Publications by authors named "Waris T"

Leukemia is found in approximately 2.3 million people worldwide and causes many deaths all over the world. This research study was conducted to figure out the link of single nucleotide polymorphisms of genes CEBPA (rs34529039), NPM1 (rs753788683), IDH1 (of rs11554137) and RUNX1 (rs13051066) polymorphisms as biomarker potential in leukemia patients.

View Article and Find Full Text PDF

In the present study, the commercially available three different fabrics cotton, nylon and cotton/nylon were modified by chitosan and silver nanoparticles using a crosslinker triethyl orthoformate (TEOF). Resulted cotton‑silver (Ag-Cs-Cot), nylon‑silver (Ag-Cs-Nyl) and cotton-nylon silver (Ag-Cs-Cot-Nyl) fabrics showed significant anti-bacterial activity even after 50 washing cycles. Silver nanoparticles were prepared by reducing silver nitrate through sodium borohydride at 0 °C.

View Article and Find Full Text PDF

The prolonged hypoxic conditions hinder chronic wounds from healing and lead to severe conditions such as delayed re-epithelialization and enhanced risk of infection. Multifunctional wound dressings are highly required to address the challenges of chronic wounds. Herein, we report polyurethane-coated sodium per carbonate-loaded chitosan hydrogel (CSPUO ) as a multifunctional dressing.

View Article and Find Full Text PDF

This research on a thyroxine/heparin-based cotton wound dressing tests angiogenic and wound healing ability of thyroxine/heparin in a chick chorionic allantoic membrane bioassay and in skin wounds in healthy rats. Commercially available cotton dressings were simply loaded with thyroxine/heparin solutions and coated with wax. Prior to undertaking the animal study, we assessed in vitro release of thyroxine/heparin from coated and uncoated cotton dressings.

View Article and Find Full Text PDF

The central nervous system (CNS) encompasses the brain and spinal cord and is considered the processing center and the most vital part of human body. The central nervous system (CNS) barriers are crucial interfaces between the CNS and the periphery. Among all these biological barriers, the blood-brain barrier (BBB) strongly impede hurdle for drug transport to brain.

View Article and Find Full Text PDF

The absorption capacity of cotton dressings is a critical factor in their widespread use where they help absorb wound exudate. Cotton wax dressings, in contrast, are used for wounds where care is taken to avoid adhesion of dressings to sensitive wounds such as burn injuries. Accordingly, we explored the loading of 2-deoxy-D-ribose (2dDR), a small sugar, which stimulates angiogenesis and wound healing in normal and diabetic rats, into both types of dressings and measured the release of it over several days.

View Article and Find Full Text PDF

Excessive hemorrhage through any reasons is a life threatening process. Artemisia scoparia of family Asteraceae has been used in local system of medicine to stop bleeding from wounds and in injuries, antiseptic, in healing urticarial and for removal of worms from the body. Aerial parts of A.

View Article and Find Full Text PDF

Transplantation of autologous fat as pedicle or transposition flaps has been a classical method in plastic surgery for tissue reconstruction. The injection of fat for soft tissue reconstruction is also an old innovation. This approach has some significant drawbacks such as resorption of the fat transplant.

View Article and Find Full Text PDF

The aim of this study was to assess tissue reactions to bioabsorbable self-reinforced ciprofloxacin-releasing polylactide/polyglycolide (SR-PLGA) 80/20 screws in rabbits' cranial bone. Two screws were implanted in each rabbit, one screw on either side of the sagittal suture (n = 28 rabbits). Animals were sacrificed after 2, 4, 8, 16, 24, 54 and 72 weeks, four animals per group.

View Article and Find Full Text PDF

Poly-L/D-lactide (PLDLA) 96/4 fibrous implants have been introduced to engineer functional fibrous constructions in situ. The current study was undertaken to evaluate the guidance of the fibrous tissue formation and the tissue reaction of porous PLDLA 96/4 scaffolds implanted in subcutaneous tissue. Three various PLDLA 96/4 knitted-mesh scaffolds (Loose, Ordinary, and Dense) were implanted subcutaneously in 32 rats, and followed-up from 3 days until 48 weeks postsurgery.

View Article and Find Full Text PDF

Background: Common Achilles tendon ruptures are not usually fixed by bioabsorbable sutures due to limitations in their strength retention properties. Modern technology has made it possible to develop bioabsorbable sutures with prolonged strength retention.

Aims: To evaluate histologically tissue reactions of poly-L/D-lactide (PLDLA) sutures implanted in Achilles tendon of rabbits.

View Article and Find Full Text PDF

Purpose: To analyze histologically tissue reactions to bioabsorbable PLA96 in rabbit eyes.

Methods: Scleral buckling operations were carried out in 48 rabbits. Two materials were used: bioabsorbable PLA96 (polylactide 96/4; L/D molar ratio 96/4) and silicone sponge.

