Background: To compare the diagnostic accuracy and predictive value of aneurysm sac volume measurement versus maximum diameter measurement of abdominal aortic aneurysm sac after endovascular aneurysm repair (EVAR) in patients with type II endoleak.
Patients And Methods: Retrospective study on a cohort of 103 patients who presented with a type II endoleak after EVAR for infrarenal abdominal aortic aneurysm. Maximum diameter and volumetric measurements were calculated on computed tomography follow-up scans at 3 months and 1 year after index surgery.
Hybrid depth electrodes are increasingly being used for epilepsy monitoring and human neurophysiology research. Microwires extending from the tip of the Behnke-Fried (BF) electrode into (sub)cortical areas allow to isolate single neurons and perform microstimulation. Conventional CT or MRI visualize the entire microwire bundle as an artifact extending from the BF electrode tip with low resolution, without proper identification of individual microwires.
View Article and Find Full Text PDFHR-pQCT has become standard practice when quantifying volumetric BMD (vBMD) in vivo. Yet, it is only accessible to peripheral sites, with small fields of view and lengthy scanning times. This limits general applicability in clinical workflows.
View Article and Find Full Text PDFBackground: Our aim was to analyse abdominal aneurysm sac thrombus density and volume on computed tomography (CT) after endovascular aneurysm repair (EVAR).
Methods: Patients who underwent EVAR between January 2005 and December 2010 and had at least four follow-up CT exams available over the first five years of follow-up were included in this retrospective single-centre study. Thrombus density and aneurysm sac volume were calculated on unenhanced CT scans.
J Med Imaging (Bellingham)
May 2024
Purpose: The objective of this study is to evaluate the accuracy of an augmented reality (AR) system in improving guidance, accuracy, and visualization during the subxiphoidal approach for epicardial ablation.
Approach: An AR application was developed to project real-time needle trajectories and patient-specific 3D organs using the Hololens 2. Additionally, needle tracking was implemented to offer real-time feedback to the operator, facilitating needle navigation.
Background: The complex anatomical structure of the foot-ankle imposes challenges to accurately quantify detailed hindfoot kinematics and estimate musculoskeletal loading parameters. Most systems used to capture or estimate dynamic joint function oversimplify the anatomical structure by reducing its complexity.
Research Question: Can four dimensional computed tomography (4D CT) imaging in combination with an innovative foot manipulator capture in vivo hindfoot kinematics during a simulated stance phase of walking and can talocrural and subtalar articular joint mechanics be estimated based on a detailed in silico musculoskeletal foot-ankle model.
Background: Vascular disrupting agents (VDAs) are known to specifically target preexisting tumoural vasculature. However, systemic side effects as safety or toxicity issues have been reported from clinical trials, which call for further preclinical investigations. The purpose is to gain insights into their non-specific off-targeting effects on normal vasculature and provide clues for exploring underlying molecular mechanisms.
View Article and Find Full Text PDFVisualization and quantification of bone microarchitecture in the human knee allows gaining insight into normal bone structure, and into the structural changes occurring in the onset and progression of bone diseases such as osteoporosis and osteoarthritis. However, current imaging modalities have limitations in capturing the intricacies of bone microarchitecture. Photon counting computed tomography (PCCT) is a promising imaging modality that presents high-resolution three-dimensional visualization of bone with a large field of view.
View Article and Find Full Text PDFConforming to the current replace-reduce-refine 3Rs' guidelines in animal experiments, a series of explorative efforts have been made to set up operable biomedical imaging-guided platforms for qualitative and quantitative evaluations on pharmacological effects of tumor vascular-disrupting agents (VDAs), based on the chick embryos (CEs) with its chorioallantoic membrane (CAM), in this overview. The techniques and platforms have been hierarchically elaborated, from macroscopic to microscopic and from overall to specific aspects. A protocol of LED lamplight associated with a new deep-learning algorithm was consolidated to screen out weak CEs by using the CAM vasculature imaging.
View Article and Find Full Text PDFBackground: Previous studies have shown that patients with giant cell arteritis (GCA) who have vascular F-fluorodeoxyglucose (FDG) uptake at diagnosis are at increased risk for thoracic aortic complications.
Objective: To measure the association between vascular FDG uptake at diagnosis and the change in aortic dimensions.
Design: Prospective cohort study.
Am J Physiol Lung Cell Mol Physiol
November 2023
Objectives: To compare clinical image quality and perceived impact on diagnostic interpretation of chest CT findings between ultra-high-resolution photon-counting CT (UHR-PCCT) and conventional high-resolution energy-integrating-detector CT (HR-EIDCT) using visual grading analysis (VGA) scores.
