Publications by authors named "Weiye Song"

Deep learning, particularly convolutional neural networks (CNNs), has revolutionized endoscopic image processing, significantly enhancing the efficiency and accuracy of disease diagnosis through its exceptional ability to extract features and classify complex patterns. This technology automates medical image analysis, alleviating the workload of physicians and enabling a more focused and personalized approach to patient care. However, despite these remarkable achievements, there are still opportunities to further optimize deep learning models for endoscopic image analysis, including addressing limitations such as the requirement for large annotated datasets and the challenge of achieving higher diagnostic precision, particularly for rare or subtle pathologies.

View Article and Find Full Text PDF

The nanofiber materials of three-dimensional spatial structure synthesized by electrospun have the characteristics of high porosity, high specific surface area, and high similarity to the natural extracellular matrix (ECM) of the human body. These are beneficial for absorbing wound exudate, effectively blocking the invasion of external bacteria, and promoting cell respiration and proliferation, which provides an ideal microenvironment for wound healing. Moreover, electrospun nanofiber dressings can flexibly load drugs according to the condition of the wound, further promoting wound healing.

View Article and Find Full Text PDF

Self-Biased Magnetic Pendulum Array (SBMPA) is an efficient and portable transmitter in ultralow frequency (ULF). The resonance frequency of SBMPA is affected by the magnetic field of the radially magnetized cylindrical permanent magnets. In order to calculate the resonance frequency, the magnetic field model of a single radially magnetized cylindrical permanent magnet is derived based on the concept of magnetic charge.

View Article and Find Full Text PDF

Accurate segmentation of retinal layer boundaries can facilitate the detection of patients with early ophthalmic disease. Typical segmentation algorithms operate at low resolutions without fully exploiting multi-granularity visual features. Moreover, several related studies do not release their datasets that are key for the research on deep learning-based solutions.

View Article and Find Full Text PDF

Purpose: To evaluate the clinical utility of visible light optical coherence tomography (VIS-OCT) and to test whether VIS-OCT reflectivity and spectroscopy of peripapillary retinal nerve fiber layer (pRNFL) are correlated with severity of glaucoma, compared with standard-of-care OCT thickness measurements.

Methods: In total 54 eyes (20 normal, 17 suspect/preperimetric glaucoma [GS/PPG], 17 perimetric glaucoma [PG]) were successfully imaged with complete datasets. All the eyes were scanned by a custom-designed dual-channel device that simultaneously acquired VIS-OCT and near-infrared OCT (NIR-OCT) images.

View Article and Find Full Text PDF

Autoinhibition of kinesin-3 ensures the proper spatiotemporal control of the motor activity for intracellular transport, but the underlying mechanism remains elusive. Here, we determine the full-length structure of kinesin-3 KLP-6 in a compact self-folded state. Unexpectedly, all the internal coiled-coil segments and domains in KLP-6 cooperate to successively lock down the neck and motor domains.

View Article and Find Full Text PDF

The retinal macula is at the center of our visual field, and thus pathological damage in the macula significantly impacts an individual's quality of life. The parafoveal vessels form the inner retina provide oxygen perfusion, and the measurement of parafoveal oxygen saturation (sO) can evaluate macular metabolism and provide pathophysiological insight. In this paper, for the first time, we present a baseline study of microvascular oxygen saturation (sO) in perifoveal macular region using visible light optical coherence tomography (VIS-OCT) on normal eyes.

View Article and Find Full Text PDF

Traditional imaging cytometry uses fluorescence markers to identify specific structures but is limited in throughput by the labeling process. We develop a label-free technique that alleviates the physical staining and provides multiplexed readouts via a deep learning-augmented digital labeling method. We leverage the rich structural information and superior sensitivity in reflectance microscopy and show that digital labeling predicts accurate subcellular features after training on immunofluorescence images.

View Article and Find Full Text PDF

We report herein the first visible light optical coherence tomography angiography (vis-OCTA) for human retinal imaging. Compared to the existing vis-OCT systems, we devised a spectrometer with a narrower bandwidth to increase the spectral power density for OCTA imaging, while retaining the major spectral contrast in the blood. We achieved a 100 kHz A-line rate, the fastest acquisition speed reported so far for human retinal vis-OCT.

View Article and Find Full Text PDF

LED array microscopy is an emerging platform for computational imaging with significant utility for biological imaging. Existing LED array systems often exploit transmission imaging geometries of standard brightfield microscopes that leave the rich backscattered field undetected. This backscattered signal contains high-resolution sample information with superb sensitivity to subtle structural features that make it ideal for biological sensing and detection.

View Article and Find Full Text PDF

Oblique scanning laser ophthalmoscopy (oSLO) is a novel imaging modality to provide volumetric retinal imaging without depth sectioning over a large field of view (FOV). It has been successfully demonstrated in vivo in rodent eyes for volumetric fluorescein angiography (vFA). However, engineering oSLO for human retinal imaging is challenging because of the low numerical aperture (NA) of human ocular optics.

View Article and Find Full Text PDF

Oblique scanning laser ophthalmoscopy (oSLO) is a recently developed technique to provide three-dimensional volumetric fluorescence imaging in retinas over a large field of view, without the need for depth sectioning. In this study, we present volumetric fluorescein angiography (vFA) at 200 B-scans per second in mouse retina by oSLO. By using a low-cost industrial CMOS camera, imaging speed was improved to 2 volumes per second, ∼10 times more than our previous results.

View Article and Find Full Text PDF

The retina, as part of the central nervous system, has distinct anatomical and structural properties for its visual function. Light scattering spectroscopy, while widely used for tissue structural characterization and disease diagnosis, has been relatively unexplored in the living retina. Recently, we have developed a fiber-based visible and near-infrared optical coherence tomography system (vnOCT) for retinal imaging, to uniquely measure a spectroscopic marker (VN ratio) sensitive to nanoscale pathological changes.

