The most characteristic feature of the human electroencephalogram is the peak alpha frequency (PAF). While PAF has been proposed as a biomarker in several diseases and disorders, the disease mechanisms modulating PAF, as well as its physiological substrates, remain elusive. This has partly been due to challenges related to experimental manipulation and invasive procedures in human neuroscience, as well as the scarcity of animal models where PAF is consistently present in resting-state.

View Article and Find Full Text PDF

Micro-electrocorticography (µECoG) electrodes have emerged to balance the trade-off between invasiveness and signal quality in brain recordings. However, its large-scale applicability is still hindered by a lack of comparative studies assessing the relationship between ECoG and traditional recording methods such as penetrating electrodes. This study aimed to compare somatosensory evoked potentials (SEPs) through the lenses of a µECoG and an intracortical microelectrode array (MEA).

View Article and Find Full Text PDF
Article Synopsis
  • This study examined how nerve injuries affect brain activity, specifically looking at hyperexcitability in the primary somatosensory cortex (S1) using a pig model.
  • Researchers recorded neuron activity with a multielectrode array to see how stimulating injured versus uninjured nerves changed brain responses.
  • The findings indicated that following nerve injury, there was a significant increase in excitability, particularly in cortical layer III, highlighting its key role in brain activity changes post-injury.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to create a long-term pain model using long-term potentiation in pigs to better understand pain mechanisms.
  • Researchers recorded brain activity in pigs before, during, and after stimulating the ulnar nerve with high-frequency stimulation (HFS) while also measuring their sensitivity to pain.
  • Results showed that mechanical sensitivity increased significantly after HFS and correlated with changes in brain activity, suggesting that the pig model closely mimics human pain conditions.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to track the development of ischemic stroke in pigs using intracortical recordings for high-resolution feedback on neural function, which could help in optimizing drug treatments.
  • Micro-electrode arrays were implanted into the pigs’ brains, and ischemic stroke was induced through a specific chemical injection, with neural responses measured continuously over time.
  • Results showed a significant decrease in cortical excitability after stroke, and the findings suggest that this pig model can bridge the gap between rodent studies and human applications for developing neuroprotective therapies.
View Article and Find Full Text PDF

Phantom limb pain (PLP) following amputation considerably reduces the quality of life, given a difficult to treat pain of highly variate profile. The loss of sensory input induces a complex pattern of neuroplastic changes of the sensory neural pathways and their central projections. Referred sensation areas (RSAs) may occur on the stump as a consequence of amputation, providing a direct path towards the altered central sensory projections.

View Article and Find Full Text PDF

The knowledge of the morphology and morphometry of peripheral nerves is essential for developing neural interfaces and understanding nerve regeneration in basic and applied research. Currently, the most adopted animal model is the rat, even though recent studies have suggested that the neuroanatomy of large animal models is more comparable to humans. The present knowledge of the morphological structure of large animal models is limited; therefore, the present study aims to describe the morphological characteristics of the Ulnar Nerve (UN) in pigs.

View Article and Find Full Text PDF

Modulation in the temporal pattern of transcutaneous electrical nerve stimulation (TENS), such as Pulse width modulated (PWM), has been considered a new dimension in pain and neurorehabilitation therapy. Recently, the potentials of PWM TENS have been studied on sensory profiles and corticospinal activity. However, the underlying mechanism of PWM TENS on cortical network which might lead to pain alleviation is not yet investigated.

View Article and Find Full Text PDF

Background: A pressure algometer is a valuable tool for assessing the mechanical nociceptive threshold (MNT) in clinical pain studies. Recent research has turned to large animal models of pain because of the closer anatomy and physiology to humans. Although the reliability and usefulness of the MNT have been extensively validated in humans, similar data from large animals is still sparse.

View Article and Find Full Text PDF

Over the last decades, conventional transcutaneous electrical nerve stimulation (TENS) has been utilized as an efficient rehabilitation intervention for alleviation of chronic pain, including phantom limb pain (PLP). However, recently the literature has increasingly focused on alternative temporal stimulation patterns such as pulse width modulation (PWM). While the effect of non-modulated high frequency (NMHF) TENS on somatosensory (SI) cortex activity and sensory perception has been studied, the possible alteration following PWM TENS at the SI has not yet been explored.

View Article and Find Full Text PDF

Extracting information from the peripheral nervous system with implantable devices remains a significant challenge that limits the advancement of closed-loop neural prostheses. Linear electrode arrays can record neural signals with both temporal and spatial selectivity, and velocity selective recording using the delay-and-add algorithm can enable classification based on fibre type. The maximum likelihood estimation method also measures velocity and is frequently used in electromyography but has never been applied to electroneurography.

View Article and Find Full Text PDF

Transcutaneous electrical nerve stimulation (TENS) has been suggested as a possible non-invasive pain treatment. However, the underlying mechanism of the analgesic effect of TENS and how brain network functional connectivity (FC) is affected following the use of TENS is not yet fully understood. The purpose of this study was to investigate the effect of high-frequency TENS on the alteration of functional brain network connectivity and the corresponding topographical changes, besides perceived sensations.

