Publications by authors named "William M Whelan"

The magnetic field (MF) induced alignment of cellulose nanocrystals (CNC) within a starch matrix is investigated and its effect on the physicochemical and mechanical properties of the nanocomposites are discussed in the paper. Two different kinds of CNC i.e.

View Article and Find Full Text PDF

Radiance spectroscopy was applied to the interstitial detection of localized inclusions containing Au nanocages or nanorods with various concentrations embedded in porcine muscle phantoms. The radiance was quantified using a perturbation approach, which enabled the separation of contributions from the porcine phantom and the localized inclusion, with the inclusion serving as a perturbation probe of photon distributions in the turbid medium. Positioning the inclusion at various places in the phantom allowed for tracking of photons that originated from a light source, passed through the inclusion's location, and reached a detector.

View Article and Find Full Text PDF

Optoacoustic (OA) imaging was employed to distinguish normal from neoplastic tissues in a transgenic murine model of prostate cancer. OA images of five tumor-bearing mice and five age-matched controls across a 14 mm × 14 mm region of interest (ROI) on the lower abdomen were acquired using a reverse-mode OA imaging system (Seno Medical Instruments Inc., San Antonio, Texas).

View Article and Find Full Text PDF

The canine prostate is a close match for the human prostate and is used in research of prostate cancers. Determining accurately optical absorption and scattering properties of the gland in a wide spectral range (preferably in a minimally invasive way), linking optical properties to concentrations of major endogenous chromophores, and detecting the presence of localized optical inhomogeneities like inclusions of gold nanoparticles for therapeutic and diagnostic purposes, are among the major challenges for researchers. The goal of the article is to demonstrate a feasibility of the multifunctional radiance spectroscopy platform in providing the required information.

View Article and Find Full Text PDF

We demonstrated the application of relative radiance-based continuous wave (cw) measurements for recovering absorption and scattering properties (the effective attenuation coefficient, the diffusion coefficient, the absorption coefficient and the reduced scattering coefficient) of bulk porcine muscle phantoms in the 650-900 nm spectral range. Both the side-firing fiber (the detector) and the fiber with a spherical diffuser at the end (the source) were inserted interstitially at predetermined locations in the phantom. The porcine phantoms were prostate-shaped with ∼4 cm in diameter and ∼3 cm thickness and made from porcine loin or tenderloin muscles.

View Article and Find Full Text PDF

We analyze a role of a localized inclusion as a probe for spatial distributions of migrating photons in turbid media. We present new experimental data and two-dimensional analysis of radiance detection of a localized absorptive inclusion formed by gold nanoparticles in Intralipid-1% when the target is translated along the line connecting the light source and detector. Data are analyzed using the novel analytical expression for the relative angular photon distribution function for radiance developed by extending the perturbation approach for fluence.

View Article and Find Full Text PDF

Gold nanoparticles can be used as molecular contrast agents binding specifically to cancer sites and thus delineating tumor regions. Imaging gold nanoparticles deeply embedded in tissues with optical techniques possesses significant challenges due to multiple scattering of optical photons that blur the obtained images. Both diagnostic and therapeutic applications can benefit from a minimally invasive technique that can identify, localize, and quantify the payloads of gold nanoparticles deeply embedded in biological tissues.

View Article and Find Full Text PDF

Detection of non-scattering domains (voids) is an area of active research in biomedical optics. To avoid complexities of image reconstruction algorithms and requirements of a priori knowledge of void locations inherent to diffuse optical tomography (DOT), it would be useful to establish specific experimental signatures of voids that would help identify and detect them by other means. To address this, we present a radiance-based spectro-angular mapping approach that identifies void locations in the angular domain and establishes their spectral features.

View Article and Find Full Text PDF

We present a new method for extracting the effective attenuation coefficient and the diffusion coefficient from relative spectrally resolved cw radiance measurements using the diffusion approximation. The method is validated on both simulated and experimental radiance data sets using Intralipid-1% as a test platform. The effective attenuation coefficient is determined from a simple algebraic expression constructed from a ratio of two radiance measurements at two different source-detector separations and the same 90° angle.

View Article and Find Full Text PDF

We present a new approach to the analysis of radiance in turbid media. The approach combines data from spectral, angular and spatial domains in a form of spectro-angular maps. Mapping provides a unique way to visualize details of light distribution in turbid media and allows tracking changes with distance.

View Article and Find Full Text PDF

Interstitial fiber-optic-based approaches used in both diagnostic and therapeutic applications rely on localized light-tissue interactions. We present an optical technique to identify spectrally and spatially specific exogenous chromophores in highly scattering turbid media. Point radiance spectroscopy is based on directional light collection at a single point with a side-firing fiber that can be rotated up to 360 deg.

