Purpose: Contrast-enhanced imaging of the breast is frequently used in breast MRI and has recently become more common in mammography. The purpose of this study was to make single-scan contrast-enhanced imaging feasible for photon-counting breast CT (pcBCT) and to assess the spectral performance of a pcBCT scanner by evaluating iodine maps and virtual non-contrast (VNC) images.
Methods: We optimized the settings of a pcBCT to maximize the signal-to-noise ratio between iodinated contrast agent and breast tissue.
Objectives: The purpose of this work is to present the data obtained from the first clinical in vivo application of a new dedicated spiral breast computed tomography (B-CT) equipped with a photon-counting detector.
Materials And Methods: The institutional review board approved this retrospective study. Twelve women referred for breast cancer screening were included and underwent bilateral spiral B-CT acquired in prone position.
Objectives: The performance of metal artifact reduction (MAR) methods in x-ray computed tomography (CT) suffers from incorrect identification of metallic implants in the artifact-affected volumetric images. The aim of this study was to investigate potential improvements of state-of-the-art MAR methods by using prior information on geometry and material of the implant.
Materials And Methods: The influence of a novel prior knowledge-based segmentation (PS) compared with threshold-based segmentation (TS) on 2 MAR methods (linear interpolation [LI] and normalized-MAR [NORMAR]) was investigated.
The increase in the radiation exposure from CT examinations prompted the investigation on the various dose-reduction techniques. Significant dose reduction has been achieved and the level of radiation exposure of thoracic CT is expected to reach the level equivalent to several chest X-ray examinations. With more scanners with advanced dose reduction capability deployed, knowledge on the radiation dose reduction methods has become essential to clinical practice as well as academic research.
View Article and Find Full Text PDFIntroduction: Recent studies have shown a substantial reduction of radiation dose from computed tomography (CT) scans down to 0.1 mSv for lung cancer screening and cardiac examinations, when applying optimization techniques. Hence, CT localizer radiographs (LRs) might now be considered a significant contributor to the total dose of the CT examination.
View Article and Find Full Text PDFUnlabelled: X-ray computed tomography (CT) has been proposed and evaluated multiple times as a potentially alternative method for breast imaging. All efforts shown so far have been criticized and partly disapproved because of their limited spatial resolution and higher patient dose when compared to mammography. Our concept for a dedicated breast CT (BCT) scanner therefore aimed at novel apparatus and detector design to provide high spatial resolution of about 100 μm and average glandular dose (AGD) levels of 5 mGy or below.
View Article and Find Full Text PDFObjectives: Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized.
View Article and Find Full Text PDFAims: The potential of dedicated Breast-CT is evaluated by simulating its impact onto the performance of the German breast cancer screening program. Attendance rates, cancer detection and economic implications are quantified.
Methods: Based on a prospective health technology assessment approach, we simulated screening in different scenarios.
Purpose: To investigate the dose saving potential of direct-converting CdTe photon-counting detector technology for dedicated breast CT.
Materials And Methods: We analyzed the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of two detector technologies, suitable for breast CT (BCT): a flat-panel energy-integrating detector with a 70 μm and a 208 μm thick gadolinium oxysulfide (GOS) and a 150 μm thick cesium iodide (CsI) scintillator and a photon-counting detector with a 1000 μm thick CdTe sensor.
Results: The measurements for GOS scintillator thicknesses of 70 μm and 208 μm delivered 10% pre-sampled MTF values of 6.
Articular cartilage and subchondral bone are the key tissues in osteoarthritis (OA). The role of the cancellous bone increasingly attracts attention in OA research. Because of its fast adaptation to changes in the loading distribution across joints, its quantification is expected to improve the diagnosis and monitoring of OA.
View Article and Find Full Text PDFThe estimation of patient dose using Monte Carlo (MC) simulations based on the available patient CT images is limited to the length of the scan. Software tools for dose estimation based on standard computational phantoms overcome this problem; however, they are limited with respect to taking individual patient anatomy into account. The purpose of this study was to generate whole-body patient models in order to take scattered radiation and over-scanning effects into account.
View Article and Find Full Text PDFThe purpose of this study was to validate the use of a single shaped filter (SF) for computed tomography (CT) using variable source-to-filter distance (SFD) for the examination of different object diameters.A SF was designed by performing simulations with the purpose of achieving noise homogeneity in the reconstructed volume and dose reduction for arbitrary phantom diameters. This was accomplished by using a filter design method thats target is to achieve a homogeneous detector noise, but also uses a correction factor for the filtered back projection process.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
November 2015
The aim of this study was the registration of digitized thin 2D sections of mouse vertebrae and tibiae used for histomorphometry of trabecular bone structure into 3D micro computed tomography (μCT) datasets of the samples from which the sections were prepared. Intensity-based and segmentation-based registrations (SegRegs) of 2D sections and 3D μCT datasets were applied. As the 2D sections were deformed during their preparation, affine registration for the vertebrae was used instead of rigid registration.
