Publications by authors named "Weininger S"

Significance: Pulse oximeter measurements are commonly relied upon for managing patient care and thus often require human testing before they can be legally marketed. Recent clinical studies have also identified disparities in their measurement of blood oxygen saturation by race or skin pigmentation.

Aim: The development of a reliable bench-top performance test method based on tissue-simulating phantoms has the potential to facilitate pre-market assessment and the development of more accurate and equitable devices.

View Article and Find Full Text PDF

Pulse oximetry enables real-time, noninvasive monitoring of arterial blood oxygen levels. However, results can vary with skin color, thus detecting disparities during clinical validation studies requires an accurate measure of skin pigmentation. Recent clinical studies have used subjective methods such as self-reported color, race/ethnicity to categorize skin.

View Article and Find Full Text PDF

Pulse oximetry represents a ubiquitous clinical application of optics in modern medicine. Recent studies have raised concerns regarding the potential impact of confounders, such as variable skin pigmentation and perfusion, on blood oxygen saturation measurement accuracy in pulse oximeters. Tissue-mimicking phantom testing offers a low-cost, well-controlled solution for characterizing device performance and studying potential error sources, which may thus reduce the need for costly in vivo trials.

View Article and Find Full Text PDF

This paper explores the effect of the load imposed by implantable cardioverter defibrillators (ICDs) on their lithium battery power sources longevity using a simulation approach that incorporates a coupled electro-thermal dynamic model. ICDs are one of the effective treatments available to significantly improve survival of patients with fatal arrhythmia (abnormal heart rhythm) disorders. Using a lithium battery power source, this life-saving device sends electrical shocks or pulses to regulate the heartbeat.

View Article and Find Full Text PDF

In the human eye lenses, the crystallin proteins facilitate transparency, light refraction, as well as UV light protection. A deregulated balanced interplay between α-, β-, and γ-crystallin can cause cataract. γD-crystallin (hγD) is involved in the energy dissipation of absorbed UV light by energy transfer between aromatic side chains.

View Article and Find Full Text PDF

Clinical studies have demonstrated that epidermal pigmentation level can affect cerebral oximetry measurements. To evaluate the robustness of these devices, we have developed a phantom-based test method that includes an epidermis-simulating layer with several melanin concentrations and a 3D-printed cerebrovascular module. Measurements were performed with neonatal, pediatric and adult sensors from two commercial oximeters, where neonatal probes had shorter source-detector separation distances.

View Article and Find Full Text PDF

This article reports on the development of usability engineering recommendations for next-generation integrated interoperable medical devices. A model-based hazard analysis method is used to reason about possible design anomalies in interoperability functions that could lead to use errors. Design recommendations are identified that can mitigate design problems.

View Article and Find Full Text PDF

This article describes the concept of Medical Device Interface Data Sheets (MDIDSs) to document and characterize medical device interface data requirements, the processes for creating MDIDSs, and its role in supporting patient safety and cybersecurity of current systems while enabling innovation in the area of next-generation medical Internet of Things (IoT) platforms for integrating sensors, actuators, and applications (apps).

View Article and Find Full Text PDF

Cerebral oximetry based on near-infrared spectroscopy represents a unique noninvasive tool for real-time surgical monitoring, yet studies have shown a significant discrepancy in accuracy among commercial systems. Towards the establishment of a standardized method for performance testing, we have studied a solid phantom approach - based on a 3D-printed cerebrovascular module (CVM) incorporating an array of 148 cylindrical channels - that has several advantages over liquid phantoms. Development and characterization of a CVM prototype are described, including high-resolution imaging and spectrophotometry measurements.

View Article and Find Full Text PDF

Objective: This paper presents a hardware-in-the-loop (HIL) testing platform for evaluating the performance of fluid resuscitation control algorithms. The proposed platform is a cyber-physical system that integrates physical devices with computational models and computer-based algorithms.

Methods: The HIL test bed is evaluated against in silico and in vivo data to ensure the hemodynamic variables are appropriately predicted in the proposed platform.

View Article and Find Full Text PDF

Physiological closed-loop controlled medical devices automatically adjust therapy delivered to a patient to adjust a measured physiological variable. In critical care scenarios, these types of devices could automate, for example, fluid resuscitation, drug delivery, mechanical ventilation, and/or anesthesia and sedation. Evidence from simulations using computational models of physiological systems can play a crucial role in the development of physiological closed-loop controlled devices; but the utility of this evidence will depend on the credibility of the computational model used.

