian TrueBeam LINAC using the setup lasers, was irradiated under gantry angles of 0 , 50 , 160 , and 270 with the couch fixed at 0 and subsequently, under couch angles of 10 , 330 , 300 , and 265 with the gantry fixed at 270 . The 1 cm (at 100 cm SAD) square fields were delivered at 6 MV with 800 MU/field.

View Article and Find Full Text PDF

Background: Cytomegalovirus (CMV) infection is a serious complication in immunosuppressed patients, specifically transplant recipients. Here, we describe the development and use of an assay to monitor the incidence and treatment of CMV viremia in a Cynomolgus macaque model of bone marrow transplantation (BMT) for tolerance induction. We address the correlation between the course of viremia and immune reconstitution.

View Article and Find Full Text PDF

Purpose: Cone beam computed tomography (CBCT) imaging has been implemented on the Leksell Gamma Knife Icon™ for assessing patient positioning in mask-based Gamma Knife radiosurgery. The purpose of this study was to evaluate the performance of the CBCT-based patient positioning system as a tool for frameless Gamma Knife radiosurgery.

Methods: Daily quality assurance (QA) CBCT precision test results from a 12-month period were analyzed for the geometric accuracy and the stability of the imager.

View Article and Find Full Text PDF

Purpose: Cherenkov light emission has been shown to correlate with ionizing radiation dose delivery in solid tissue. An important clinical application of Cherenkov light is the real-time verification of radiation treatment delivery in vivo. To test the feasibility of treatment field verification, Cherenkov light images were acquired concurrent with radiation beam delivery to standard and anthropomorphic phantoms.

View Article and Find Full Text PDF

In recent years, small animal image-guided irradiators have been widely utilized in preclinical studies involving rodent models. However, the dosimetry commissioning of such equipment involving kilovoltage small-field dosimetry has not received as much interest as the megavoltage small-field dosimetry used clinically. To date, a paucity of measured kilovoltage beam data, especially for field sizes less than 3 mm, can be found in the literature.

View Article and Find Full Text PDF

Purpose: To implement Velocity-based image fusion and adaptive deformable registration to enable treatment planning for preclinical murine models of fractionated stereotactic radiosurgery (fSRS) using the small animal radiation research platform (SARRP).

Methods And Materials: C57BL6 mice underwent 3 unique cone beam computed tomography (CBCT) scans: 2 in the prone position and a third supine. A single T1-weighted post-contrast magnetic resonance imaging (MRI) series of a murine metastatic brain tumor model was selected for MRI-to-CBCT registration and gross tumor volume (GTV) identification.

View Article and Find Full Text PDF

Purpose: The precise dosimetric and geometric characteristics of small animal irradiators are essential to achieving reproducible dose delivery, especially in cases where image-guidance is utilized. Currently, radiochromic film is the established measurement tool used to evaluate beam characteristics for these systems. However, only 2D information can be acquired with film.

View Article and Find Full Text PDF

Purpose: To establish a novel preclinical model for stereotactic radiosurgery (SRS) with combined mouselike phantom quality assurance in the setting of brain metastases.

Methods And Materials: C57B6 mice underwent intracranial injection of B16-F10 melanoma cells. T1-weighted postcontrast magnetic resonance imaging (MRI) was performed on day 11 after injection.

View Article and Find Full Text PDF

The introduction of advanced techniques and technology in radiotherapy has greatly improved our ability to deliver highly conformal tumor doses while minimizing the dose to adjacent organs at risk. Despite these tremendous improvements, there remains a general concern about doses to normal tissues that are not the target of the radiation treatment; any "nontarget" radiation should be minimized as it offers no therapeutic benefit. As patients live longer after treatment, there is increased opportunity for late effects including second cancers and cardiac toxicity to manifest.

View Article and Find Full Text PDF

Background: Infusion of recipient regulatory T (Treg) cells promotes durable mixed hematopoietic chimerism and allograft tolerance in mice receiving allogeneic bone marrow transplant (BMT) with minimal conditioning. We applied this strategy in a Cynomolgus macaque model.

Methods: CD4 CD25 Treg cells that were polyclonally expanded in culture were highly suppressive in vitro and maintained high expression of FoxP3.

View Article and Find Full Text PDF

An intraoperative radiation therapy (IORT) device with 50 kV X rays was designed to deliver a single dose to the tumour bed after local excision of breast cancer. The quality of a radiation can be determined by the microscopic distribution of energy transfers along and across the charged particle tracks. The lineal energy, y, serves as an accurate measure of local energy concentration.

View Article and Find Full Text PDF

We examined the fetal dose from irradiation of glioblastoma during pregnancy using intensity modulated radiation therapy (IMRT), and describe fetal dose minimization using mobile shielding devices. A case report is described of a pregnant woman with glioblastoma who was treated during the third trimester of gestation with 60 Gy of radiation delivered via a 6 MV photon IMRT plan. Fetal dose without shielding was estimated using an anthropomorphic phantom with ion chamber and diode measurements.

View Article and Find Full Text PDF

Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner.

View Article and Find Full Text PDF

Purpose: To prospectively evaluate a 2-dimensional transit dosimetry algorithm's performance on a patient population and to analyze the issues that would arise in a widespread clinical adoption of transit electronic portal imaging device (EPID) dosimetry.

Methods And Materials: Eleven patients were enrolled on the protocol; 9 completed and were analyzed. Pretreatment intensity modulated radiation therapy (IMRT) patient-specific quality assurance was performed using a stringent local 3%, 3-mm γ criterion to verify that the planned fluence had been appropriately transferred to and delivered by the linear accelerator.

View Article and Find Full Text PDF

The performance of a fast optical computed tomography (CT) scanner based on a point laser source, a small area photodiode detector, and two optical-grade Fresnel lenses is evaluated. The OCTOPUS™-10× optical CT scanner (MGS Research Inc., Madison, CT) is an upgrade of the OCTOPUS™ research scanner with improved design for faster motion of the laser beam and faster data acquisition process.

View Article and Find Full Text PDF

Purpose: A method to perform transit dosimetry with an electronic portal imaging device (EPID) by extending the commercial implementation of a published through-air portal dose image (PDI) prediction algorithm Van Esch et al. [Radiother. Oncol.

View Article and Find Full Text PDF