Publications by authors named "Weinberg P"

Purpose: The patchy anatomical distribution of atherosclerosis has been attributed to variation in haemodynamic wall shear stress (WSS). The consensus is that low WSS and a high Oscillatory Shear Index (OSI) trigger the disease. We found that atherosclerosis at aortic branch sites correlates threefold better with transverse WSS (transWSS), a metric which quantifies multidirectional near-wall flow.

View Article and Find Full Text PDF

Ultrasound imaging is a valuable clinical tool. It is commonly achieved using the delay and sum beamformer algorithm, which takes the signals received by an array of sensors and generates an image estimating the spatial distribution of the signal sources. This algorithm, while computationally efficient, has limited resolution and suffers from high side lobes.

View Article and Find Full Text PDF

Objective: Super-resolution ultrasound (SRUS) imaging through localizing and tracking microbubbles, also known as ultrasound localization microscopy (ULM), can produce sub-diffraction resolution images of micro-vessels. We have recently demonstrated 3-D selective SRUS with a matrix array and phase change contrast agents (PCCAs). However, this method is limited to a small field of view (FOV) and by the complex hardware required.

View Article and Find Full Text PDF

This study investigated the sensitivity and specificity of identifying heart failure with reduced ejection fraction (HFrEF) from measurements of the intensity and timing of arterial pulse waves. Previously validated methods combining ultrafast B-mode ultrasound, plane-wave transmission, singular value decomposition (SVD), and speckle tracking were used to characterize the compression and decompression ("S" and "D") waves occurring in early and late systole, respectively, in the carotid arteries of outpatients with left ventricular ejection fraction (LVEF) < 40%, determined by echocardiography, and signs and symptoms of heart failure, or with LVEF ≥ 50% and no signs or symptoms of heart failure. On average, the HFrEF group had significantly reduced S-wave intensity and energy, a greater interval between the R wave of the ECG and the S wave, a reduced interval between the S and D waves, and an increase in the S-wave shift (SWS), a novel metric that characterizes the shift in timing of the S wave away from the R wave of the ECG and toward the D wave (all < 0.

View Article and Find Full Text PDF

Objective: This study aimed to realise 3-D super-resolution ultrasound imaging transcutaneously with a row-column array which has far fewer independent electronic channels and a wider field of view than typical fully addressed 2-D matrix arrays. The in vivo image quality of the row-column array is generally poor, particularly when imaging non-invasively. This study aimed to develop a suite of image formation and post-processing methods to improve image quality and demonstrate the feasibility of ultrasound localisation microscopy using a row-column array, transcutaneously on a rabbit model and in a human.

View Article and Find Full Text PDF

Objective: The aim of this study is to demonstrate 3-dimensional (3D) acoustic wave sparsely activated localization microscopy (AWSALM) of microvascular flow in vivo using phase change contrast agents (PCCAs).

Materials And Methods: Three-dimensional AWSALM using acoustically activable PCCAs was evaluated on a crossed tube microflow phantom, the kidney of New Zealand White rabbits, and the brain of C57BL/6J mice through intact skull. A mixture of C 3 F 8 and C 4 F 10 low-boiling-point fluorocarbon gas was used to generate PCCAs with an appropriate activation pressure.

View Article and Find Full Text PDF

Effects of mechanical stress on the permeability of vascular endothelium are important to normal physiology and in the development of atherosclerosis. Here we elucidate novel effects using commercially available and modified hollow-fibre bioreactors, in which endothelial cells form confluent monolayers lining plastic capillaries with porous walls, contained in a cartridge. The capillaries were perfused with a near-aortic waveform, and permeability was assessed by the movement of rhodamine-labelled albumin from the intracapillary to the extracapillary space.

View Article and Find Full Text PDF

Background: Chronic respiratory diseases (CRDs) may cause reduced oxygen availability to organs and body tissues, leading to an increased risk for ischemic damage, which can result in brain tissue injury. This damage can lead to a myriad of neurological symptoms contributing to cognitive decline. Cognitive interventions may attenuate cognitive deficits in people with CRDs; however, the effects have not yet been systematically summarized in the literature.

View Article and Find Full Text PDF
Article Synopsis
  • Super-resolution ultrasound imaging (SRUS) helps visualize microvascular structures and flow at a higher resolution than traditional methods, but standard techniques struggle with closely packed microbubbles in 3D.
  • This study introduces a new fast 3D coherence beamformer and adapts existing 2D beamformers for 3D use, improving imaging techniques.
  • Results show that these new adaptive beamformers effectively reduce noise and enhance image quality, with the variance-based method demonstrating the best performance, thereby improving SRUS's potential in biomedical applications.
View Article and Find Full Text PDF

Multidirectional or disturbed flow promotes endothelial dysfunction and is associated with early atherogenesis. Here we investigated the role of Wnt signalling in flow-mediated endothelial dysfunction. The expression of Frizzled-4 was higher in cultured human aortic endothelial cells (ECs) exposed to disturbed flow compared to that seen for undisturbed flow, obtained using an orbital shaker.