View Article and Find Full Text PDF

Physiological closed-loop controlled medical devices are safety-critical systems that combine patient monitors with therapy delivery devices to automatically titrate therapy to meet a patient's current need. Computational models of physiological systems can be used to test these devices and generate pre-clinical evidence of safety and performance before using the devices on patients. The credibility, utility, and acceptability of such model-based test results will depend on, among other factors, the computational model used.

View Article and Find Full Text PDF

The emergence of physical organic chemistry, which focuses on the mechanisms and structures of organic reactions and molecules using the tools of physical chemistry, was a major development in twentieth-century chemistry. It first flourished in the interwar period, in the UK and then in the US. Germany, by contrast, did not embrace the field until almost a half century later.

View Article and Find Full Text PDF

Inflammatory bowel diseases (IBDs) include Crohn's disease, and ulcerative colitis. preparations have beneficial effects for IBD patients. However, extracts contain hundreds of compounds.

View Article and Find Full Text PDF

Part of the mission of the Center for Devices and Radiological Health (CDRH) at the US Food and Drug Administration is to facilitate medical device innovation. Therefore, CDRH plays an important role in helping its stakeholders such as manufacturers, health care professionals, patients, patient advocates, academia, and other government agencies navigate the regulatory landscape for medical devices. This is particularly important for innovative physiological closed-loop controlled (PCLC) devices used in critical care environments, such as intensive care units, emergency settings, and battlefield environments.

View Article and Find Full Text PDF

The Hickrill Chemical Research Foundation, located north of New York City on the estate of its patrons, Sylvan and Ruth Alice Norman Weil, had a short (1948-59) but productive life. Ruth Alice Weil received a Ph.D.

View Article and Find Full Text PDF

This paper describes why "device state" and "patient context" information are necessary components of device models for safe interoperability. This paper includes a discussion of the importance of describing the roles of devices with respect to interactions (including human user workflows involving devices, and device to device communication) within a system, particularly those intended for use at the point-of-care, and how this role information is communicated. In addition, it describes the importance of clinical scenarios in creating device models for interoperable devices.

View Article and Find Full Text PDF

Medical device and health information technology systems are increasingly interdependent with users demanding increased interoperability. Related safety standards must be developed taking into account these systems' perspective. In this article, we describe the current development of medical device standards and the need for these standards to address medical device informatics.

View Article and Find Full Text PDF

In this article, we describe the role of "clinical scenario" information to assure the safety of interoperable systems, as well as the system's ability to deliver the requisite clinical functionality to improve clinical care. Described are methods and rationale for capturing the clinical needs, workflow, hazards, and device interactions in the clinical environment. Key user (clinician and clinical engineer) needs and system requirements can be derived from this information, therefore, improving the communication from clinicians to medical device and information technology system developers.

View Article and Find Full Text PDF

Kekulé first suggested a hexagonal structure for benzene in 1865. For over a half-century after, chemists struggled to reconcile proposed structures for benzene and other aromatic compounds with their resistance to chemical transformation and tendency to maintain the type during reaction. The combined structural and reactivity features of these compounds were eventually covered by the term 'aromaticity'.

View Article and Find Full Text PDF

The ability to identify the functional correlates of structural and sequence variation in proteins is a critical capability. We related structures of influenza A N10 and N11 proteins that have no established function to structures of proteins with known function by identifying spatially conserved atoms. We identified atoms with common distributed spatial occupancy in PDB structures of N10 protein, N11 protein, an influenza A neuraminidase, an influenza B neuraminidase, and a bacterial neuraminidase.

View Article and Find Full Text PDF

Strigolactones (SLs) are plant hormones and regulators of root development, including lateral root (LR) formation, root hair (RH) elongation and meristem cell number, in a MORE AXILLARY GROWTH 2 (MAX2)-dependent way. However, whether SL signaling is acting cell-autonomously or in a non-cell-autonomous way in roots is unclear. We analyzed root phenotype, hormonal responses and gene expression in multiple lines of Arabidopsis thaliana max2-1 mutants expressing MAX2 under various tissue-specific promoters and shy2 mutants.

View Article and Find Full Text PDF

In recent years, there has been an increase in the popularity of light-emitting diode (LED)-based, battery-powered transilluminators (BPTs) for facilitating transdermal vascular access in adults and neonates. BPTs are believed to have lower potential for inducing skin burns than prior devices based on high-power broadband lamps; however, the optical and thermal outputs of BPTs are not well documented and safety limits for these devices are not well established. In this study, we characterize and assess the optical and thermal outputs of six BPTs that incorporate red, orange and white LEDs.

View Article and Find Full Text PDF