This study presents a novel approach for monitoring waste substrate digestion under high-density polyethylene (HDPE) geomembranes in sewage treatment plants. The method integrates infrared thermal imaging with a clustering algorithm to predict the distribution of various substrates beneath Traditional outdoor large-scale opaque geomembranes, using solar radiation as an excitation source. The technique leverages ambient weather conditions to assess the thermal responses of HDPE covers.
View Article and Find Full Text PDFThis paper reports on an acoustic emission (AE) sensor based on relaxor ferroelectric single crystal (RFSC) transduction. The sensor crystal is arranged into a Linear Array for Modal Decomposition and Analysis (LAMDA), with the sensor interrogated by a bespoke high-bandwidth instrument. The efficacy of RFSC LAMDA sensors is showcased through a series of comparative experiments, which include the simultaneous acquisition of pencil lead break (PLB) AEs in a 1.
View Article and Find Full Text PDFA simplified axisymmetric model of a transfemoral osseointegration implant was used to investigate the influence of the contact condition at the bone-implant interface on the vibrational response. The experimental setup allowed the degree of implant tightness to be controlled using a circumferential compression device affixed to the bone. Diametrically placed sensors allowed torsional modes to be distinguished from flexural modes.
View Article and Find Full Text PDFGlass fibre-reinforced polymer (GFRP) is a suitable substrate material for constructing a Conformal Load-Bearing Antenna Structure (CLAS). The relative permittivity of the CLAS substrate, which determines its resonant frequency, is affected by damage sustained by GFRP. This paper investigates the effects of damage (induced by mechanically loading the substrate) on the resonant response of the CLAS.
View Article and Find Full Text PDFThis paper presents an overview of integrating new research outcomes into the development of a structural health monitoring strategy for the floating cover at the Western Treatment Plant (WTP) in Melbourne, Australia. The size of this floating cover, which covers an area of approximately 470 m × 200 m, combined with the hazardous environment and its exposure to extreme weather conditions, only allows for monitoring techniques based on remote sensing. The floating cover is deformed by the accumulation of sewage matter beneath it.
View Article and Find Full Text PDFThis study aims to enhance diagnostic capabilities for optimising the performance of the anaerobic sewage treatment lagoon at Melbourne Water's Western Treatment Plant (WTP) through a novel machine learning (ML)-based monitoring strategy. This strategy employs ML to make accurate probabilistic predictions of biogas performance by leveraging diverse real-life operational and inspection sensor and other measurement data for asset management, decision making, and structural health monitoring (SHM). The paper commences with data analysis and preprocessing of complex irregular datasets to facilitate efficient learning in an artificial neural network.
View Article and Find Full Text PDFAcoustic emission (AE) testing and Lamb wave inspection techniques have been widely used in non-destructive testing and structural health monitoring. For thin plates, the AEs arising from structural defect development (e.g.
View Article and Find Full Text PDFStrain sensing technology using fibre Bragg grating (FBG) sensors is an attractive capability for aerospace structural health monitoring (SHM) and assessment because they offer resistance to harsh environments, low maintenance, and potential for high density and high strain sensing. The development of FBG inscription techniques through the fibre polymer coating using infrared (IR) lasers has overcome the mechanical weaknesses introduced by removal of the fibre coating, which is typically required for conventional UV laser inscription of FBGs. Type I and Type II femtosecond gratings are fabricated using through-coating inscription techniques, but the higher laser energy used for Type II gratings damages the glass fibre core, impacting mechanical performance.
View Article and Find Full Text PDFWhile acoustic emission (AE) testing can be used as a valuable technique in structural health monitoring and non-destructive testing, little research has been conducted to establish its sources, particularly in 2024-T3 aluminium alloys. The major contribution of this work is that it provides a method to obtain a better linear relationship of count rate with crack growth rate based on waveform. This paper aims to characterise AE sources by synchronising the AE waveforms with load levels and then to propose possible dominant frequency ranges.
View Article and Find Full Text PDFOsseointegration implant has attracted significant attention as an alternative treatment for transfemoral amputees. It has been shown to improve patients' sitting and walking comfort and control of the artificial limb, compared to the conventional socket device. However, the patients treated with osseointegration implants require a long rehabilitation period to establish sufficient femur-implant connection, allowing the full body weight on the prosthesis stem.
View Article and Find Full Text PDFOsseointegrated prostheses are widely used following transfemoral amputation. However, this technique requires sufficient implant stability before and during the rehabilitation period to mitigate the risk of implant breakage and loosening. Hence, reliable assessment methods for the osseointegration process are essential to ensure initial and long-term implant stability.
View Article and Find Full Text PDFReliable and quantitative assessments of bone quality and fracture healing prompt well-optimised patient healthcare management and earlier surgical intervention prior to complications of nonunion and malunion. This study presents a clinical investigation on modal frequencies associations with musculoskeletal components of human legs by using a prototype device based on a vibration analysis method. The findings indicated that the first out-of-plane and coupled modes in the frequency range from 60 to 110 Hz are associated with the femur length, suggesting these modes are suitable quantitative measures for bone evaluation.
