Purpose: This pilot study investigated the effect of surface roughness on osseointegration by comparing two types of commercial SLA-treated dental implants with different surface roughness levels: moderately rough (S = 1 - 2 µm) and rough surfaces (S > 2 µm).
Materials And Methods: Two implant groups were studied: TS (rough surface) and ADD (moderately rough surface) groups. Surface characteristics were analyzed using optical profilometry and SEM.
Recent studies have explored surface treatments, such as increasing the hydrophilicity of implant fixtures, to enhance the osseointegration of implants. This prospective clinical study aimed to assess the clinical stability and efficacy of plasma treatment applied to implants with sandblast-acid etching (SLA) surfaces before placement. Twenty-eight patients requiring implant placement provided consent and were assigned randomly to either the SLA group without plasma treatment or the SLA/plasma group with plasma treatment.
View Article and Find Full Text PDFPurpose: This study was conducted to evaluate the effects of plasma treatment of sandblasted and acid-etched (SLA) titanium implants on surface cleansing and osseointegration in a beagle model.
Materials And Methods: For morphological analysis and XPS analysis, scanning electron microscope and x-ray photoelectron spectroscopy were used to analyze the surface topography and chemical compositions of implant before and after plasma treatment. For this animal experiment, twelve SLA titanium implants were divided into two groups: a control group (untreated implants) and a plasma group (implants treated with plasma).
Purpose: This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP).
Materials And Methods: A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined.
Purpose: This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems.
Materials And Methods: Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2).
Purpose: An implant-supported prosthesis consists of an implant fixture, an abutment, an internal screw that connects the abutment to the implant fixture, and the upper prosthesis. Numerous studies have investigated the microorganisms present on the implant surface, surrounding tissues, and the subgingival microflora associated with peri-implantitis. However, there is limited information regarding the microbiome within the internal screw space.
View Article and Find Full Text PDFIn this study, hydroxypropyl methylcellulose (HPMC) was mixed with particle-type xenografts, derived from two different species (bovine and porcine), to increase the manipulability of bone grafts and compare the bone regeneration ability. Four circular defects with a diameter of 6 mm were formed on each rabbit calvaria, and the defects were randomly divided into three groups: no treatment (control group), HPMC-mixed bovine xenograft (Bo-Hy group), and HPMC-mixed porcine xenograft (Po-Hy group). At eight weeks, micro-computed tomography (µCT) scanning and histomorphometric analyses were performed to evaluate new bone formation within the defects.
View Article and Find Full Text PDFPurpose: The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models.
Materials And Methods: Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co.
The purpose of this study was to evaluate the bone-generating ability of a new bovine-derived xenograft (S1-XB) containing hydrogel. For control purposes, we used Bio-Oss and Bone-XB bovine-derived xenografts. S1-XB was produced by mixing Bone-XB and hydrogel.
View Article and Find Full Text PDFThis prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement.
View Article and Find Full Text PDFThis study aimed to compare two methods of crosslinking collagen type I on implanted titanium surfaces, that is, using glutaraldehyde (GA) or gamma-rays (GRs), in a beagle dog model. For in vivo experiments, implants were allocated to three groups and applied to mandibular bone defects in beagle dogs; Group SLA; non-treated Sandblasted, large grit, acid-etched (SLA) implants, Group GA; SLA implants coated with GA crosslinked collagen type I, Group GR; SLA surface implants coated with collagen type I and crosslinked using 25 kGy of Co gamma radiation. New bone μCT volumes were obtained, and histologic and histometric analyses were performed in regions of interest.
View Article and Find Full Text PDFThis retrospective clinical study was conducted to evaluate the clinical usefulness of a freely removable microlocking implant prosthesis (MLP) that was developed to overcome the problems with conventional implant prostheses. A total of 54 patients (male: 31, female: 23) and 100 implant prostheses were included. Patients were divided into three groups such as 6-12 months, 12-18 months, and 18-24 months according to the used period after implant prosthesis delivery, and the patients in each group were recalled for examinations of survival rate, marginal bone resorption, peri-implant soft tissue indices, and complications.
View Article and Find Full Text PDFThe purpose of this study was to evaluate the bone regeneration efficacy of an 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC)-cross-linked collagen membrane for guided bone regeneration (GBR). A non-cross-linked collagen membrane (Control group), and an EDC-cross-linked collagen membrane (Test group) were used in this study. In vitro, mechanical, and degradation testing and cell studies were performed.
View Article and Find Full Text PDFThe purpose of this study was to assess the clinical fit provided by EZIS system, the newly commercialized chairside CAD/CAM system. Prostheses were fabricated with the chairside CAD/CAM system (CS) and labside CAD/CAM system (LS) and marginal, axial, and occlusal fit of the prostheses were compared and analyzed by using replica technique. CS group presented significantly lower fit in all the three fits compared to LS group.
View Article and Find Full Text PDFA custom abutment produced from a digital scan can be used to develop an implant-supported prosthesis with ideal contours. A scan body is used to obtain information about the location of the implant fixture, and the scan body has a special scan region that facilitates superimposition. This dental technique indirectly obtains the margin of the definitive prosthesis by designing the special scan region on a custom abutment and superimposing prescanned abutment data onto intraoral scanned data.
View Article and Find Full Text PDFIt is important to obtain sufficient bone mass before implant placement on alveolar bone, and synthetic bone such as biphasic calcium phosphate (BCP) has been studied to secure this. This study used a BCP block bone with a specific structure of the three-dimensional (3D) hexahedron channel and coating with recombinant human bone morphogenetic protein-2 (rhBMP-2) impregnated carboxymethyl cellulose (CMC) was used to examine the enhancement of bone regeneration of this biomaterial in rat calvarial defect. After the preparation of critical-size calvarial defects in fifteen rats, defects were divided into three groups and were implanted with the assigned specimen (n = 5): Boneplant (untreated 3D hexahedron channeled BCP block), Boneplant/CMC (3D hexahedron channeled BCP block coated with CMC), and Boneplant/CMC/BMP (3D hexahedron channeled BCP block coated with CMC containing rhBMP-2).
View Article and Find Full Text PDFColibacillosis is one of the major health problems in young piglets resulting in poor health and death caused by producing F18 pili and Shiga toxin 2e. It is pivotal to reduce colibacillosis in weaned piglets to enhance production performance. In this study, we evaluated synbiotics as the gut health improvement agents in the mouse model challenged with Shiga toxin-producing (STEC) isolated from piglets.
View Article and Find Full Text PDFThe aim of this study was to evaluate the wear properties of opposed dental ceramic restorative CAD/CAM materials and several posterior direct restorative composite resins. Three kinds of dental ceramics CAD/CAM materials (monolithic zirconia, lithium disilicate, leucite) and four dental composite resins-that is, MI Gracefil, Gradia Direct P, Estelite Σ Quick, and Filtek Supreme Ultra-were used in this study. For each of the 12 groups (three ceramics × four composite resins), five each of a canine-shaped ceramic specimen and a cuboidal shape opposing composite resin were prepared.
View Article and Find Full Text PDF