Clin Optom (Auckl)
January 2019
Purpose: The purpose of this evaluation was to compare the experience of habitual contact lens wearers with that of nonwearers when fitted with a novel toric nesofilcon A contact lens (Biotrue ONEday for Astigmatism lens; Bausch & Lomb Incorporated, Rochester, NY, USA), for wearer comfort, vision, and satisfaction in a real-world setting.
Materials And Methods: Participating eye care practitioners (ECPs) prescribed toric nesofilcon A lenses to their astigmatic patients as part of their routine clinical practices. Accordingly, 1,253 patients successfully completed the evaluation; of these, 51% wore contact lenses habitually, 41% wore eyeglasses, and 8% had no prior vision correction.
Purpose: This study was conducted to determine 1) the concentration of hyaluronan (HA) in the tear films of contact lens (CL) wearers versus non-CL wearers and 2) whether HA sorbed from Biotrue, an HA-containing multipurpose solution (MPS), onto senofilcon A lenses affects the concentration of HA in tears after 2 hours of wear.
Patients And Methods: Tears of habitual CL wearers and non-CL wearers were collected on Schirmer strips at baseline and after 2 hours of wear of senofilcon A CLs that had first been either rinsed with Sensitive Eyes Saline or soaked in Biotrue MPS for 14 hours. HA concentrations were measured by enzyme-linked immunosorbent assay (ELISA) and adjusted for sample volumes.
Purpose: An increased risk of corneal infiltrative events has been noted with the use of certain contact lenses and multipurpose solutions (MPS). This study was designed to evaluate tear cytokine assay as a sensitive, objective, and quantitative measure of the ocular surface response to contact lens/MPS and to consider the assay's clinical relevance in the context of other measures of ocular surface response.
Methods: Two MPS, ReNu® Fresh™ (RNF) and Opti-Free® RepleniSH (OFR), were used with daily wear silicone hydrogel contact lenses in a randomized, prospective crossover study involving 26 subjects.
Purpose: The purpose of this study was to measure upper and lower tear menisci on contact lenses using real time optical coherence tomography (OCT).
Methods: Both eyes of 20 adapted contact lens wearers were imaged when they wore two types of silicone hydrogel lenses, balafilcon A on one eye and galyfilcon A on the other eye. The height, radius, and area of upper and lower tear menisci were obtained before, immediately after, and 20 minutes after lens wear on two consecutive days.