Purpose: The management of soft tissue sarcoma (STS) at reference centers with specialized multidisciplinary tumor boards (MTB) improves patient survival. The German Cancer Society (DKG) certifies sarcoma centers in German-speaking countries, promoting high standards of care. This study investigated the variability in treatment recommendations for localized STS across different German-speaking tertiary sarcoma centers.
View Article and Find Full Text PDFImaging is used for lymphoma detection, Ann Arbor/Lugano staging, and treatment response assessment. [F]FDG PET/CT should be used for most lymphomas, including Hodgkin lymphoma, aggressive/high-grade Non-Hodgkin lymphomas (NHL) such as diffuse large B-cell lymphoma, and many indolent/low-grade NHLs such as follicular lymphoma. Apart from these routinely FDG-avid lymphomas, some indolent NHLs, such as marginal zone lymphoma, are variably FDG-avid; here, [F]FDG PET/CT is an alternative to contrast-enhanced CT at baseline and may be used for treatment response assessment if the lymphoma was FDG-avid at baseline.
View Article and Find Full Text PDFPurpose: This study evaluates the diagnostic performance of artificial intelligence (AI)-based coronary computed tomography angiography (CCTA) for detecting coronary artery disease (CAD) and assessing fractional flow reserve (FFR) in asymptomatic male marathon runners.
Material And Methods: We prospectively recruited 100 asymptomatic male marathon runners over the age of 45 for CAD screening. CCTA was analyzed using AI models (CorEx and Spimed-AI) on a local server.
A 64-year-old woman with meningioma presented with left-sided lenticulostriatal ischemia following craniotomy and debulking of a sphenoid wing meningioma. For subsequent radiotherapy planning, an SSTR-targeted PET/CT using the novel ligand 18 F-SiTATE was performed 2.5 months thereafter.
View Article and Find Full Text PDFPurpose: To assess the eligibility of patients with advanced or recurrent solid malignancies presented to a molecular tumor board (MTB) at a large precision oncology center for inclusion in trials with the endpoints objective response rate (ORR) or duration of response (DOR) based on Response Evaluation Criteria in Solid Tumors (RECIST version 1.1).
Methods: Prospective patients with available imaging at the time of presentation in the MTB were included.
: Cervical collars (CC) are routinely used in prehospital trauma treatment. However, over the past years, their application was discussed more critically since they increase intravenous pressure due to reduced venous drainage and the possibility of secondary cervical spine injury. Guidelines have been adjusted accordingly.
View Article and Find Full Text PDFBackground: This study explores the predictive and monitoring capabilities of clinical and multiparametric MR parameters in assessing capecitabine and temozolomide (CAPTEM) therapy response in patients with neuroendocrine tumors (NET).
Patients And Methods: This retrospective study (n = 44) assessed CAPTEM therapy response in neuroendocrine liver metastases (NELM) patients. Among 33 monitored patients, as a subgroup of the overall study cohort, pretherapeutic and follow-up MRI data (size, apparent diffusion coefficient [ADC] values, and signal intensities), along with clinical parameters (chromogranin A [CgA] and Ki-67%), were analyzed.
This study investigated the efficacy of single-phase dual-energy CT (DECT) in differentiating pulmonary hamartomas from malignant lung lesions using virtual non-contrast (VNC), iodine, and fat quantification. Forty-six patients with 47 pulmonary lesions (mean age: 65.2 ± 12.
View Article and Find Full Text PDFPurpose: The purpose of this study was to evaluate the capabilities of photon-counting (PC) CT combined with artificial intelligence-derived coronary computed tomography angiography (PC-CCTA) stenosis quantification and fractional flow reserve prediction (FFRai) for the assessment of coronary artery disease (CAD) in transcatheter aortic valve replacement (TAVR) work-up.
Materials And Methods: Consecutive patients with severe symptomatic aortic valve stenosis referred for pre-TAVR work-up between October 2021 and June 2023 were included in this retrospective tertiary single-center study. All patients underwent both PC-CCTA and ICA within three months for reference standard diagnosis.
Purpose: The emergence of chimeric antigen receptor (CAR) T-cell therapy fundamentally changed the management of individuals with relapsed and refractory large B-cell lymphoma (LBCL). However, real-world data have shown divergent outcomes for the approved products. The present study therefore set out to evaluate potential risk factors in a larger cohort.
View Article and Find Full Text PDFTech Vasc Interv Radiol
September 2023
Magnetic resonance (MR) image guidance has demonstrated significant potential in the field of interventional radiology in several applications. This article covers the main points of MR-guided hepatic tumor ablation as a representative of MR-guided procedures. Patient selection and appropriate equipment utilization are essential for successful MR-guided tumor ablation.
