Publications by authors named "Wannapha Nobnop"

Article Synopsis
  • PreciseART is an adaptive radiation therapy software integrated into the Precision treatment planning system that monitors dose variations during cancer treatment.
  • The study compared PreciseART’s automatic dose recalculation with a traditional treatment planning system, finding no significant differences in accuracy for both phantom and patient studies.
  • The notification system of PreciseART effectively alerts users about dose compliance, confirming its usefulness in clinical adaptive radiation therapy.
View Article and Find Full Text PDF
Article Synopsis
  • The study examined the relationship between scalp radiation doses and alopecia in patients undergoing conventional treatment for primary brain tumors.
  • 48 patients were analyzed, revealing that higher radiation doses significantly correlated with both transient and permanent hair loss, with specific thresholds identified for each type of alopecia.
  • The results suggest that the dose to 2% of scalp volume (D2) can serve as a predictive measure for the occurrence and severity of hair loss following radiation therapy.
View Article and Find Full Text PDF

Purpose: This study aims to introduce modified fixed field volumetric modulated arc therapy (MF-VMAT) which manually opened the field size by fixing the jaws and comparing it to the typical planning technique, auto field volumetric modulated arc therapy (AF-VMAT) in cervical cancer treatment planning.

Methods And Materials: Previously treated twenty-eight cervical cancer plans were retrospectively randomly selected and replanned in this study using two different planning techniques: AF-VMAT and MF-VMAT, resulting in a total of fifty-six treatment plans. In this study, we compared both planning techniques in three parts: (1) Organ at Risk (OARs) and whole-body dose, (2) Treatment plan efficiency, and (3) Treatment plan accuracy.

View Article and Find Full Text PDF

Objective: This retrospective study evaluated the preliminary outcomes of image-guided vaginal brachytherapy (IG-VBT) in the adjuvant treatment of high intermediate risk endometrial cancer.

Materials And Methods: Data were collected from 48 patients who underwent adjuvant IG-VBT between 2019 and 2022 at the Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University. The vaginal cuff clinical target volume (CTV-VC) is composed of a 4-mm-thick band around vaginal cylinder at the upper 3 cm of the vaginal cuff.

View Article and Find Full Text PDF

Purpose: This study aimed to report 12 years of experience in the development of a quality assurance system in radiation oncology in a university hospital.

Material And Methods: We developed the Quality Assurance Program in Radiation Oncology (QUAPRO) in 2008 to detect treatment deviation in the radiotherapy (RT) process with three steps of near-miss detection: simulation and prescription (primary check, PC), treatment planning (secondary check, SC), and treatment delivery process (tertiary check, TC). We transferred our paper-based medical records to electronic-based radiotherapy information systems (RTISs) in 2013.

View Article and Find Full Text PDF

The dose expansion methods as the skin flash and virtual bolus were used to solve intrafraction movement for breast planning due to breathing motion. We investigated the skin dose in each planning method by using optically stimulated luminescence on an in-house moving phantom for breast cancer treatment in tomotherapy. The impact of respiratory motion on skin dose between static and dynamic phantom's conditions was evaluated.

View Article and Find Full Text PDF

Purpose: We prospectively investigated the acute toxicities focusing on skin and hematologic function in breast cancer patients who received hypofractionated whole breast irradiation with simultaneous integrated boost (HF-WBI-SIB) with helical tomotherapy (HT), with or without regional nodal irradiation (RNI).

Methods: The dose of WBI and RNI was 42.4 Gy in 16 fractions.

View Article and Find Full Text PDF

The objective of the study is to verify the dose delivered on helical tomotherapy based on treatment plan with varying virtual bolus (VB) thickness. The target was localized on the ArcCHECK image by 3 mm margin from the phantom surface. The dimension of target, which includes the ArcCHECK's detectors, with the 4.

View Article and Find Full Text PDF

Background: With full access to both helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT), we compared locally advanced non-small cell lung cancer (LA-NSCLC) treatment plans and verified the plans using patient-specific pretreatment quality assurance (PSQA).

Materials And Methods: For each of the seventeen patients included in the study, two treatment plans (i.e.

View Article and Find Full Text PDF

Cancer stem cells (CSCs) play a critical role in radiation resistance and recurrence. Thus, drugs targeting CSCs can be combined with radiotherapy to improve its antitumor efficacy. Here, we investigated whether a gallotannin extract from seed (MPSE) and its main bioactive compound, pentagalloyl glucose (PGG), could suppress the stemness trait and further confer the radiosensitivity of head and neck squamous cell carcinoma (HNSCC) cell lines.

