Publications by authors named "Woo-Hyuk Lee"

Purpose: To identify how the inner retinal layer and microvasculature change with age by analyzing the relationships of ganglion cell-inner plexiform layer (GC-IPL) thickness, vessel density (VD), and the ratio of these measurements with age in healthy eyes.

Methods: Participants were divided into five groups according to age. The GC-IPL thickness, VD, and GC-IPL/VD ratio were compared among the groups.

View Article and Find Full Text PDF

Spectral-domain optical coherence tomography (SD-OCT) must accurately identify and measure the peripapillary retinal nerve fiber layer (pRNFL) thickness to improve the repeatability and reproducibility, and reduce measurement errors. Because Weiss ring can be located in front of the optic disc, we hypothesized that it may affect pRNFL thickness measurements obtained using SD-OCT. We retrospectively reviewed the medical records of patients with (group W) and without (group N) Weiss ring, observed on OCT fundus image and an RNFL map devised using SD-OCT.

View Article and Find Full Text PDF

In this work, a cerium/tetraethylenepentamine dithiocarbamate complex was synthesized and evaluated for the corrosion inhibition capability on an AA2024-T3 Al alloy in a 3.5% NaCl medium. The synthesized compounds were characterized via spectroscopic techniques.

View Article and Find Full Text PDF
Article Synopsis
  • - This study assessed the repeatability of peripapillary optical coherence tomography angiography (OCTA) measurements in healthy eyes, involving 84 participants with no significant eye diseases or surgeries.
  • - Short-term repeatability showed a coefficient of variation (CV) of 2.94-4.22% and an intraclass correlation coefficient (ICC) between 0.840-0.934, while long-term repeatability indicated a CV of 2.73-3.84% and an ICC of 0.737-0.934.
  • - The findings revealed that axial length and mean signal strength significantly influence long-term repeatability, highlighting the need to consider these factors when analyzing OCTA images in research or
View Article and Find Full Text PDF

Objective: To investigate the effects of axial length (AL) on the peripapillary microvascular density acquired from optical coherence tomography angiography (OCTA).

Methods: Retrospective observational study. A total of 111 eyes from 111 normal healthy subjects were examined.

View Article and Find Full Text PDF

A new approach to the recycling of spent coffee grounds is described in which lignin, a chemical component of spent coffee, is used as an electrolyte additive in aluminum-air batteries. The effect of lignin on the performance of aluminum-air batteries has been investigated by weight loss measurement, galvanostatic discharge test, and electrochemical impedance spectroscopy (EIS). The corrosion inhibition efficiency is improved up to 37.

View Article and Find Full Text PDF

Rationale: Several reports have described retinal pigment epithelial (RPE) tears in central serous chorioretinopathy (CSC). However, there have been no reports of spontaneously large RPE tears in acute CSC without bullous retinal detachment (RD). Herein, we report and provide sequential images of a case of bilateral spontaneous large RPE tears in patient with acute CSC without bullous RD.

View Article and Find Full Text PDF

Background: We aimed to study the bilateral choroidal thickness (CT) symmetry and difference in uncomplicated pachychoroid subjects using wide-field swept-source optical coherence tomography (SS-OCT).

Methods: All subjects underwent a wide-field 16-mm one-line scan using SS-OCT. Bilateral CT was measured at, and compared among, the following 12 points: three points at 900-µm intervals from the nasal optic disc margin (nasal peripapillary area), one point at the subfovea, six points at 900-µm intervals from the fovea to the nasal and temporal areas (macular area), and two peripheral points 5400 and 8100 µm from the fovea (peripheral area).

View Article and Find Full Text PDF

Purpose: To identify the impact of hypertension (HTN) on macular microvasculature in type 2 diabetes (T2DM) patients without clinical diabetic retinopathy.

Methods: In this retrospective cross-sectional study, subjects were divided into three groups: controls (control group), patients with T2DM (DM group), and patients with both T2DM and HTN (DM + HTN group). The vessel length density (VD) was compared among the groups.