View Article and Find Full Text PDFBackground: This study aimed to evaluate the predictive and monitoring role of somatostatin receptor (SSTR) positron emission tomography-computed tomography (PET/CT) and clinical parameters in patients with neuroendocrine liver metastases (NELM) from pancreatic neuroendocrine tumors (pNET) receiving capecitabine and temozolomide (CAPTEM).
Patients And Methods: This retrospective study included twenty-two patients with pNET and NELM receiving CAPTEM who underwent pre- and post-therapeutic Ga-DOTATATE/-TOC PET/CT. Imaging (including standardized uptake value [SUV] of target lesions [NELM and pNET], normal spleen and liver) and clinical (Chromogranin A [CgA], Ki-67) parameters were assessed.
Background: Treatment of hematological malignancies with chimeric antigen receptor modified T cells (CART) is highly efficient, but often limited by an immune effector cell-associated neurotoxicity syndrome (ICANS). As conventional MRI is often unremarkable during ICANS, we aimed to examine whether resting-state functional MRI (rsfMRI) is suitable to depict and quantify brain network alterations underlying ICANS in the individual patient.
Methods: The dysconnectivity index (DCI) based on rsfMRI was longitudinally assessed in systemic lymphoma patients and 1 melanoma patient during ICANS and before or after clinical resolution of ICANS.
Background: Chimeric antigen receptor T-cell therapy (CART) is effective for patients with refractory or relapsed lymphoma with prolongation of survival. We aimed to improve the prediction of Lugano criteria for overall survival (OS) at 30-day follow-up (FU1) by including the pre-infusion tumor growth rate (TGR) and its early change to 30-day FU1 imaging (TGR).
Methods: Consecutive patients with pre-baseline (pre-BL), baseline (BL) and FU1 imaging with CT or positron emission tomography/CT before CART were included.
Chimeric antigen receptor T-cell therapy (CART) can be administered outpatient yet requires management of potential side effects such as cytokine release syndrome (CRS) and immune effector cell-associated neurotoxicity syndrome (ICANS). The pre-infusion tumor burden is associated with CRS, yet there is no data on the relevance of pre-infusion tumor growth rate (TGR). Our objective was to investigate TGR for the occurrence and severity of CRS and ICANS.
View Article and Find Full Text PDFBackground: Histopathology is the reference standard for diagnosing liver metastases of neuroendocrine tumors (NETs). Somatostatin receptor-positron emission tomography / computed tomography (SSR-PET/CT) has emerged as a promising non-invasive imaging modality for staging NETs. We aimed to assess the diagnostic accuracy of SSR-PET/CT in the identification of liver metastases in patients with proven NETs compared to histopathology.
View Article and Find Full Text PDFPurpose: The aim of this study was to compare the diagnostic performance of different sets of MR sequences in detecting extrahepatic disease of NETs on routine liver magnetic resonance imaging (MRI).
Method: One hundred twenty-seven patients with NETs with and without hepatic and extrahepatic metastases who underwent liver MRI and SSTR-PET/CT were retrospectively analyzed. Two radiologists evaluated in consensus in four sessions: (1) non-contrast T1w+T2w (NC), (2) NC+DWI, (3) NC+ contrast-enhanced T1w (CE), and (4) NC+DWI+CE the presence and number of metastases (lymph nodes, bone, peritoneal surface, lung base, and abdominal organ).
Objectives: As structured reporting is increasingly used in the evaluation of prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA-PET/CT) for prostate cancer, there is a need to assess the reliability of these frameworks. This study aimed to evaluate the intra- and interreader agreement among readers with varying levels of experience using PSMA-RADS 1.0 for interpreting PSMA-PET/CT scans, even when blinded to clinical data, and therefore to determine the feasibility of implementing this reporting system in clinical practice.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
August 2023
Organosiloxanes are industrially produced worldwide in millions of tons per annum and are widely used by industry, professionals, and consumers. Some of these compounds are PBT (persistent, biaccumulative and toxic) or vPvB (very persistent and very bioaccumulative). If organosiloxanes react at all in the environment, Si-O bonds are hydrolyzed or Si-C bonds are oxidatively cleaved, to result finally in silica and carbon dioxide.
View Article and Find Full Text PDFPurpose: To identify prognostic clinical and imaging parameters for patients with neuroendocrine liver metastases (NELMs) undergoing transarterial radioembolization (TARE).
Materials And Methods: Forty-seven patients (27 men; mean age, 64 years) with NELMs who received TARE, along with pre-procedure liver MRI and Ga-DOTATATE positron emission tomography/computed tomography were included. Apparent diffusion coefficient and standardized uptake value (SUV) of three liver metastases, normal spleen and liver were measured.