View Article and Find Full Text PDFPurpose: To determine the dose-length product (DLP)-effective dose (ED) (DLP/ED) conversion coefficient (k) tables for the lower extremities that can be used for calculating ED.
Materials And Methods: Dose calculations were performed on standard phantoms using a validated Monte Carlo calculation tool. Calculations were performed to obtain ED values for tube voltages from 80 kV to 140 kV in steps of 20 kV for the following examinations: hip (femur), knee, ankle, and computed tomographic (CT) angiography of the lower extremities.
Objectives: Dynamic contrast-enhanced (DCE) micro-computed tomography (micro-CT) has emerged as a valuable imaging tool to noninvasively obtain quantitative physiological biomarkers of drug effect in preclinical studies of antiangiogenic compounds. In this study, we explored the ability of DCE micro-CT to assess the antiangiogenic treatment response in breast cancer xenografts and correlated the results to the structural vessel response obtained from 3-dimensional (3D) fluorescence ultramicroscopy (UM).
Material And Methods: Two groups of tumor-bearing mice (KPL-4) underwent DCE micro-CT imaging using a fast preclinical dual-source micro-CT system (TomoScope Synergy Twin, CT Imaging GmbH, Erlangen, Germany).
Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT.
View Article and Find Full Text PDFRadiation dose in x-ray computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. This review aims to present an overview of current concepts for both scanner output metrics and for patient dosimetry and will comment on their strengths and weaknesses. Controversial issues such as the appropriateness of the CT dose index (CTDI) are discussed in detail.
View Article and Find Full Text PDFEvid Based Complement Alternat Med
August 2013
In female subjects, ageing and the menopausal transition contribute to a rapid increase of metabolic and cardiac risk factors. Exercise may be an option to positively impact various risk factors prone to severe metabolic and cardiac diseases and events. This study was conducted to determine the long-term effect of a multipurpose exercise program on metabolic and cardiac risk scores in postmenopausal women.
View Article and Find Full Text PDFPurpose: With recently introduced technical innovations for CT systems, the dose of CT scan acquisitions has been substantially reduced; even effective dose values below 1 mSv have been reported. Due to this development, dose of the localizer radiograph may contribute substantially to dose of the whole CT examination. Since there are only limited data in the literature regarding patient dose for the different types of localizer radiographs, patient dose values were estimated in our study by measurements and Monte Carlo simulations and compared to dose values of typical CT examinations.
View Article and Find Full Text PDFThe purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose and image quality. Optimization of filter shape and material in fan direction was performed using two different design methods, one aiming at homogeneous noise distributions in the CT images and the other aiming at a uniform dose distribution in the breast. The optimal filter thickness as a function of fan angle was determined iteratively to fulfil the above mentioned criteria for each breast diameter.
View Article and Find Full Text PDFObjectives: Integrated whole-body positron emission tomography (PET)/magnetic resonance (MR) scanners have recently been introduced and potentially offer new possibilities in hybrid imaging of oncologic patients. Integration of PET in a whole-body MR system requires new PET detector technology and new approaches to attenuation correction of PET data based on MR imaging. The aim of this study was to evaluate the clinical performance and image quality parameters of integrated whole-body PET/MR hybrid imaging in intraindividual comparison with PET/CT in oncologic patients.
View Article and Find Full Text PDFIn this research a fully sensorized cooperative robot system for manipulation of needles is presented. The setup consists of a DLR/KUKA Light Weight Robot III especially designed for safe human/robot interaction, a FD-CT robot-driven angiographic C-arm system, and a navigation camera. Also, new control strategies for robot manipulation in the clinical environment are introduced.
View Article and Find Full Text PDFPurpose: Misalignment artifacts are a serious problem in medical flat-detector computed tomography. Generally, the geometrical parameters, which are essential for reconstruction, are provided by preceding calibration routines. These procedures are time consuming and the later use of stored parameters is sensitive toward external impacts or patient movement.
View Article and Find Full Text PDFPurpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality.
Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD).
Purpose: Monte Carlo (MC) simulation is an established technique for dose calculation in diagnostic radiology. The major drawback is its high computational demand, which limits the possibility of usage in real-time applications. The aim of this study was to develop fast on-site computed tomography (CT) specific MC dose calculations by using a graphics processing unit (GPU) cluster.
View Article and Find Full Text PDF