View Article and Find Full Text PDF

Type 2 diabetes mellitus (T2DM) and hypertension (HTN) are both relatively common systemic diseases and cause damage to the retina, such as inner retina reduction and microvascular impairment. The purpose of this study was to identify peripapillary retinal nerve fiber layer (pRNFL) damage by diabetic neurodegeneration and the effects of HTN on the pRNFL thickness in patients with T2DM without clinical diabetic retinopathy. Subjects were divided into three groups: healthy control subjects (group 1), patients with T2DM (group 2), and patients with both diabetes and HTN (group 3).

View Article and Find Full Text PDF

This study aimed to quantify the Haller vessel and choriocapillaris (CC) parameters in drusen subtypes in nonexudative age-related macular degeneration (AMD) and pachydrusen. Ninety-five eyes of 80 patients and 28 control eyes were categorized into soft drusen, subretinal drusenoid deposit (SDD), soft drusen plus SDD, pachydrusen, and control groups. The diameter, length and intersections of Haller vessels and the total area, size and number of CC flow voids were quantified using en face optical coherence tomography (OCT) or OCT angiography.

View Article and Find Full Text PDF

The Bruch's membrane opening-minimum rim width (BMO-MRW) is a recently introduced parameter of the neuroretinal rim. We analyzed the repeatability of spectral-domain optical coherence tomography (SD-OCT) measurements of BMO-MRW in epiretinal membrane (ERM) patients with peripapillary involvement, since the surface around the optic disc is distorted in such patients. BMO-MRW and retinal nerve fiber layer (RNFL) thickness measurements were performed using SD-OCT in prospectively enrolled ERM patients and age-matched healthy control individuals.

View Article and Find Full Text PDF
Article Synopsis
  • High sensitivity detection of tumor markers like vascular endothelial growth factor (VEGF) is crucial for quick cancer diagnosis and treatment.
  • An electrochemical aptasensor utilizing nanocomposites of polyaniline (PANI) and carbon nanotubes (CNT) shows promise due to its cost-effectiveness and quantitative capabilities.
  • This aptasensor can detect VEGF at very low concentrations (as low as 0.4 pg/mL) and maintains stability and reproducibility, making it suitable for future non-invasive diagnostic applications.
View Article and Find Full Text PDF

Purpose: Acute and chronic hypertension may have different pathophysiological mechanisms in the retina. Here, we compared the retinal nerve fibre layer (RNFL)/ganglion cell-inner plexiform layer (GC-IPL) thickness ratios of patients with 'relieved' severe hypertensive retinopathy (relieved HTNR) and chronic hypertension without retinopathy (chronic HTN) to those of normal controls.

Methods: We performed cross-sectional study.

View Article and Find Full Text PDF

Purpose: It is hypothesized that an unstable tear film would affect the quality and repeatability of optical coherence tomography angiography (OCTA). Therefore, OCTA repeatability according to tear break-up time (TBUT) was compared.

Methods: The 3 × 3 OCTA was performed twice and, the eyes were divided into 3 groups according to the TBUT (Group 1: TBUT ≤ 5 seconds, 43 eyes; Group 2: 5 seconds < TBUT ≤ 10 seconds, 35 eyes; Group 3: TBUT > 10 seconds, 34 eyes).

View Article and Find Full Text PDF

Purpose: The purpose of this study to identify the effects of prolonged type 2 diabetes (T2DM) on the peripapillary retinal nerve fiber layer (pRNFL) and peripapillary microvasculature in patients with prolonged T2DM without clinical diabetic retinopathy (DR).

Methods: Subjects were divided into 3 groups: controls (control group; 153 eyes), patients with T2DM < 10 years (DM group 1; 136 eyes), and patients with T2DM ≥ 10 years (DM group 2; 74 eyes). The pRNFL thickness and peripapillary superficial vessel density (VD) were compared.

View Article and Find Full Text PDF

Purpose: The purpose of this paper was to study the bilateral choroidal thickness (CT) symmetry and differences in healthy individuals using wide-field swept-source optical coherence tomography (SS-OCT).