View Article and Find Full Text PDF

Effects of hemodynamic shear stress on endothelial cells have been extensively investigated using the "swirling well" method, in which cells are cultured in dishes or multiwell plates placed on an orbital shaker. A wave rotates around the well, producing complex patterns of shear. The method allows chronic exposure to flow with high throughput at low cost but has two disadvantages: a number of shear stress characteristics change in a broadly similar way from the center to the edge of the well, and cells at one location in the well may release mediators into the medium that affect the behavior of cells at other locations, exposed to different shears.

View Article and Find Full Text PDF

Calcific aortic valve disease affects the aortic side of the valve, exposed to low magnitude multidirectional ("disturbed) blood flow, more than it affects the ventricular side, exposed to high magnitude uniaxial flow. Overt disease is preceded by endothelial dysfunction and inflammation. Here we investigate the potential role of the transforming growth factor-β (TGF-β) receptor ALK5 in this process.

View Article and Find Full Text PDF

Perfusion by the microcirculation is key to the development, maintenance and pathology of tissue. Its measurement with high spatiotemporal resolution is consequently valuable but remains a challenge in deep tissue. Ultrasound Localization Microscopy (ULM) provides very high spatiotemporal resolution but the use of microbubbles requires low contrast agent concentrations, a long acquisition time, and gives little control over the spatial and temporal distribution of the microbubbles.

View Article and Find Full Text PDF

Complex patterns of hemodynamic wall shear stress occur in regions of arterial branching and curvature. Areas within these regions can be highly susceptible to atherosclerosis. Although many studies have characterized the response of vascular endothelial cells to shear stress in a categorical manner, our study herein addresses the need of characterizing endothelial behaviors over a continuous range of shear stress conditions that reflect the extensive variations seen in the vasculature.

View Article and Find Full Text PDF

Arterial pulse waves contain clinically useful information about cardiac performance, arterial stiffness and vessel tone. Here we describe a novel method for non-invasively assessing wave properties, based on measuring changes in blood flow velocity and arterial wall diameter during the cardiac cycle. Velocity and diameter were determined by tracking speckles in successive B-mode images acquired with an ultrafast scanner and plane-wave transmission.

View Article and Find Full Text PDF

The patchy distribution of atherosclerosis within the arterial system is consistent with a controlling influence of hemodynamic wall shear stress (WSS). Patterns of low, oscillatory and transverse WSS have been invoked to explain the distribution of disease in the aorta. Disease of coronary arteries has greater clinical importance but blood flow in these vessels may be complicated by their movement during the cardiac cycle.

View Article and Find Full Text PDF

Haemodynamic wall shear stress varies from site to site within the arterial system and is thought to cause local variation in endothelial permeability to macromolecules. Our aim was to investigate mechanisms underlying the changes in paracellular permeability caused by different patterns of shear stress in long-term culture. We used the swirling well system and a substrate-binding tracer that permits visualisation of transport at the cellular level.

View Article and Find Full Text PDF

Many studies of cardiovascular function require a realistic representation of vascular geometry. Corrosion casting has been used to acquire such geometries for many decades. However, the fidelity with which this method reproduces vascular anatomy has not been completely determined.

View Article and Find Full Text PDF

A striking feature of atherosclerosis is its patchy distribution within the vascular system; certain arteries and certain locations within each artery are preferentially affected. Identifying the local risk factors underlying this phenomenon may lead to new therapeutic strategies. The large variation in lesion prevalence in areas of curvature and branching has motivated a search for haemodynamic triggers, particular those related to wall shear stress (WSS).

View Article and Find Full Text PDF

Heart failure is treatable, but in the United Kingdom, the 1-, 5- and 10-year mortality rates are 24.1, 54.5 and 75.

View Article and Find Full Text PDF

Blood flow velocity and wall shear stress (WSS) influence and are influenced by vascular disease. Their measurement is consequently useful in the laboratory and clinic. Contrast-enhanced ultrasound image velocimetry (UIV) can estimate them accurately but the need to inject contrast agents limits utility.

View Article and Find Full Text PDF

Effects of fluid dynamics on cells are often studied by growing the cells on the base of cylindrical wells or dishes that are swirled on the horizontal platform of an orbital shaker. The swirling culture medium applies a shear stress to the cells that varies in magnitude and directionality from the center to the edge of the vessel. Computational fluid dynamics methods are used to simulate the flow and hence calculate shear stresses at the base of the well.

View Article and Find Full Text PDF

Atherosclerosis is characterized by focal accumulations of lipid within the arterial wall, thought to arise from effects of hemodynamic wall shear stress (WSS) on endothelial permeability. Identifying pathways that mediate the effects of shear on permeability could therefore provide new therapeutic opportunities. Here, we consider whether the sphingosine-1-phosphate (S1P) pathway could constitute such a route.

View Article and Find Full Text PDF