Publications by authors named "Weiszflog M"

The TOFOR time-of-flight (TOF) neutron spectrometer at the Joint European Torus (JET) is composed of 5 start (S1) and 32 stop (S2) scintillation detectors. Recently, the data acquisition system (DAQ) of TOFOR was upgraded to equip each of the 37 detectors with its own waveform digitizer to allow for correlated time and pulse height analysis of the acquired data. Due to varying cable lengths and different pulse processing pathways in the new DAQ system, the 160 (5 · 32) different TOF pairs of start-stop detectors must be time-aligned to enable the proper construction of a summed TOF spectrum.

View Article and Find Full Text PDF

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted.

View Article and Find Full Text PDF

This paper presents two different conceptual designs of neutron cameras for Mega Ampere Spherical Tokamak (MAST) Upgrade. The first one consists of two horizontal cameras, one equatorial and one vertically down-shifted by 65 cm. The second design, viewing the plasma in a poloidal section, also consists of two cameras, one radial and the other one with a diagonal view.

View Article and Find Full Text PDF

The fuel ion ratio nt/nd is an essential parameter for plasma control in fusion reactor relevant applications, since maximum fusion power is attained when equal amounts of tritium (T) and deuterium (D) are present in the plasma, i.e., nt/nd = 1.

View Article and Find Full Text PDF

In this paper, we present a method to derive n(t)/n(d) using the ratio of the thermonuclear neutron emission to the beam-target neutron emission. We apply it to neutron spectroscopy data from the magnetic proton recoil spectrometer taken during the deuterium tritium experiment at JET. n(t)/n(d)-values obtained using neutron spectroscopy are in qualitative agreement with those from other diagnostics measuring the isotopic composition of the exhaust in the divertor.

View Article and Find Full Text PDF

A prototype of a fully digital data acquisition system based on 1 Gsps 12 bit digitizers for the TOFOR fusion neutron spectrometer at JET is assessed. The prototype system enables the use of geometry-based background discrimination techniques, which are modeled, evaluated, and compared to experimental data. The experimental results are in line with the models and show a significant improvement in signal-to-background ratio in measured time-of-flight spectrum compared to the existing data acquisition system.

View Article and Find Full Text PDF

A neutron camera with liquid scintillator detectors is used in MAST to measure the neutron emissivity from D(d,n)(3)He reactions along collimated lines of sight. In this work, the measured recoil proton pulse height spectra generated in the detectors by the incident neutrons is modelled taking into account the energy spectrum of the generated neutrons, their spatial distribution and transport to the detectors as well as the detector's response function. The contribution of scattered neutrons to the pulse height spectrum is also modelled.

View Article and Find Full Text PDF

In a fusion reactor with high energy gain, the fusion power will be mainly thermonuclear (THN). Measurements of the THN neutron rate are a good performance indicator of a fusion plasma, requiring neutron emission spectroscopy (NES) measurements to distinguish thermal and nonthermal contributions. We report here on recent NES results from JET high-performance plasmas with high fractions (about 65%) of THN emission.

View Article and Find Full Text PDF

Recent experiments at JET aimed at producing 4He ions in the MeV range through third harmonic ion cyclotron resonance heating (ICRH) acceleration of 4He beams in a 4He dominated plasma. MeV range D was also present through parasitic ICRH absorption on residual D. In this contribution, we analyze TOFOR neutron spectrometer data from these experiments.

View Article and Find Full Text PDF

The determination of the fuel ion ratio n(t)/n(d) in ITER is required at a precision of 20%, time resolution of 100 ms, spatial resolution of a/10, and over a range of 0.01 View Article and Find Full Text PDF

A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination.

View Article and Find Full Text PDF

Burning plasma experiments such as ITER and DEMO require diagnostics capable of withstanding the harsh environment generated by the intense neutron flux and to maintain stable operating conditions for times longer than present day systems. For these reasons, advanced control and monitoring (CM) systems will be necessary for the reliable operation of diagnostics. This paper describes the CM system of the upgraded magnetic proton recoil neutron spectrometer installed at the Joint European Torus focusing in particular on a technique for the stabilization of the gain of the photomultipliers coupled to the neutron detectors.

View Article and Find Full Text PDF

The effect of ion cyclotron resonance heating (ICRH) on (3He)D plasmas at JET was studied with the time of flight optimized rate (TOFOR) spectrometer dedicated to 2.5 MeV dd neutron measurements. In internal transport barrier (ITB) plasma experiments with large 3He concentrations (X(3He)>15%) an increase in neutron yield was observed after the ITB disappeared but with the auxiliary neutral beam injection and ICRH power still applied.

View Article and Find Full Text PDF

A determination of fast ion population parameters such as intensity and kinetic temperature is important for fusion reactors. This becomes more challenging with finer time resolution of the measurements, since the limited data in each time slice cause increasing statistical variations in the data. This paper describes a framework using Bayesian-regularized neural networks (NNs) designed for such a task.

View Article and Find Full Text PDF

A method to generate modeled neutron spectra from bulk and fast ion distributions simulated by TRANSP has been developed. In this paper, modeled data generated from fuel ion distributions modeled with TRANSP is compared to measured data from two neutron spectrometers with different lines of sight; TOFOR with a radial one and the MPRu with a tangential one. The information obtained from the analysis of the measured neutron spectra such as the relative intensity of the emission from different ion populations places additional constraints on the simulation and can be used to adjust the parameters of the simulation.

View Article and Find Full Text PDF

High resolution neutron spectrometers provide information about plasma parameters at existing fusion experiments. Such a system may also be employed at ITER. Proton recoil telescopes have classically been used to detect neutrons with good energy resolution but poor efficiency.

View Article and Find Full Text PDF

A rotational band with seven gamma-ray transitions between states with spin 2 Planck's constant and 16 Planck's constant has been observed in the doubly magic, self-conjugate nucleus (40)(20)Ca(20). The measured transition quadrupole moment of 1.80(+0.

View Article and Find Full Text PDF

Gamma rays from the N = Z-2 nucleus (50)Fe have been observed, establishing the rotational ground state band up to the state J(pi) = 11+ at 6.994 MeV excitation energy. The experimental Coulomb energy differences, obtained by comparison with the isobaric analog states in its mirror (50)Cr, confirm the qualitative interpretation of the backbending patterns in terms of successive alignments of proton and neutron pairs.

View Article and Find Full Text PDF