View Article and Find Full Text PDF

H- and Nb-doped ZnO (HNZO) thin films were fabricated on glass substrates with radio frequency magnetron sputtering. The effect of the flow rate of H has been investigated by analyzing the structural, optical, and electrical properties. The incorporation of H during the deposition of Nb-incorporated ZnO films significantly improved their crystallinity, conductivity, and transmittance.

View Article and Find Full Text PDF

Biological functions rely on local microvasculature to deliver oxygen and nutrients and carry away metabolic waste. Alterations to local oxygenation levels are manifested in diseases including cancer, diabetes mellitus, etc. The ability to quantify oxygen saturation (sO) within microvasculature to assess local tissue oxygenation and metabolic function is highly sought after.

View Article and Find Full Text PDF

While fluorescence imaging is widely used in ophthalmology, a large field of view (FOV) three-dimensional (3D) fluorescence retinal image is still a big challenge with the state-of-the-art retinal imaging modalities because they would require z-stacking to compile a volumetric dataset. Newer optical coherence tomography (OCT) and OCT angiography (OCTA) systems overcome these restrictions to provide three-dimensional (3D) anatomical and vascular images, but the dye-free nature of OCT cannot visualize leakage indicative of vascular dysfunction. This protocol describes a novel oblique scanning laser ophthalmoscopy (oSLO) technique that provides 3D volumetric fluorescence retinal imaging.

View Article and Find Full Text PDF

Elastic light scattering spectroscopy (ELSS) has been proven a powerful method in measuring tissue structures with exquisite nanoscale sensitivity. However, ELSS contrast in the living human retina has been relatively underexplored, primarily due to the lack of imaging tools with a large spectral bandwidth. Here, we report a simple all fiber-based setup to implement dual-channel visible and near infrared (NIR) optical coherence tomography (vnOCT) for human retinal imaging, bridging over a 300nm spectral gap.

View Article and Find Full Text PDF

Flow-mediated vasodilation (FMD) is used for assessment of vascular endothelial function in humans as a predictor of cardiovascular events. It has been challenging to carry it on preclinical murine models due to the diminutive size of the femoral artery. Here, we present a new approach to accurately measure the blood velocity and femoral artery diameters of mice by acquiring Doppler optical coherence tomography and optical coherence tomography angiography continuously within 1 single experimental scanning protocol.

View Article and Find Full Text PDF

While fluorescent contrast is widely used in ophthalmology, three-dimensional (3D) fluorescence retinal imaging over a large field of view (FOV) has been challenging. In this paper, we describe a novel oblique scanning laser ophthalmoscopy (oSLO) technique that provides 3D volumetric fluorescence retinal imaging with only one raster scan. The technique utilizes scanned oblique illumination and angled detection to obtain fluorescent cross-sectional images, analogous to optical coherence tomography (OCT) line scans (or B-scans).

View Article and Find Full Text PDF

Optical nanomaterials with intense absorption in near-infrared (NIR) region hold great promise for biomedical applications such as photothermal therapy (PTT) and photoacoustic imaging (PAI). In this work, we report mesoporous carbon nanospheres (Meso-CNs) with broadband and intense absorption in the UV-Vis-NIR region (300-1400 nm) and explore their potential as a multifunctional platform for photoacoustic imaging and chemo-photothermal therapy. Meso-CNs were prepared by a "silica-assisted" synthesis strategy and characterized by transmission electron microscope and optical spectroscopy.

View Article and Find Full Text PDF

In this paper, we present the first numerical study on full metrics of wavelength-dependent optical properties of melanosomes in retinal pigmented epithelial (RPE) cells. T-matrix method was used to simulate the spheroidal shapes of mature melanosomes, and the complex refractive index was calculated by a subtractive Kramers-Kronig relation for melanin. The validity of the method was first confirmed by Mie theory, and corroborated by a comparison between visible light and near infrared (NIR) optical coherence tomography (OCT) on human retinal imaging.

View Article and Find Full Text PDF

Multi-modal three dimensional (3D) optical imaging combining both structural sensitivity and molecular specificity is highly desirable in biomedical research. In this paper, we present a method termed oblique scanning laser microscopy (OSLM) to combine optical coherence tomography (OCT), for simultaneously volumetric structural and molecular imaging with cellular resolution in all three dimensions. Conventional 3D laser scanning fluorescence microscopy requires repeated optical sectioning to create z-stacks in depth.

View Article and Find Full Text PDF

In this work, α-NaLuF4:Yb,Er (NLF) nanocomposites (NCs) and β-NLF NCs with diameter about ~13 nm were fabricated by a high temperature decomposition reaction method. The effects of NLF structure on the enhanced red upconversion luminescence performance were investigated. Under 980 nm excitation from a laser diode, the α-NLF emitted dominant red UC emission.

View Article and Find Full Text PDF

In this work the effects of NaYF4:Yb,Er (NYE) structure on the enhanced red upconversion luminescence (UC) was investigated. α-NYE nanocrystals (NCs) and β-NYE NCs were fabricated by a high temperature decomposition reaction method. The prepared NCs were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), and photoluminescence (PL) spectroscopy.

View Article and Find Full Text PDF

Gain characteristics of polymer waveguide amplifiers based on NaYF4:Yb3+, Er3+ nanocrystals (NCs) at 0.54 µm wavelength were investigated through numerical simulations. NaYF4:18%Yb3+, 1 0%Er3+ NCs were doped into SU-8 2005 polymer matrix as the core of a polymer waveguide.

View Article and Find Full Text PDF