View Article and Find Full Text PDFOne of the important functions of antennas is to facilitate wireless communication. The IEEE 802.11 is part of the IEEE802 set of local area network technical standards, and specifies the media access control and physical layer protocols for implementing wireless local area network computer communication.
View Article and Find Full Text PDFAlthough fibre Bragg gratings (FBGs) offer obvious potential for use in high-density, high-strain sensing applications, the adoption of this technology in the historically conservative aerospace industry has been slow. There are several contributing factors, one of which is variability in the reported performance of these sensors in harsh and fatigue prone environments. This paper reports on a comparative evaluation of the fatigue performance of FBG sensors written according to the same specifications using three different grating manufacturing processes: sensors written in stripped and re-coated fibres, sensors written during the fibre draw process and sensors written through fibre coating.
View Article and Find Full Text PDFThe lack of a quantitative method to adequately assess fractured bone healing that has undergone fixation limits prognostic capabilities on patients' optimal return to work. This paper addresses the use of vibrational analysis to monitor the state of healing of a plate-screw fixated femur and supplement the current clinical radiographic assessment. This experimental study involves an osteotomised composite femur specimen enclosed by modelling clay to simulate the damping effect of overlying soft tissues.
View Article and Find Full Text PDFQuantitative and reliable monitoring of osseointegration will help further evaluate the integrity of the orthopaedic construct to promote novel prosthesis design and allow early mobilisation. Quantitative assessment of the degree or the lack of osseointegration is important for the clinical management with the introduction of prosthetic implants to amputees. Acousto-ultrasonic wave propagation has been used in structural health monitoring as well as human health monitoring but so far has not extended to osseointegrated implants or prostheses.
View Article and Find Full Text PDFLeakage is undesirable in water distribution networks, as leaky pipes are financially costly both to water utilities and consumers. The ability to detect, locate, and quantify leaks can significantly improve the service delivered. Optical fibre sensors (OFS) have previously demonstrated their capabilities in performing real-time and continuous monitoring of pipe strength leak detection.
View Article and Find Full Text PDFFloating covers used in waste water treatment plants are one of the many structures formed with membrane materials. These structures are usually large and can spread over an area measuring 470 m × 170 m. The aim of this paper is to describe recent work to develop an innovative and effective approach for structural health monitoring (SHM) of such large membrane-like infrastructure.
View Article and Find Full Text PDFReliable and quantitative non-destructive evaluation for small fatigue cracks, in particular those in hard-to-inspect locations, is a challenging problem. Guided waves are advantageous for structural health monitoring due to their slow geometrical decay of amplitude with propagating distance, which is ideal for rapid wide-area inspection. This paper presents a 3D laser vibrometry experimental and finite element analysis of the interaction between an edge-guided wave and a small through-thickness hidden edge crack on a racecourse shaped hole that occurs, in practice, as a fuel vent hole.
View Article and Find Full Text PDFOver the past few decades, there has been a considerable interest in the use of distributed optical fibre sensors (DOFS) for structural health monitoring of composite structures. In aerospace-related work, health monitoring of the adhesive joints of composites has become more significant, as they can suffer from cracking and delamination, which can have a significant impact on the integrity of the joint. In this paper, a swept-wavelength interferometry (SWI) based DOFS technique is used to monitor the fatigue in a flush step lap joint composite structure.
View Article and Find Full Text PDFBackground: In thyroidectomy, little has been reported on the differential recurrent laryngeal nerve (RLN) palsy rates between the left and right sides. Even less is known about the potential differences causing these differential rates. This study reports the left versus right RLN palsy rates of total thyroidectomy cases in a single institution, relating them to the comparative stiffness of the left and right porcine RLNs.
View Article and Find Full Text PDFBackground: Randomized controlled trials (RCTs) are commonly used to inform clinical practice; however, it is unclear how generalizable RCT data are to patients in routine clinical practice. The authors of this report assessed the availability and applicability of randomized evidence guiding medical decisions in a cohort of patients who were evaluated for consideration of definitive management in a radiation oncology clinic.
Methods: The medical records of consecutive, new patient consultations between January and March 2007 were reviewed.
Sacral fractures from high-impact trauma often cause instability in the pelvic ring structure. Treatment is by internal fixation which clamps the fractured edges together to promote healing. Healing could take up to 12 weeks whereby patients are bedridden to avoid hindrances to the fracture from movement or weight bearing activities.
View Article and Find Full Text PDFPurpose: To assess the prognostic implications of mediastinal positron emission tomographic (PET) findings in patients undergoing curative resection of non-small cell lung cancer (NSCLC) who have histologically negative mediastinal lymph nodes (LNs), with the hypothesis that positive findings at PET are prognostic even in patients with negative histologic findings in the LNs.
Materials And Methods: Records of patients with a preoperative PET undergoing curative surgery, without adjuvant radiation, for pathologic T1-3N0-1 NSCLC at the University of North Carolina between 2000 and 2006 were reviewed as an institutional review board-approved HIPAA-compliant retrospective study. Ninety patients were evaluable (all histologically negative in mediastinum; 44 with both mediastinoscopy and surgery); 13 patients had positive mediastinal PET findings, and 77 had negative mediastinal PET findings.