Publications by authors named "Wanita Howard"

Background: Epic Beaker Clinical Pathology (CP) is a relatively new laboratory information system (LIS) operating within the Epic suite of software applications. To date, there have not been any publications describing implementation of Beaker CP. In this report, we describe our experience in implementing Beaker CP version 2012 at a state academic medical center with a go-live of August 2014 and a subsequent upgrade to Beaker version 2014 in May 2015.

View Article and Find Full Text PDF

Background. The occurrence of community-associated infections due to extended-spectrum β-lactamase (ESBL)-producing Escherichia coli has been recognized as a major clinical problem in Europe and other regions. Methods.

View Article and Find Full Text PDF

The Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) instruments were evaluated for the identification of nonfermenting gram-negative bacilli (NFGNB) by a blinded comparison to conventional biochemical or molecular methods. Two hundred NFGNB that were recovered from cultures from cystic fibrosis patients in the University of Iowa Health Care (UIHC) Microbiology Laboratory between 1 January 2006 and 31 October 2010 were sent to Mayo Clinic for analysis with the Bruker Biotyper (software version 3.0) and to bioMérieux for testing with Vitek MS (SARAMIS database version 3.

View Article and Find Full Text PDF

Methicillin-susceptible Staphylococcus aureus (MSSA) isolates lacking mecA yet testing positive on the Xpert MRSA assay were recovered from culture for 7.7% of 248 Xpert-positive nasal samples. These "false-positive" Xpert results may be attributed to staphylococcal cassette chromosome (SCC) elements without the mecA gene.

View Article and Find Full Text PDF

The BD Phoenix AP instrument reduced the manual setup time for the Phoenix system by 50%. For batches of 14 organisms, the average manual manipulation time per isolate was 89.5 s for BD Phoenix by the use of the AP instrument and 101 s for Vitek 2 (P<0.

View Article and Find Full Text PDF

This multicenter study evaluated the BD Phoenix Automated Microbiology System STREP panel (BD Diagnostic Systems). Antimicrobial susceptibility testing (AST) with 13 agents was performed on 2,013 streptococci (938 Streptococcus pneumoniae isolates; 396 group B streptococci [GBS]; 369 viridans group streptococci [VGS]; 290 beta-hemolytic streptococcus groups A, C, and G; and 20 other streptococci) with the Phoenix system and a broth microdilution reference method. Clinical and challenge isolates were tested against cefepime, cefotaxime (CTX), ceftriaxone (CTR), clindamycin (CLI), erythromycin (ERY), gatifloxacin, levofloxacin, linezolid, meropenem, penicillin (PEN), tetracycline (TET), trimethoprim-sulfamethoxazole, and vancomycin.

View Article and Find Full Text PDF

Active surveillance for methicillin-resistant Staphylococcus aureus (MRSA) is among the strategies recommended by the Society for Healthcare Epidemiology of America for control of nosocomial MRSA infections. Infection control and laboratory personnel desire rapid, sensitive, and inexpensive methods to enhance surveillance activities. A multicenter study was performed to evaluate a new selective and differential chromogenic medium, BBL CHROMagar MRSA (C-MRSA) medium (BD Diagnostics, Sparks, MD), which enables recovery and concomitant identification of MRSA strains directly from nasal swab specimens taken from the anterior nares.

View Article and Find Full Text PDF