Publications by authors named "Warren G Campbell"

Purpose: Tumor motion plays a key role in the safe delivery of stereotactic body radiation therapy (SBRT) for pancreatic cancer. The purpose of this study was to use tumor motion measured in patients to establish limits on motion magnitude for safe delivery of pancreatic SBRT and to help guide motion-management decisions in potential dose-escalation scenarios.

Methods And Materials: Using 91 sets of pancreatic tumor motion data, we calculated the motion-convolved dose of the gross tumor volume, duodenum, and stomach for 25 patients with pancreatic cancer.

View Article and Find Full Text PDF

Purpose: Stereotactic body radiation therapy (SBRT) for pancreatic cancer requires a skillful approach to deliver ablative doses to the tumor while limiting dose to the highly sensitive duodenum, stomach, and small bowel. Here, we develop knowledge-based artificial neural network dose models (ANN-DMs) to predict dose distributions that would be approved by experienced physicians.

Methods: Arc-based SBRT treatment plans for 43 pancreatic cancer patients were planned, delivering 30-33 Gy in five fractions.

View Article and Find Full Text PDF

Background And Purpose: Ablative radiation therapy can be beneficial for pancreatic cancer, and motion mitigation helps to reduce dose to nearby organs-at-risk. Here, we compared two competing methods of motion mitigation-abdominal compression and respiratory gating.

Materials And Methods: CBCT scans of 19 pancreatic cancer patients receiving stereotactic body radiation therapy were acquired with and without abdominal compression, and 3D target motion was reconstructed from CBCT projection images.

View Article and Find Full Text PDF

Purpose: Implanted fiducial markers are often used in radiotherapy to facilitate accurate visualization and localization of tumors. Typically, such markers are used to aid daily patient positioning and to verify the target's position during treatment. These markers can also provide a wealth of information regarding tumor motion, yet determining their accurate position in thousands of images is often prohibitive.

View Article and Find Full Text PDF

Purpose: The objective of this work is to demonstrate imaging artifacts that can occur during the optical computed tomography (CT) scanning of polymer gel dosimeters due to radiation-induced refractive index (RI) changes in polyacrylamide gels.

Methods: A 1 L cylindrical polyacrylamide gel dosimeter was irradiated with 3 × 3 cm(2) square beams of 6 MV photons. A prototype fan-beam optical CT scanner was used to image the dosimeter.

View Article and Find Full Text PDF

Purpose: The objective of this work is to introduce a prototype fan-beam optical computed tomography scanner for three-dimensional (3D) radiation dosimetry.

Methods: Two techniques of fan-beam creation were evaluated: a helium-neon laser (HeNe, λ = 543 nm) with line-generating lens, and a laser diode module (LDM, λ = 635 nm) with line-creating head module. Two physical collimator designs were assessed: a single-slot collimator and a multihole collimator.

View Article and Find Full Text PDF