Background: To investigate the long-term efficacy of the paclitaxel-eluting Legflow balloon catheter in the treatment of "real-world" long and complex femoropopliteal lesions.
Methods: The REFLOW study was a prospective, multi-national, non-randomized, single arm study evaluating the long-term safety and efficacy of the Legflow paclitaxel-eluting balloon dilatation catheter in the treatment of stenotic or occlusive lesions >150 mm long in the femoropopliteal arteries of symptomatic patients (Rutherford 2-5). A total of 120 study subjects were enrolled in a period of 30 months, between October 2015 and May 2018.
Hepatic artery aneurysms (HAAs) are rare vascular malformations that can arise from atherosclerosis, trauma, or iatrogenic injury. HAAs can be symptomatic and lead to serious complications. We present the case of a patient with painless jaundice caused by obstruction of the distal common bile duct by a HAA on a replaced right hepatic artery.
View Article and Find Full Text PDFPurpose: This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures.
Materials And Methods: All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion).
Purpose: To report the 60-month safety and effectiveness results of a multicenter, prospective, randomized controlled trial comparing the ZILVER PTX paclitaxel-eluting stent to prosthetic above-the-knee bypass for the treatment of symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions.
Materials And Methods: Patients were enrolled between October 2013 and July 2017. One of the secondary outcomes was primary patency at 60 months, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex ultrasound peak systolic velocity ratio < 2.
Objectives: To prove that the ELVeS® Radial® 2ring slim fiber (Biolitec AG, Wien, Austria) is safe and effective, with a reliable fiber durability.
Methods: This prospective, non-randomized, registry recruited patients with venous incompetence of the great saphenous vein, with or without concomitant incompetence of the small, anterior accessory and posterior accessory saphenous veins. Anatomic success, clinical success and pain were assessed.
Background: To report the 3-year safety and effectiveness results of a multicenter, prospective, randomized controlled trial comparing the ZILVER PTX paclitaxel-eluting stent to surgical bypass and to conduct a health economic analysis up to 3-year follow-up of the two treatment modalities.
Methods: This is a study in symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions comparing endovascular ZILVER PTX stenting vs. surgical bypass surgery using a prosthetic graft (ClinicalTrials.
Objective: To investigate access failure (AF) and stroke rates of aortic procedures performed with upper extremity access (UEA), and compare results of open surgical vs. percutaneous UEA techniques with closure devices.
Methods: A physician initiated, multicentre, ambispective, observational registry (SUPERAXA - NCT04589962) was carried out of patients undergoing aortic procedures requiring UEA, including transcatheter aortic valve replacement, aortic arch, and thoraco-abdominal aortic endovascular repair, pararenal parallel grafts, renovisceral and iliac vessel repair.
Background: The aim of the study was to demonstrate the safety and effectiveness of a suture-mediated vascular closure device to perform hemostasis after an axillary artery access during endovascular procedures on the aortic valve, the aorta and its side branches.
Methods: A physician-initiated, international, multicenter, retrospective registry was designed to evaluate the success rate (VARC-2 reporting standards) of percutaneous transaxillary access closure with a suture-mediated closure device. Secondary end points were minor access vascular complications, transient peripheral nerve injury, stroke, and influence on periprocedural outcomes of puncture technique.
Background: The aim of this study is to investigate the efficacy of the paclitaxel-eluting Legflow balloon catheter in the treatment of "real-world" long and complex femoropopliteal lesions.
Methods: The REFLOW study was a prospective, multi-national, non-randomized, single arm study evaluating the safety and efficacy of the Legflow paclitaxel-eluting balloon dilatation catheter in the treatment of stenotic or occlusive lesions >150 mm long in the femoropopliteal arteries of symptomatic patients (Rutherford 2-5). A total of 120 study subjects were enrolled in a period of 30 months, between October 2015 and May 2018.
Background: The aim of this study was to investigate the efficacy of the balloon expandable Promus Element and Promus Element Plus stents (both Boston Scientific, Marlborough, MA, USA), coated with everolimus, in the treatment of short, focal infrapopliteal lesions.
Methods: The PREVENT study was a prospective, multicenter, non-randomized, single arm study evaluating the safety and efficacy of the Promus Element and Promus Element Plus stent in the treatment of stenotic or occlusive lesions ≤40 mm long in the tibioperoneal arteries of patients with critical limb ischemia (CLI). A total of 70 study subjects were enrolled in a period of 26 months, between November 2012 and December 2014.
Background: The EVOLUTION Study is a prospective, non-randomized study, investigating the iVolution stent (iVascular, Barcelona, Spain). The study was conducted at the vascular departments of four hospitals in Belgium. This manuscript reports the findings up to 12-month follow-up time for the total cohort.
View Article and Find Full Text PDFBackground: The BeGraft Peripheral PMCF study is a prospective, non-randomized study, conducted at the vascular departments of 4 hospitals in Belgium. This manuscript reports the findings up to 12-month follow-up time for the total cohort. The primary endpoint of the study is primary patency at 12 months.
View Article and Find Full Text PDFBackground Cockett and Thomas described and named Cockett's syndrome in 1965, commonly referred to as iliac vein compression syndrome (IVCS). It is often found as underlying cause in iliofemoral deep venous thrombosis (DVT). They described the syndrome mostly seen on the left side and predominantly in women during the second to the fourth decade of life.
View Article and Find Full Text PDF