Publications by authors named "William B Moskowitz"

We aimed to study the disparity in the clinical profile and outcomes of hospitalized Multisystem Inflammatory Syndrome in Children (MIS-C) patients at our center. The second goal was to examine the temporal association with preceding SARS-CoV-2 infection by race/ethnicity in our community in Mississippi. We found the racial disparity in the prevalence of MIS-C exceeded its temporal association with SARS-CoV-2 infections.

View Article and Find Full Text PDF

This retrospective study included children aged ≤18 years who had durable ventricular assist devices (VADs) as a bridge to transplantation from the United Network Organ Sharing (UNOS) database between 2011 and 2020. We evaluated 90 day waitlist mortality and 1 year posttransplant mortality after VAD implantation in children stratified by race/ethnicity: Black, White, and Others. The VAD was used in a higher proportion of Black children listed for heart transplantation (HT) (26%) versus Other (25%) versus White (22%); p < 0.

View Article and Find Full Text PDF

The use of telehealth technology to connect with patients has expanded significantly over the past several years, particularly in response to the global coronavirus disease 2019 pandemic. This technical report describes the present state of telehealth and its current and potential applications. Telehealth has the potential to transform the way care is delivered to pediatric patients, expanding access to pediatric care across geographic distances, leveraging the pediatric workforce for care delivery, and improving disparities in access to care.

View Article and Find Full Text PDF

All children and adolescents deserve access to quality health care regardless of their race/ethnicity, health conditions, financial resources, or geographic location. Despite improvements over the past decades, severe disparities in the availability and access to high-quality health care for children and adolescents continue to exist throughout the United States. Economic and racial factors, geographic maldistribution of primary care pediatricians, and limited availability of pediatric medical subspecialists and pediatric surgical specialists all contribute to inequitable access to pediatric care.

View Article and Find Full Text PDF

This is a cross-sectional study of 29 published cases of acute myopericarditis following COVID-19 mRNA vaccination. The most common presentation was chest pain within 1-5 days after the second dose of mRNA COVID-19 vaccination. All patients had an elevated troponin.

View Article and Find Full Text PDF

This review discusses the potential drug and device therapies for pediatric heart failure (HF) due to reduced systolic function. It is important to realize that most drugs that are used in pediatric HF are extrapolated from adult cardiology practices or consensus guidelines based on expert opinion rather than on evidence from controlled clinical trials. It is difficult to conclude whether the drugs that are well established in adult HF trials are also beneficial for children because of tremendous heterogeneity in the mechanism of HF in children and variations in the pharmacokinetics and pharmacodynamics of drugs from birth to adolescence.

View Article and Find Full Text PDF

Objective: To update pediatric subspecialty workforce data to support evidence-based legislation and public policy decisions by replicating the American Academy of Pediatrics' 1998 Future of Pediatric Education (FOPE II) workforce survey.

Methods: A descriptive and comparative analysis of survey responses from 9950 US pediatric subspecialists who completed an electronic survey.

Results: Pediatric subspecialists are working fewer hours and spending less of their time in direct patient care than they did in 1998 but the mean hours worked differs significantly according to subspecialty.

View Article and Find Full Text PDF

Background: Limited therapeutic options are available for Fontan patients with dysfunctional or failing single ventricle physiology. This study describes the evaluation of an alternative, non-invasive, at-home therapeutic compression treatment for Fontan patients. Our hypothesis is that routinely administered, externally applied compression treatments to the lower extremities will augment systemic venous return, improve ventricular preload, and thus enhance cardiac output in Fontan patients.

View Article and Find Full Text PDF

The use of mechanical circulatory support (MCS) devices is a viable therapeutic treatment option for patients with congestive heart failure. Ventricular assist devices, cavopulmonary assist devices, and total artificial heart pumps continue to gain acceptance as viable treatment strategies for both adults and pediatric patients as bridge-to-transplant, bridge-to-recovery, and longer-term circulatory support alternatives. We present a review of the current and future MCS devices for patients having congenital heart disease (CHD) with biventricular or univentricular circulations.

View Article and Find Full Text PDF

The use of telemedicine technologies by primary care pediatricians, pediatric medical subspecialists, and pediatric surgical specialists (henceforth referred to as "pediatric physicians") has the potential to transform the practice of pediatrics. The purpose of this policy statement is to describe the expected and potential impact that telemedicine will have on pediatric physicians' efforts to improve access and physician workforce shortages. The policy statement also describes how the American Academy of Pediatrics can advocate for its members and their patients to best use telemedicine technologies to improve access to care, provide more patient- and family-centered care, increase efficiencies in practice, enhance the quality of care, and address projected shortages in the clinical workforce.

View Article and Find Full Text PDF

Mechanical assistance of the Fontan circulation is hypothesized to enhance ventricular preload and improve cardiac output; however, little is known about the fluid dynamics. This study is the first to investigate the three-dimensional flow conditions of a blood pump in an anatomic Fontan. Laser measurements were conducted having an axial flow impeller in the inferior vena cava.

