A novel zero-liquid discharge (ZLD) technology for desulfurization wastewater treatment is put forward in this paper. A ZLD reconstruction project performed on 2 × 320 MW desulfurization system was taken as the research object, to study the evaporator structure and the key factors affecting spray evaporation through CFD numerical simulation. The result shows that when the evaporator diameter is 2.
View Article and Find Full Text PDF