Publications by authors named "Woo-Seong Tak"

Recently, the development of medical rehabilitation technology has resulted in an increased interest in speech therapy equipment. In particular, research on articulation therapy for communication disorders is being actively conducted. The existing methods for the diagnosis and treatment of speech disorders, such as traditional tactile perception tests and methods based on the empirical judgment of speech therapists, have many limitations.

View Article and Find Full Text PDF

Graphene reinforced aluminum matrix composites (GRAMCs) with improved thermal conductivity were prepared via a pH-controlled self-assembly process that involved adjusting the concentration of dispersed graphene oxide (GO) solutions. Uniform dispersion was achieved using GO coating on the aluminum (Al) surfaces. Graphene encapsulated Al powders (Al/GO) were sintered through spark plasma sintering (SPS) to prepare bulk composites, these were then analyzed to determine the thermal and mechanical properties.

View Article and Find Full Text PDF

In step with the development of Industry 4.0, research on automatic operation technology and components related to automobiles is continuously being conducted. In particular, the torque angle sensor (TAS) module of the steering wheel system is considered to be a core technology owing to its precise angle, torque sensing, and high-speed signal processing.

View Article and Find Full Text PDF

Microphones for hearing aid systems are required to have high sensitivity, an appropriate bandwidth, and a wide dynamic range. In this paper, a high sensitivity microphone, 4 mm in diameter and using a multilayer graphene-PMMA laminated diaphragm that can be applied in hearing aids, is designed, optimized, and implemented. Typically, polyphenylene sulfide (PPS) has been used for the diaphragm of electret condenser microphones (ECM), and this method provides simple, low cost mass production.

View Article and Find Full Text PDF

Many types of fully implantable hearing aids have been developed. Most of these devices are implanted behind the ear. To maintain the implanted device for a long period of time, a rechargeable battery and wireless power transmission are used.

View Article and Find Full Text PDF

Fully implantable hearing devices (FIHDs) have been developed as a new technology to overcome the disadvantages of conventional acoustic hearing aids. The implantable microphones currently used in FIHDs, however, have difficulty achieving high sensitivity to environmental sounds, low sensitivity to body noise, and ease of implantation. In general, implantable microphones may be placed under the skin in the temporal bone region of the skull.

View Article and Find Full Text PDF

The microphone in a fully implantable hearing device (FIHD) is generally implanted under the skin covering the temporal bone. However, the implanted microphone can be affected by the skin, which causes both sound attenuation and distortion, particularly at high frequencies. As the degree of attenuation and distortion through the skin is severe, speech quality evaluation parameters are needed for the received signal when designing an implantable microphone.

View Article and Find Full Text PDF

Input for fully implantable hearing devices (FIHDs) is provided by an implantable microphone under the skin of the temporal bone. However, the implanted microphone can be affected when the FIHDs user chews. In this paper, a dual implantable microphone was designed that can filter out the noise from mastication.

View Article and Find Full Text PDF

With the advent of implantable hearing aids, implementation and acoustic sensing strategy of the implantable microphone becomes an important issue; among the many types of implantable microphone, placing the microphone in middle ear cavity (MEC) has advantages including simple operation and insensitive to skin touching or chewing motion. In this paper, an implantable microphone was implemented and researched feedback characteristic when both the implantable microphone and the transducer were placed in the MEC. Analytical and finite element analysis were conducted to design the microphone to have a natural frequency of 7 kHz and showed good characteristics of SNR and sensitivity.

View Article and Find Full Text PDF