Materials And Methods: Fifty patients who underwent a UHR-PCCT (matrix 512 × 512, 768 × 768, or 1024 × 1024; FOV average 275 × 376 mm, 120 × 0.2 mm; focal spot size 0.
Driven by a global trend of applying replace-reduce-refine or 3Rs' guidance for experimental animals in life sciences, chick embryo and particularly allantois with its chorioallantoic membrane have been increasingly utilized to substitute laboratory animals, which call for more extensive and updated knowledge about this novel experimental setup. In this study, being noninvasive, nonionizing, and super-contrasting with high spatiotemporal resolutions, magnetic resonance imaging (MRI) was chosen as an imaging modality for in ovo monitoring morphologic evolution of the chick embryo, allantois, and chorioallantoic membrane longitudinally throughout embryonic day (ED) 1 until ED20. Cooled in 0°C ice bath for 60 min to reduce MRI motion artifacts, 3 chick embryos (n = 60 in total) on each ED were scanned by a clinical 3.
View Article and Find Full Text PDFObjective: Our study was a prospective in vivo study performed on an animal model to evaluate the safety and performance of a novel venous stent designed specifically for venous applications.
Methods: The novel stents were implanted in the inferior vena cava of nine sheep. The stents were deployed with different distances between the closed cell rings to test for if the segments might migrate after being deployed at maximal distance.
Background And Aims: Polycystic liver disease (PLD) can lead to extensive hepatomegaly. Symptom relief is the primary goal of the treatment. The role of the recently developed disease-specific questionnaires for identification of the thresholds and the assessment of therapy needs further investigation.
View Article and Find Full Text PDFPhoton-counting computed tomography (PCCT) is an innovative technological advancement in relation to x-ray detectors which offers ultra-high-resolution images. The current study aimed to evaluate the visualization ability of PCCT compared to cone-beam computed tomographic (CBCT) devices for challenging endodontic diagnostic tasks. A reference image of an anthropomorphic phantom was acquired using an industrial micro-CT device.
View Article and Find Full Text PDFObjectives: Polycystic liver disease (PLD) is characterized by growth of hepatic cysts, causing hepatomegaly. Disease severity is determined using total liver volume (TLV), which can be measured from computed tomography (CT). The gold standard is manual segmentation which is time-consuming and requires expert knowledge of the anatomy.
View Article and Find Full Text PDFAmong various anti-cancer therapies, tumor vascular disrupting agents (VDAs) play a crucial role, for which their off-targeting effects on normal vessels need also to be investigated. The purpose of this study was to set up an in-ovo platform that combines a laser speckle contrast imaging (LSCI) modality with chick embryo chorioallantoic membrane (CAM) to real-time monitor vascular diameters and perfusion without and with intravascular injection. Two eggshell windows for both observation or measurement and injection were opened.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
April 2022
To characterize computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) pneumonia and their value in outcome prediction.Chest CTs of 182 patients with a confirmed diagnosis of COVID-19 infection by real-time reverse transcription polymerase chain reaction were evaluated for the presence of CT-abnormalities and their frequency. Regarding the patient outcome each patient was categorized in 5 progressive stages and the duration of hospitalization was determined.
View Article and Find Full Text PDFObjectives: To determine the accuracy of scoutless, fixed-dose ultra-low-dose (ULD) CT compared to standard-dose (SD) CT for pulmonary nodule detection and semi-automated nodule measurement, across different patient sizes.
Methods: Sixty-three patients underwent ULD and SD CT. Two readers examined all studies visually and with computer-aided detection (CAD).
Purpose: Selective internal radiation therapy (SIRT) requires a good liver registration of multi-modality images to obtain precise dose prediction and measurement. This study investigated the feasibility of liver registration of CT and MR images, guided by segmentation of the liver and its landmarks. The influence of the resulting lesion registration on dose estimation was evaluated.
View Article and Find Full Text PDFIntroduction: Programmable shunt valve settings can sometimes be difficult to assess using classic read-out tools, warranting a skull X-ray.
Research Question: Can we use available head computed tomography (CT) scans to determine the valve settings, in order to obviate the need for additional skull X-rays?
Material And Methods: The valve setting of two different programmable shunts (Codman Certas Plus® and Sophysa Polaris®) were assessed by two blinded observers in 24 patients using 65 head CT scans (slice thickness ≤2 mm). Using multi-planar reconstruction (MPR) tools, images were resliced according to the direction of the valve, allowing a direct readout of the valve settings.