View Article and Find Full Text PDF

Background: Left-sided post-mastectomy radiotherapy (PMRT) certainly precedes some radiation dose to the cardiopulmonary organs causing many side effects. To reduce the cardiopulmonary dose, we created a new option of the breathing adapted technique by using abdominal compression applied with a patient in deep inspiration phase utilizing shallow breathing. This study aimed to compare the use of abdominal compression with shallow breathing (ACSB) with the free breathing (FB) technique in the left-sided PMRT.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate retrospectively the treatment results when using various image-guided adaptive brachytherapy treatments for cervical cancer treated by radical radiotherapy.

Methods And Materials: From 2014 to 2017, 188 patients with cervical carcinoma were treated by whole pelvic radiotherapy plus four fractions of image-guided brachytherapy. Eight patients were excluded because of missing data.

View Article and Find Full Text PDF

Purpose: To compare dose to the targets and organs at risk (OARs) in different situations for postmastectomy patients who require radiation to the chest wall with or without regional nodal irradiation when using three treatment techniques.

Methods And Materials: Thirty postmastectomy radiotherapy (PMRT) patients previously treated by helical tomotherapy (HT) at our institution were identified for the study. The treatment targets were classified in three situations which consisted of, the chest wall (CW) only, the chest wall plus supraclavicular lymph nodes (CW + SPC), and the chest wall plus supraclavicular and whole axillary lymph nodes irradiation (CW + SPC+AXLN).

View Article and Find Full Text PDF

Background: Most of the patients who have been treated by post-mastectomy radiotherapy (PMRT) experience skin toxicity. There have been few studies on acute radiation dermatitis in breast cancer patients who received hypofractionation PMRT.

Methods: 62 patients were randomized to receive a general skin care regimen with or without the addition of an emulsion of olive oil and calcium hydroxide twice a day, from the initiation of PMRT to 2 weeks after radiotherapy.

View Article and Find Full Text PDF

Objective: We evaluated the long-term outcomes and late toxicity of conventional fractionated (CF) and hypofractionated (HF) postmastectomy radiotherapy (PMRT) in terms of locoregional recurrence-free survival (LRRFS), disease-free survival (DFS), overall survival (OS), and late toxicity.

Methods: A cohort of 1640 of breast cancer patients receiving PMRT between January 2004 and December 2014 were enrolled. Nine hundred eighty patients were treated with HF-PMRT: 2.

View Article and Find Full Text PDF

Introduction: The registration accuracy of megavoltage computed tomography images is limited by low image contrast when compared to that of kilovoltage computed tomography images. Such issues may degrade the deformable image registration accuracy. This study evaluates the deformable image registration from kilovoltage to megavoltage images when using different deformation methods and assessing nasopharyngeal carcinoma patient images.

View Article and Find Full Text PDF

We present a single center's experience of treatment outcomes and dosimetric parameters for breast cancer patients treated with hypofractionated Helical TomoTherapy (HT). This is a retrospective study of one hundred and thirty-six patients with invasive breast cancer treated between March 2012 and October 2016. Dosimetric parameters and 3-year loco-regional failure free survival (LRFFS) were analyzed.

View Article and Find Full Text PDF

Introduction: Deformable image registration (DIR) is used to modify structures according to anatomical changes for observing the dosimetric effect. In this study, megavoltage computed tomography (MVCT) images were used to generate cumulative doses for nasopharyngeal cancer (NPC) patients by various DIR methods. The performance of the multiple DIR methods was analysed, and the impact of dose accumulation was assessed.

View Article and Find Full Text PDF

Background: The aim of the study was to analyse of two-year loco-regional failure free survival (LRFFS), distant metastasis free survival (DMFS), overall survival (OS), and toxicity outcomes of the first 100 nasopharyngeal carcinoma patients in Thailand treated by helical tomotherapy.

Patients And Methods: Between March 2012 and December 2015, 100 patients with non-metastatic nasopharyngeal carcinoma were treated by helical tomotherapy. All patients were treated by platinum-based concurrent chemoradiotherapy and adjuvant or neo-adjuvant chemotherapy.

View Article and Find Full Text PDF

Introduction: The application of deformable image registration (DIR) to megavoltage computed tomography (MVCT) images benefits adaptive radiotherapy. This study aims to quantify the accuracy of DIR for MVCT images when using different deformation methods assessed in a cubic phantom and nasopharyngeal carcinoma (NPC) patients.

Methods: In the control studies, the DIR accuracy in air-tissue and tissue-tissue interface areas was observed using twelve shapes of acrylic and tissue-equivalent material inserted in the phantom.

View Article and Find Full Text PDF

Objective: To evaluate the outcomes of image-guided brachytherapy combined with 3D conformal or intensity modulated external beam radiotherapy (3D CRT/IMRT) in cervical cancer at Chiang Mai University.

Methods: From 2008 to 2011, forty-seven patients with locally advanced cervical cancer were enrolled in this study. All patients received high-technology (3D CRT/IMRT) whole pelvic radiotherapy with a total dose of 45-46 Gy plus image-guided High-Dose-Rate intracavitary brachytherapy 6.

View Article and Find Full Text PDF