Background: Chronic venous insufficiency (CVI) is a common disease with a high prevalence. Incompetent venous valves are considered as one of the main causes. Besides compression therapy, various surgical therapies are practiced, whereby the reconstruction of valves is of central importance.
View Article and Find Full Text PDFObjectives: The study investigated mechanical parameters of stent systems indicated for treatment of femoropopliteal (FP) arterial disease to support interpretation of clinical results and the related causalities.
Methods: Eight stent system types of same dimensions were investigated (n=2). Parameters were the profile of stent delivery system (SDS), radiopacity, trackability and pushability, bending stiffness (flexibility) and axial stiffness of expanded stents, length change during expansion, radial force, crush resistance, strut thickness and general surface condition.
Sleep is negatively affected by environmental noise. In the present study, we investigated self-reported high sleep disturbances (being "highly sleep disturbed"-HSD) from road traffic (primary and secondary road networks), rail (train and tram) and air traffic noise in the LIFE-Adult cohort study in Leipzig, Germany. For this, we used exposure data from 2012 and outcome data of Wave 2 (collected during 2018-2021).
View Article and Find Full Text PDFPurpose: Microinvasive glaucoma surgery (MIGS) has become an important treatment approach for primary open-angle glaucoma, although the safe and long-term effective lowering of intraocular pressure with currently available implants for MIGS is not yet achieved to a satisfactory extent. The study focusses on the development and in vitro and in vivo testing of a novel microstent for MIGS.
Methods: A silicone elastomer-based microstent was developed.
In the biomedical field, nanofiber materials are gaining increasing application. For material characterization of nanofiber fabrics, tensile testing and scanning electron microscopy (SEM) are established standards. However, tensile tests provide information about the entire sample without information about single fibers.
View Article and Find Full Text PDFBackground: Percutaneous coronary interventions (PCI) of bifurcation stenoses are both complex and challenging. Stenting strategies share that the stents' side cells must be carefully explored and appropriately prepared using balloons or stents. So far, stent manufacturers have not provided any information regarding side-branch expansion capacity of their stent platforms.
View Article and Find Full Text PDFSupplementary cementitious materials (SCM) can reduce the total amount of Portland cement clinker in concrete production. Rice husk ashes (RHA) can be converted from an agricultural by-product to a high-performance concrete constituent due to a high amount of reactive silica with pozzolanic properties if they are burnt under controlled conditions. The way and duration of combustion, the cooling process as well as the temperature have an effect on the silica form and thus, the chemical and physical performance of the RHA.
View Article and Find Full Text PDFBackground: Percutaneous coronary intervention is among the most common therapeutic interventions in cardiology. This procedure may, however, be associated with a rare, though life-threatening complication: acute coronary perforation (CP). CP is primarily treated using covered stents, which are made of bare metal stents with a polytetrafluoroethylene (PTFE) or polyurethane coating.
View Article and Find Full Text PDFThe interaction of different charged polymers, namely anionic polycarboxylate superplasticizer (PCE) and neutral polyethylene glycol (PEG) with potassium ions, and their effect on the yield stress of highly concentrated glass bead suspension (GBS), were studied under different concentrations of potassium ions ([K]). It was found that, compared to the neutral PEG, the negatively charged PCE can be adsorbed on glass beads (GB), and then decreases the yield stress of GBS. The increasing concentration of free polymer in the interstitial liquid phase with the increased polymer dosage leads to the higher yield stress of GBS, which may be caused by the higher depletion force.
View Article and Find Full Text PDFWe revisit the problem of how energy transfer through the turbulent cascade operates in compressible hydrodynamic turbulence. In general, there is no conservative compressible cascade since the kinetic and internal energy reservoirs can exchange energy through pressure dilatation. Moreover, statistically stationary turbulence at high Mach number can only be maintained in nearly isothermal gas, i.
View Article and Find Full Text PDFTo evaluate a MicroNet-covered stent designed for the carotid artery with the new ability to adjust to different vessel diameters. Thirty consecutive patients (mean age 72.1±7.
View Article and Find Full Text PDFResorbable magnesium scaffolds are used for the treatment of atherosclerotic coronary vascular disease and furthermore, for vascular restoration therapy. Recently, the first-in-man clinical studies with Magmaris showed promising results regarding the target lesion failure as well as vasomotion properties after 12 and 24 month. The consistency of in vivo degraded magnesium alloys in a cardiovascular environment is qualitatively described in literature, but only little has been disclosed about the actual change in mechanical properties and the behavior of the magnesium alloy degradation products.
View Article and Find Full Text PDFTo prevent implant failure due to fibrosis is a major objective in glaucoma research. The present study investigated the antifibrotic effects of paclitaxel (PTX), caffeic acid phenethyl ester (CAPE), and pirfenidone (PFD) coated microstent test specimens in a rat model. Test specimens based on a biodegradable blend of poly(4-hydroxybutyrate) biopolymer and atactic poly(3-hydroxybutyrate) (at.
