Int J Oral Maxillofac Implants
May 2019
Purpose: This study investigated the effect of fracture strength and fracture mode characteristics related to reduced interocclusal space on computer-aided design/computer-aided manufacturing (CAD/CAM). ZrO fixed partial denture (FPD) frameworks subjected to quasi-static loads.
Materials And Methods: First, two dental implants (4 × 10 mm) were positioned simulating a three-unit FPD (second premolar and second molar abutments).
Objectives: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading.
Material And Methods: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant.
J Dent Educ
November 2010
This study aimed to evaluate the knowledge of senior dental students about mouth preparation and removable partial denture (RPD) design. Two hundred sixty-six senior students from eleven dental schools in the State of São Paulo, Brazil, comprised the sample. The subjects examined two partially edentulous casts mounted on a semiadjustable articulator, answered a questionnaire regarding the treatment plan, and drew the RPD design.
View Article and Find Full Text PDFPurpose: The purpose of this review was to highlight anatomic and biomechanical aspects of atrophic maxillae for implant possibilities.
Materials And Methods: A MEDLINE electronic search of the years 1966 to 2009 was conducted with the keywords "atrophic,""resorbed,""edentulous," and "maxilla."
Results: Twenty papers presented the following findings: (1) previous use of a removable prosthesis is a risk factor for resorption, with flabby tissues related to the severity of resorption; (2) implants in the reconstructed maxilla (< or =5 mm) and supporting overdentures had a higher risk for bone loss based on the worse periimplant soft-tissue health observed; (3) bleeding on probing was found with pocket depths > or =5 mm in half of the zygomatic implants; (4) prevalence of bone septa is higher in atrophic maxillae, and changes on nasopalatine canal can reduce up to 44.
Individuals with temporomandibular disorders (TMD) are expected to have decreased maximum bite forces (MBF). This way, this study compared the MBF in subjects with TMD to a control group and also evaluated its association with age, gender, height and weight. Forty healthy adults with complete natural dentition divided into four groups according to gender and presence or absence of TMD signs/symptoms (based on the Research Diagnostic Criteria RDC) underwent a MBF test with a gnathodynamometer in molar and incisal areas.
View Article and Find Full Text PDFUnlabelled: Mouth floor enlargements (MFE) are observed in edentulous and partially edentulous patients, impairing denture fitting, and have recently been described in the literature as hyperplasias of the sublingual glands.
Objective: This study aims at describing the microscopic aspects of MFE that contribute to their final diagnosis.
Methods: Twenty-four specimens were surgically removed from the enlarged mouth floor of 19 patients (15 females and 4 males).
Unlabelled: Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws.
Objectives: To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding.
Methods: After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars.
Statement Of Problem: The bond strength of composite resin cores to the smooth surface of prefabricated zirconia-based ceramic posts is problematic because it might not be sufficient to ensure stability of the post-and-core system. It is also not clear whether any alteration of the post surface to provide additional mechanical or chemical retention would compromise flexural strength of the posts.
Purpose: This study tested the effect of a tribochemical treatment on the bond strength (BS) between zirconia-based ceramic posts and composite resin and on the flexural strength (FS) of the posts.
The aim of this study was to measure marginal fit at cylinder-abutment interface, before and after overcasting procedure. A hexagonal implant was fixed to a stainless steel base and a Estheticone-like abutment used during all the experiment. Before casting procedure, gold (Group I) and Ni-Cr-Be (Group II) premachined cylinders were tightened to the abutment with gold and titanium screws (in both groups), with 10Ncm and 20Ncm torque values for the same screw type.
View Article and Find Full Text PDFJ Appl Oral Sci
June 2005
Objectives: The aim of this study was to evaluate the influence of remaining coronal tooth structure on endodontically treated teeth restored with prefabricated posts and two different composites for core build-up: dual-cured resin (Enforce Core) and light-cured resin (Z-250).
Methods: Fourty freshly extracted canines were endodontically treated and divided into four groups: Group I - teeth with 3mm remaining coronal structure, restored with Enforce Core; Group II - teeth with 3mm remaining coronal structure, restored with Z-250; Group III - teeth with no remaining coronal structure, restored with Enforce; Group IV - teeth with no remaining coronal structure, restored with Z-250. After restoration, the teeth were embedded in acrylic resin and the fracture resistance was measured on a universal testing machine at 45 degrees to the long axis of the tooth until failure.
The aim of this study was to evaluate and compare the retentive capacity between two O-ring and O-SO system (Group I), and two ERA system types - white and gray retention caps - (Group II), respectively, in simulated function in database, 6 months, 1, 2, 3, 4, and 5 years later, with insertion and removal cycles. Two Brånemark implants were fixed in two trapezoidal metallic bases for the tests. Removal and insertion tests were done in a sewing machine, adjusted for this purpose using a belt and a pulley system, moving a steel crankshaft.