Methods: All participants underwent a wide-field 16-mm 1-line scan using SS-OCT. CTs were measured at the following 12 points: 3 points at 900 µm, 1800 µm, and 2700 µm away from the nasal optic disc margin (nasal peripapillary area), 1 point at the subfovea, 6 points at 900 µm, 1800 µm, and 2700 µm away from the subfovea to the nasal and temporal areas (macular area), and 2 peripheral points at 2700 and 5400 µm from temporal point 3 (peripheral area).

View Article and Find Full Text PDF

Rationale: A few cases of optic neuropathy presumed to be caused by vincristine have been reported. However, none described multimodal imaging findings. Here, we report abnormal magnetic resonance imaging (MRI) and optical coherence tomography (OCT) findings in a putative case of vincristine-induced optic neuropathy.

View Article and Find Full Text PDF

Objective: To investigate the thicknesses of the ganglion cell-inner plexiform layer (GC-IPL) and retinal nerve fiber layer (RNFL) of the fellow eyes of patients with unilateral exudative age-related macular degeneration (AMD).

Methods: A total of 107 patients with unilateral exudative AMD [34 of typical choroidal neovascularization (tCNV), Group A; 73 of polypoidal choroidal vasculopathy (PCV), Group B] and 73 normal control eyes (Group C) were included. Drusen and subretinal drusenoid deposits were assessed in all participants using fundus photography, autofluorescence, and optical coherence tomography (OCT).

View Article and Find Full Text PDF

Purpose: To investigate the association between myopia and peripapillary retinal nerve fiber layer (pRNFL) thickness in diabetic patients without diabetic retinopathy (DR).

Methods: A total of 271 eyes of 271 participants were included. They were divided into four groups according to the presence of myopia (≤ -3 diopters [D]) and diabetes without DR: (1) control group (n = 76), (2) myopia group (n = 57), (3) diabetes group (n = 82), and (4) diabetes + myopia group (n = 56).

View Article and Find Full Text PDF

Purpose: We investigated the wide-field choroidal thickness (CT) using swept-source optical coherence tomography (SS-OCT) and compared the characteristics of the choroidal layer between pachychoroid and normochoroid groups.

Methods: A total of 120 eyes from 120 normal subjects were included. All subjects were divided into two groups according to the subfoveal CT (≥300 μm, pachychoroid group; <300μm, normochoroid group).

View Article and Find Full Text PDF

Purpose: To identify the effects of prolonged type 2 diabetes (T2DM) on macular microcirculation and the inner retinal layer in diabetic eyes without clinical diabetic retinopathy (DR).

Methods: 97, 92, and 57 eyes in the control, patients with T2DM < 10 years (DM group one), and patients with T2DM ≥ 10 years (DM group two) were enrolled. The ganglion cell-inner plexiform layer (GC-IPL) thickness and superficial vessel density (VD) were compared.

View Article and Find Full Text PDF

To analyze longitudinal changes in peripapillary retinal nerve fiber layer (pRNFL) thicknesses over time in the fellow eyes of patients with unilateral retinal vein occlusion (RVO). A total of 47 patients with unilateral RVO and 47 healthy controls were enrolled. The mean and sectoral pRNFL thicknesses were measured using spectral domain-optical coherence tomography at 1 year intervals, and followed for 3 years.

View Article and Find Full Text PDF

The purpose of this study was to investigate changes in peripapillary microvasculature using optical coherence tomography angiography (OCTA) in systemic hypertension (HTN) patients. This was a cross-sectional study. Based on the duration of HTN, seventy-eight HTN patients were divided into two groups.

View Article and Find Full Text PDF

Purpose: To determine the comparability of choroidal thickness (ChT) measurements using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) devices in patients with pachychoroid diseases.

Methods: Patients with pachychoroid diseases were recruited. OCT scans were performed sequentially with a Cirrus HD OCT 5000 and Plex Elite 9000.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionq9o4qjno5q56ae7642dpbjr6ru7f4lv1): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once