View Article and Find Full Text PDFBackground: Drug-eluting stents (DES) compared to bare metal stents (BMS) have shown superior clinical performance, but are considered less suitable in complex cases. Most studies do not distinguish between DES and BMS with respect to their mechanical performance. The objective was to obtain mechanical parameters for direct comparison of BMS and DES.
View Article and Find Full Text PDFWithin this paper we analyzed the technical feasibility of a novel microstent for glaucoma therapy. For lowering of intraocular pressure, the flexible polyurethane (PUR) implant is designed to drain aqueous humour from the anterior chamber of the eye into subconjunctival, or alternatively suprachoroidal, space. The microstent includes a biodegradable, flow resisting polymer membrane serving as temporary flow resistance for the prevention of early postoperative hypotony.
View Article and Find Full Text PDFLarge-eddy simulations (LES) are a powerful tool in understanding processes that are inaccessible by direct simulations due to their complexity, for example, in the highly turbulent regime. However, their accuracy and success depends on a proper subgrid-scale (SGS) model that accounts for the unresolved scales in the simulation. We evaluate the applicability of two traditional SGS models, namely the eddy-viscosity (EV) and the scale-similarity (SS) models, and one recently proposed nonlinear (NL) SGS model in the realm of compressible magnetohydrodynamic (MHD) turbulence.
View Article and Find Full Text PDFEmbolic protection devices were developed to reduce the risk of stroke during carotid artery stenting. The aim of this study was to test the capture efficiency of five embolic protection devices under reproducible in vitro conditions. The setup consisted of silicone tubes representing the vessel modeling round and oval cross sections.
View Article and Find Full Text PDFPurpose: To report early clinical outcomes with a novel double-layer stent for the internal carotid artery (ICA) and the in vitro investigation of the stent's mechanical properties.
Methods: A prospective single-center study enrolled 30 consecutive patients (mean age 73.1±6.
Background/purpose: Biodegradable polymers are the main materials for coronary scaffolds. Magnesium has been investigated as a potential alternative and was successfully tested in human clinical trials. However, it is still challenging to achieve mechanical parameters comparative to permanent bare metal (BMS) and drug-eluting stents (DES).
View Article and Find Full Text PDFPurpose: To evaluate the in vitro mechanical and clinical implant behavior of a next-generation double-layer stent designed for the carotid artery.
Methods: The new double-layer CASPER-RX stent was implanted in 12 patients (median age 69 years; 8 men) with high-grade symptomatic internal carotid artery stenoses (mean 82%). In the in vitro experiments, the CASPER-RX stent (8-×40-mm model) was investigated with respect to its radial force on expansion and the bending stiffness of the stent system and of the stent in its expanded state, as well as the collapse pressure in a thin, flexible sleeve.
Purpose: A novel glaucoma drainage device (GDD) with local drug delivery (LDD) system was created and characterized for safety and effectiveness after implantation into the suprachoroidal space (SCS) of rabbit eyes.
Methods: Thin films of two different polymers, Poly(3-hydroxybutyrate) (P(3HB)) and Poly(4-hydroxybutyrate) (P(4HB)), containing the drugs mitomycin C (MitC) or paclitaxel (PTX) were attached to silicone-tubes to create LDD devices. The release kinetics of these drugs were explored in vitro using high performance liquid chromatography (HPLC).
Drug-coated balloons (DCB), which have emerged as a therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficacy and safety within a number of clinical studies. In vitro studies elucidating the correlation between coating additive and DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this regard, we examined three different DCB-systems, which were developed in former studies based on the ionic liquid cetylpyridinium salicylate, the body-own hydrogel hyaluronic acid and the pharmaceutically well-established hydrogel polyvinylpyrrolidone, considering coating morphology, coating thickness, drug-loss, drug-transfer to the vessel wall, residual drug-concentration on the balloon surface and entire drug-load during simulated use in an in vitro vessel model.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
November 2013
Intracoronary stents have markedly improved the outcomes of catheter-based coronary interventions. Intracoronary stent implantation rates of over 90% during coronary angioplasty are common. Stent implantations are associated with a small but statistically significant number of adverse outcomes including restenosis, thrombosis, strut malapposition, incomplete strut endothelialization, and various types of stenting failure.
View Article and Find Full Text PDFGlaucoma is a common cause of blindness in industrialized countries and is the most frequent cause of irreversible blindness worldwide. Since raised intraocular pressure (IOP) has been implicated as the major risk factor, the main goal of all glaucoma treatment is to reduce IOP sufficiently to prevent continuous irreversible retinal ganglion cell damage and progression of visual field loss. Pharmacological reduction of IOP is first-line therapy, followed by laser treatment of the trabecular meshwork and filtering glaucoma surgery, and cyclophotocoagulation of the ciliary body or allogenic implants.
View Article and Find Full Text PDF