View Article and Find Full Text PDF

Raman spectroscopy is used to study the effects of heating on specific molecular bonds present in albumen-based coagulation phantoms and ex-vivo tissues. Thermal coagulation is induced by submerging albumen-based phantoms in a 75°C water bath to achieve target temperatures of 45, 55, 65, and 75°C. Laser photocoagulation is performed on ex-vivo bovine muscle samples, yielding induced temperatures between 46 and 90°C, as reported by implanted microthermocouples.

View Article and Find Full Text PDF

Several studies have explored the potential of optoacoustic imaging for monitoring thermal therapies, yet the origin of the contrast in the images is not well understood. A technique is required to measure the changes in the optical and thermomechanical properties of tissues upon coagulation to better understand this contrast. An interferometric method is presented for measuring simultaneously the optical and thermomechanical properties of native and coagulated ex-vivo bovine tissue samples based on analysis of the surface displacement of irradiated samples.

View Article and Find Full Text PDF

Photoacoustic (more precisely, photothermoacoustic) signals generated by the absorption of photons can be related to the incident laser fluence rate. The dependence of frequency domain photoacoustic (FD-PA) signals on the optical absorption coefficient (micro(a)) and the effective attenuation coefficient (micro(eff)) of a turbid medium [polyvinyl chloride-plastisol (PVCP)] with tissuelike optical properties was measured, and empirical relationships between these optical properties and the photoacoustic (PA) signal amplitude and the laser fluence rate were derived for the water (PVCP system with and without optical scatterers). The measured relationships between these sample optical properties and the PA signal amplitude were found to be linear, consistent with FD-PA theory: micro(a)=a(A/Phi)-b and micro(eff)=c(A/Phi)+d, where Phi is the laser fluence, A is the FD-PA amplitude, and a, .

View Article and Find Full Text PDF

Interstitial quantification of the optical properties of tissue is important in biomedicine for both treatment planning of minimally invasive laser therapies and optical spectroscopic characterization of tissues, for example, prostate cancer. In a previous study, we analyzed a method first demonstrated by Dickey et al., [Phys.

View Article and Find Full Text PDF

In an effort to understand dynamic optical changes during laser interstitial thermal therapy (LITT), we utilize the perturbative solution of the diffusion equation in heterogeneous media to formulate scattering weight functions for cylindrical line sources. The analysis explicitly shows how changes in detected interstitial light intensity are associated with the extent and location of the volume of thermal coagulation during treatment. Explanations for previously reported increases in optical intensity observed early during laser heating are clarified using the model and demonstrated with experimental measurements in ex vivo bovine liver tissue.

View Article and Find Full Text PDF

Frequency-domain correlation and spectral analysis photothermoacoustic (FD-PTA) imaging is a promising new technique, which is being developed to detect tumor masses in turbid biological tissue. Unlike conventional biomedical photoacoustics which uses time-of-flight acoustic information induced by a pulsed laser to indicate the tumor size and location, in this research, a new FD-PTA instrument featuring frequency sweep (chirp) and heterodyne modulation and lock-in detection of a continuous-wave laser source at wavelength is constructed and tested for its depth profilometric capabilities with regard to turbid media imaging. Owing to the linear relationship between the depth of acoustic signal generation and the delay time of signal arrival to the transducer, information specific to a particular depth can be associated with a particular frequency in the chirp signal.

View Article and Find Full Text PDF

A novel optoacoustic phantom made of polyvinyl chloride-plastisol (PVCP) for optoacoustic studies is described. The optical and acoustic properties of PVCP were measured. Titanium dioxide (TiO2) powder and black plastic colour (BPC) were used to introduce scattering and absorption, respectively, in the phantoms.

View Article and Find Full Text PDF

Background And Objectives: Fluoroptic sensors are used to measure interstitial temperatures but their utility for monitoring laser interstitial thermal therapy (LITT) is unclear because these sensors exhibit a measurement artefact when exposed to the near-infrared (NIR) treatment light. This study investigates the cause of the artefact to determine whether fluoroptic sensors can provide reliable temperature measurements during LITT.

Study Design/materials And Methods: The temperature rise measured by a fluoroptic sensor irradiated in non-absorbing media (air and water) was considered an artefact.

View Article and Find Full Text PDF

Optical monitoring relates the dynamic changes in measured light intensity to the extent of treatment-induced coagulation that occurs during laser interstitial thermal therapy. We utilized a two-region Monte Carlo simulation to elucidate the nature of the changes in interstitial radiance and fluence that result from the formation of a volume of thermal coagulation surrounding a cylindrical emitter. Using simulation results, we demonstrate that radiance sensors are more sensitive than traditional fluence sensors to coagulation-induced scattering changes.

View Article and Find Full Text PDF

We have developed a multi-region spherical Monte Carlo (MC) model to simulate the dynamic changes in light intensity measured during laser interstitial thermal therapy (LITT). Model predictions were validated experimentally in tissue-simulating albumen phantoms with well-characterized optical properties that vary dynamically with LITT in a way similar to tissue. For long treatments (2.

View Article and Find Full Text PDF