View Article and Find Full Text PDF

Antibiotic coating systems have been successfully used to prevent bacterial attachment and biofilm formation. Our purpose was to evaluate whether bioabsorbable polylactide-co-glycolide (PLGA) 80/20 on its own, and PLGA together with ciprofloxacin (PLGA+C) have any advantages over titanium in preventing Staphylococcus epidermidis attachment and biofilm formation in vitro. Cylindrical specimens of titanium, PLGA, and PLGA+C in triplicate were examined for S.

View Article and Find Full Text PDF

Purpose: To measure the amount and duration of indentation depth achieved with biodegradable poly-L/D-lactide 96/4 (PLA96) and silicone sponge implants.

Methods: Thirty rabbits underwent a scleral buckling procedure. A PLA96 buckling implant was used in 15 rabbits and a silicone sponge buckling implant was in 15 rabbits.

View Article and Find Full Text PDF

A novel bioabsorbable composite membrane of polyethylene oxide terephthalate and polybutylene terephthalate copolymer (Polyactive 70/30) combined with bioactive glass No. 13--93 was tested in the repair of experimental maxillary alveolar cleft defects. In this pilot study, the possible ability of the membrane to promote bone formation by guided tissue regeneration was investigated.

View Article and Find Full Text PDF

A self-reinforced bioabsorbable poly-L-lactide/polyglycolide (SR-PLGA) 80/20 screw 2.0 mm in diameter was implanted transphyseally across the distal growth plate of the right femur in 24 immature rabbits. Radiologic evaluation revealed a mean shortening of 3.

View Article and Find Full Text PDF

To investigate the changes in noradrenaline concentrations in transplanted arterial grafts in rats, 31 female rats 4 to 6 weeks old of the AO/Ks:OC strain were operated on. Femoral arterial grafts were anastomosed to carotid arteries and compared with control femoral segments. Six rats were included in each follow-up group at 0, 1, 4, and 12 weeks, and there were seven rats in the 20-week follow-up group.

View Article and Find Full Text PDF

Bioabsorbable osteofixation devices were developed to avoid problems associated with metals. Bioabsorbable devices are mostly made of the polymers polylactide, polyglycolide, and their copolymers [polyglycolide-co-polylactide and P(L/DL)LA]. Using the technique of self-reinforcement of bioabsorbable materials, it is possible to manufacture osteofixation devices with ultra high strength.

View Article and Find Full Text PDF

The aim of this study was to assess tissue reactions to bioabsorbable self-reinforced polylactide/polyglycolide (SR-PLGA) 80/20 miniscrews in rabbit cranial bone. One PLGA screw was implanted on one side and one titanium screw on the other side of the sagittal suture (n = 21). Three animals were sacrificed after 2, 4, 8, 16, 24, 54, and 72 weeks.

View Article and Find Full Text PDF

The aim of this study was to investigate the rate of disappearance of noradrenaline in arterial grafts after their transplanation. Arterial grafts were harvested from AO/Ks:OC strain rats. In each rat, a graft was harvested from the femoral artery and transplanted into the common carotid artery.

View Article and Find Full Text PDF

The practice of using implants is growing day by day, and more foreign materials are being inserted for various indications. The field of implantology thus deserves intensive research and careful evaluation of results. Solutions to overcome current problems and risks are necessary.

View Article and Find Full Text PDF

Several bioabsorbable internal fixation systems are currently in use in the field of bone surgery. To test the mechanical properties of recently developed amorphous self-reinforced poly-L/DL-lactide [SR-P(L/DL)LA] 70/30 tacks in comparison with commercially available SR-P(L/DL)LA 70/30 (BioSorbFX; Bionx Implants Ltd) miniscrews, SR-P(L/DL)LA miniscrews (length = 6.0 mm, core diameter = 1.

View Article and Find Full Text PDF

We report on the feasibility of applying bioabsorbable tacks using a new tack-shooter to fix bioabsorbable plates applied endocranially for the correction of three cases of trigonocephaly. Tacks do not require tapping or tightening because they are applied using a tack-shooter directly into drill holes in the bone. Hence, the technique saves valuable operative time.

View Article and Find Full Text PDF

A new device (a tackshooter) to apply bioabsorbable tacks in craniofacial surgery has been developed. This new device was used in 15 children who underwent various cranioplasty procedures to demonstrate its reliability and simple technical application in cranial bone osteofixation. Bone segments were fixed together and to the cranial bones using Biosorb plates and tacks.

View Article and Find Full Text PDF

This study is one of a series in which the authors evaluate various absorbable sheets to guide bone regeneration in cranial bone defects. The aim was to evaluate the use of self-reinforced poly-L,D-lactide 96/4 (SR-PLA96) sheets for cranial bone tissue engineering in experimental defects in rabbits. Square defects of 10 x 10 mm were created in the right parietal bone.

View Article and Find Full Text PDF