View Article and Find Full Text PDF

Conventional transcutaneous electrical nerve stimulation (TENS) has been reported to effectively alleviate chronic pain, including phantom limb pain (PLP). Recently, literature has focused on modulated TENS patterns, such as pulse width modulation (PWM) and burst modulation (BM), as alternatives to conventional, non-modulated (NM) sensory neurostimulation to increase the efficiency of rehabilitation. However, there is still limited knowledge of how these modulated TENS patterns affect corticospinal (CS) and motor cortex activity.

View Article and Find Full Text PDF

Decoding information from the peripheral nervous system via implantable neural interfaces remains a significant challenge, considerably limiting the advancement of neuromodulation and neuroprosthetic devices. The velocity selective recording (VSR) technique has been proposed to improve the classification of neural traffic by combining temporal and spatial information through a multi-electrode cuff (MEC). Therefore, this study investigates the feasibility of using the VSR technique to characterise fibre type based on the electrically evoked compound action potentials (eCAP) propagating along the ulnar nerve of pigs in vivo.

View Article and Find Full Text PDF

Translating basic pain research from rodents to humans has proven to be a challenging task. Efforts have been made to develop preclinical large animal models of pain, such as the pig. However, no consistent overview and comparison of pig models of pain are currently available.

View Article and Find Full Text PDF

This study implements the use of Danish Landrace pigs as subjects for the long-term potentiation (LTP)-like pain model. This is accomplished by analyzing changes in the primary somatosensory cortex (S1) in response to electrical stimulation on the ulnar nerve after applying high-frequency electrical stimulation (HFS) on the ulnar nerve. In this study, eight Danish Landrace pigs were electrically stimulated, through the ulnar nerve, to record the cortically evoked response in S1 by a 16-channel microelectrode array (MEA).

View Article and Find Full Text PDF

. Despite decades of research on central processing of pain, there are still several unanswered questions, in particular regarding the brain regions that may contribute to this alerting sensation. Since it is generally accepted that more than one cortical area is responsible for pain processing, there is an increasing focus on the interaction between areas known to be involved.

View Article and Find Full Text PDF

Aim: Limb loss is a dramatic event with a devastating impact on a person's quality of life. Prostheses have been used to restore lost motor abilities and cosmetic appearance. Closing the loop between the prosthesis and the amputee by providing somatosensory feedback to the user might improve the performance, confidence of the amputee, and embodiment of the prosthesis.

View Article and Find Full Text PDF

Transcutaneous electrical nerve stimulation (TENS) has been reported to alleviate pain in chronic pain patients. Currently, there is limited knowledge how TENS affects can cause cortical neuromodulation and lead to modulation of non-painful and painful sensations. Our aim was therefore to investigate the effect of conventional, high-frequency TENS on cortical activation and perceived sensations in healthy subjects.

View Article and Find Full Text PDF

A better understanding of neural pain processing and of the development of pain over time, is critical to identify objective measures of pain and to evaluate the effect of pain alleviation therapies. One issue is, that the brain areas known to be related to pain processing are not exclusively responding to painful stimuli, and the neuronal activity is also influenced by other brain areas. Functional connectivity reflects synchrony or covariation of activation between groups of neurons.

View Article and Find Full Text PDF

Background: The current knowledge on the role of SI and ACC in acute pain processing and how these contribute to the development of chronic pain is limited. Our objective was to investigate differences in and modulation of intracortical responses from SI and ACC in response to different intensities of peripheral presumed noxious and non-noxious stimuli in the acute time frame of a peripheral nerve injury in rats.

Methods: We applied non-noxious and noxious electrical stimulation pulses through a cuff electrode placed around the sciatic nerve and measured the cortical responses (six electrodes in each cortical area) before and after the spared nerve injury model.

View Article and Find Full Text PDF

Phantom limb pain (PLP) is pain felt in the missing limb in amputees. Somatosensory input delivered as high-frequency surface electrical stimulation may provoke a significant temporary decrease in PLP. Also, transcutaneous electrical nerve stimulation (TENS) is a somatosensory input that may activate descending inhibitory systems and thereby relieve pain.

View Article and Find Full Text PDF

Following amputation, almost two-thirds of amputees experience unpleasant to painful sensations in the area of the missing limb. Whereas the mechanism of phantom limb pain (PLP) remains unknown, it has been shown that maladaptive cortical plasticity plays a major role in PLP. Transcutaneous electrical nerve stimulation (TENS) generating sensory input is believed to be beneficial for PLP relief.

View Article and Find Full Text PDF

Various mechanisms in generating phantom limb pain (PLP) have been hypothesized in the literature. However, there still is no clear understanding of how PLP develops and why it presents. Amputation leads to permanent anatomical and physiological changes of the neural path previously supplying the brain with sensory input, as well as to formation of referred sensation areas (RSAs) on the stump or its vicinity.

View Article and Find Full Text PDF

Today there are multiple implantable medical devices on the market. The type of implants that interface the body's tissues has been considered to have particular strong ethical implications. This article describes a development of a novel practice for ethical assessment and reflection within medical device research and development of non-CE marked medical devices, taking the perspective of both the ethicist and the researcher.

View Article and Find Full Text PDF