View Article and Find Full Text PDF
Article Synopsis
  • * Three new pump designs were tested, with the top-performing Rec design showing significant pressure performance and low blood damage indices, making it more effective than the others studied.
  • * Numerical predictions of the pump's performance were mostly accurate in prototype testing, indicating it can support Fontan patients with minimal risk of blood trauma.
View Article and Find Full Text PDF

Single ventricle anomalies are a challenging set of congenital heart defects that require lifelong clinical management due to progressive decline of cardiovascular function. Few therapeutic devices are available for these patients, and conventional blood pumps are not designed for the unique anatomy of the single ventricle physiology. To address this unmet need, we are developing an axial flow blood pump with a protective cage or stent for Fontan patients.

View Article and Find Full Text PDF

A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs.

View Article and Find Full Text PDF

Background: This study investigated the application of circumferentially applied, external pressure to the lower extremities as a preventative measure and long-term clinical treatment strategy for Fontan patients.

Objective: We hypothesized that the application of circumferential pressure to the lower limbs will augment venous return and thus cardiac output.

Methods: Two patients (an extra-cardiac and intra-atrial Fontan) were evaluated.

View Article and Find Full Text PDF
Article Synopsis
  • * Current treatment options for plastic bronchitis lack proven effectiveness from controlled clinical trials.
  • * The study discusses using aerosolised heparin, known to help with other lung diseases, as a potential treatment for plastic bronchitis in a Fontan patient.
View Article and Find Full Text PDF

This numerical study examined the performance of an intravascular axial flow blood pump for mechanical hemodynamic support of patients in the setting of Fontan failure, which presently has few treatment options. Three anatomically accurate geometries of the total cavopulmonary connection (TCPC) were generated using patients' magnetic resonance imaging data. These patient-specific geometries, as well as an idealized version with cylindrical vessels, were computationally analyzed with and without a pump in the inferior vena cava.

View Article and Find Full Text PDF

Thousands of mechanical blood pumps are currently providing circulatory support, and the incidence of their use continues to increase each year. As the use of blood pumps becomes more pervasive in the treatment of those patients with congestive heart failure, critical advances in design features to address known limitations and the integration of novel technologies become more imperative. To advance the current state-of-the-art in blood pump design, this study investigates the inclusion of pitch-adjusting blade features in intravascular blood pumps as a means to increase energy transfer; an approach not explored to date.

View Article and Find Full Text PDF

Background: Cardiac asthma describes symptoms of airflow obstruction due to heart failure. Chronic heart failure is associated with decreased FEV 1 , and FEV 1 improves after heart transplantation. Fibrotic remodeling of the heart and airways is mediated, in part, through transforming growth factor (TGF)- β .

View Article and Find Full Text PDF

Objective: Advances in the geometric design of blood-contacting components are critically important as the use of minimally invasive, intravascular blood pumps becomes more pervasive in the treatment of adult and pediatric patients with congestive heart failure. The present study reports on the evaluation of uniquely shaped filaments and diffuser blades in the development of a protective stent for an intravascular cavopulmonary assist device for patients with a single ventricle.

Methods: We performed numeric modeling, hydraulic testing of 11 stents with an axial flow blood pump, and blood bag experiments (n = 6) of the top-performing stent geometries to measure the levels of hemolysis.

View Article and Find Full Text PDF

This study investigated the performance of a magnetically levitated, intravascular axial flow blood pump for mechanical circulatory support of the thousands of Fontan patients in desperate need of a therapeutic alternative. Four models of the extracardiac, total cavopulmonary connection (TCPC) Fontan configuration were evaluated to formulate numerical predictions: an idealized TCPC, a patient-specific TCPC per magnetic resonance imaging data, and each of these two models having a blood pump in the inferior vena cava (IVC). A lumped parameter model of the Fontan physiology was used to specify boundary conditions.

View Article and Find Full Text PDF

Background: Pediatric physicians regularly face the problem of uncertain procedural anticoagulation in children, especially in neonates. We sought to evaluate the safety, plasma concentration (pharmacokinetics, PK), pharmacodynamics (PD), and dosing guidelines of bivalirudin when used as a procedural anticoagulant in pediatric percutaneous intravascular procedures.

Methods And Results: Pediatric subjects undergoing percutaneous intravascular procedures for congenital heart disease were enrolled and received the current weight-based dose used in percutaneous coronary interventions (0.

View Article and Find Full Text PDF

This study evaluated the performance of an intravascular, percutaneously-inserted, axial flow blood pump in an idealized total cavopulmonary connection (TCPC) model of a Fontan physiology. This blood pump, intended for placement in the inferior vena cava (IVC), is designed to augment pressure and blood flow from the IVC to the pulmonary circulation. Three different computational models were examined: (i) an idealized TCPC without a pump; (ii) an idealized TCPC with an impeller pump; and (iii) an idealized TCPC with an impeller and diffuser pump.

View Article and Find Full Text PDF

Currently available mechanical circulatory support systems are limited for adolescent and adult patients with a Fontan physiology. To address this growing need, we are developing a collapsible, percutaneously-inserted, axial flow blood pump to support the cavopulmonary circulation in Fontan patients. During the first phase of development, the design and experimental evaluation of an axial flow blood pump was performed.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionprpdp8bat6jaqash058mupdht77v2qgo): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once