Statement Of Problem: Characterizing interim restorations promotes esthetics. However, studies on the effects of characterization materials on the surface roughness and gloss of interim materials after toothbrushing are lacking.
Purpose: The purpose of this in vitro study was to evaluate the surface roughness and gloss of 5 different interim materials with different surface treatments after 1 year of simulated toothbrushing.
Background: Digitally fabricated dentures may require relining due to continual alveolar ridge resorption. However, studies evaluating the tensile bond strength (TBS) of digitally fabricated dentures bonded to denture liners are lacking. This study aimed to evaluate the TBS of autopolymerized, heat-polymerized, milled, and 3D printed denture base materials bonded to 2 acrylic-based and 2 silicone-based denture liners, both before and after thermocycling.
View Article and Find Full Text PDFStatement Of Problem: Dental implants are particularly susceptible to occlusal overloading because, unlike natural teeth, they lack a periodontal ligament to help absorb occlusal forces. However, studies evaluating the impact of different crown and luting materials on the damping behavior and strain distribution of implant-supported crowns are lacking.
Purpose: The purpose of this in vitro study was to investigate the damping behavior and strain distribution of peri-implant bone associated with 5 different CAD-CAM implant-supported crowns and 3 luting materials.
Aim: To compare the removal torque loss (RTL) percentage of screw-retained, cement-retained, and combined screw- and cement-retained implant-supported crowns after cyclic loading and measure the impact of cyclic loading on removal torque.
Materials And Methods: Thirty-two dental implants (4.0 × 10 mm) in resin blocks and abutments were divided into four groups ( = 8) based on restoration design: combined screw- and cement-retained group (SC), two cement-retained groups: cemented with adhesive resin cement (AR) (Panavia V5) or provisional cement (PR) (RelyX Temp NE), and screw-retained one-piece titanium group (TI).
This study aimed to evaluate the thermocycling effect on the retentive force of 3 different retentive inserts in 3 denture attachments (Blue, Pink, Clear retentive inserts in LOCATOR; Blue, Pink, Clear retentive inserts in LOCATOR R-Tx; and White, Yellow, Green retentive inserts in Novaloc) (n=10). Maximum retentive force of each retentive insert was evaluated at baseline, 7-day water storage, and after 5,000-, and 10,000- cycle thermocycling. The water absorption percentage of the retentive inserts was also determined.
View Article and Find Full Text PDFStatement Of Problem: Daily denture brushing results in wear on implant-retained overdenture attachments. However, studies on the remaining denture attachment retention after brushing are lacking.
Purpose: The purpose of this in vitro study was to evaluate the retentive force of the retentive inserts in 3 denture attachments after brushing with different media.
This study evaluated the antifungal, physical, and mechanical properties of tissue conditioner incorporated with different amounts of zinc oxide nanoparticles (ZnOnps) at different storage times (0, 7, and 14 days). Specimens of 0, 5, 10, 15 wt% ZnOnps, or 15 wt% nystatin incorporated into tissue conditioner were fabricated (control, 5Zn, 10Zn, 15Zn, and Nys). The direct contact test (n=6) was performed to evaluate the antifungal effect against C.
View Article and Find Full Text PDF