Hard X-ray free-electron lasers (XFELs) generate intense coherent X-ray beams by passing electrons through undulators, i.e. very long periodic magnet structures, which extend over hundreds of meters.
View Article and Find Full Text PDFThe pre-existing ORNL scrape-off-layer (SOL) reflectometer that operated with the X-mode R-cutoff at 6-27 GHz to measure SOL density profiles on NSTX is being upgraded to be functional at the increased magnetic fields on NSTX-U spherical tokamak. Rather than increasing the operating frequencies to measure the higher X-mode R-cutoff frequencies on NSTX-U, it will be shown that the combined use of the X-mode R, L and O-mode cutoffs at 6-27 GHz can obtain the desired SOL density profiles. The potential capabilities and obstacles of this technique to measure SOL density profiles and possibly SOL magnetic field profiles on NSTX-U will be discussed.
View Article and Find Full Text PDFA swept-frequency X-mode reflectometer has been built on Alcator C-Mod to measure the scrape-off layer (SOL) density profiles adjacent to the lower hybrid launcher. The reflectometer system operates between 100 and 146 GHz at sweep rates from 10 μs to 1 ms and covers a density range of ∼10(16)-10(20) m(-3) at B(0) = 5-5.4 T.
View Article and Find Full Text PDFRev Sci Instrum
October 2010
A critical issue in the design of the ITER low field side reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of ∼42 m of corrugated waveguide and up to ten miter bends.
View Article and Find Full Text PDFA swept-frequency X-mode reflectometer is being built for Alcator C-Mod to measure the scrape-off layer density profiles at the top, middle, and bottom locations in front of both the new lower hybrid launcher and the new ion cyclotron range of frequencies antenna. The system is planned to operate between 100 and 146 GHz at sweep rates from 10 μs to 1 ms, and will cover a density range of approximately 10(16)-10(20) m(-3) at B(0)=5-5.4 T.
View Article and Find Full Text PDFMicrowave reflectometry will be used on ITER to measure the electron density profile, density fluctuations due to MHD/turbulence, edge localized mode (ELM) density transients, and as an L-H transition monitor. The ITER low field side reflectometer system will measure both core and edge quantities using multiple antenna arrays spanning frequency ranges of 15-155 GHz for the O-mode system and 55-220 GHz for the X-mode system. Optimization studies using the GENRAY ray-tracing code have been done for edge and core measurements.
View Article and Find Full Text PDFA two-frequency x-mode reflectometer operating from 100 to 146 GHz is deployed on Alcator C-Mod to measure the density profile and fluctuations in the scrape-off layer (SOL) immediately in front of the new J-port ICRF antenna and the new C-port lower hybrid launcher. The reflectometer covers densities from 10(16) to 10(20) m(-3) at 5-5.4 T.
View Article and Find Full Text PDFNational Spherical Torus Experiment (NSTX) is a spherical tokamak (ST) that operates with n(e) up to 10(20) m(-3) and B(T) less than 0.6 T, cutting off low harmonic electron cyclotron (EC) emission widely used for T(e) measurements on conventional aspect ratio tokamaks. The electron Bernstein wave (EBW) can propagate in ST plasmas and is emitted at EC harmonics.
View Article and Find Full Text PDFIn the present paper, abnormal feather development associated with an in ovo avian leukosis virus (ALV) subgroup J infection in specific pathogen free broilers is reported. A description of gross lesions is given, together with the results of light microscopic, immunohistochemical and ultrastructural studies to further elucidate the characteristics of the feather pathology and to assess the presence of ALV subtype J in broiler feathers. The feather lesions found, which were mainly restricted to primary and secondary remiges, were thinness and increased transparency of the calamus and sparseness of the vane.
View Article and Find Full Text PDF