Power transformer is one of the critical and expensive apparatus in high voltage power system. Hence, using highly efficient gas sensors to real-time monitor the fault characteristic gases dissolved in transformer oil is in pressing need to ensure the smooth functionalization of the power system. Till date, as a semiconductor metal oxide, zinc oxide (ZnO) is considered as the promising resistive-type gas sensing material.
View Article and Find Full Text PDFAcetylene gas (CH) is one of the main arc discharge characteristic gases dissolved in power transformer oil. It is of great potential to monitor the fault gas on-line by applying gas sensor technology. In this paper, gas sensors based on nanorods and nanoneedles assembled hierarchical NiO structures have been prepared.
View Article and Find Full Text PDFGuang Pu Xue Yu Guang Pu Fen Xi
October 2015
Ethane is one of major fault characteristic gases dissolved in power transformer, the detection of Ethane with high accuracy and sensitivity is the key of dissolved gas analysis. In this paper, based on optical feedback theory and cavity-enhanced absorption spectroscopy, combined with quantum cascade laser, a detection system for dissolved gas C2 H6 in transformer oil was built up. Based on the symmetry of the individual cavity modes, the phase matching of returning light in resonance with the cavity was achieved through LabVIEW codes.
View Article and Find Full Text PDF