Publications by authors named "Wajeeh Saadi"

Advanced cell culture methods for modeling organ-level structure have been demonstrated to replicate in vivo conditions more accurately than traditional in vitro cell culture. Given that the liver is particularly important to human health, several advanced culture methods have been developed to experiment with liver disease states, including infection with Plasmodium parasites, the causative agent of malaria. These models have demonstrated that intrahepatic parasites require functionally stable hepatocytes to thrive and robust characterization of the parasite populations' response to investigational therapies is dependent on high-content and high-resolution imaging (HC/RI).

View Article and Find Full Text PDF

While many advanced liver models support hepatic phenotypes necessary for drug and disease studies, these models are characterized by intricate features such as co-culture with one of more supporting cell types or advanced media perfusion systems. These systems have helped elucidate some of the critical biophysical features missing from standard well-plate based hepatocyte culture, but their advanced designs add to their complexity. Additionally, regardless of the culture system, primary hepatocyte culture systems suffer from reproducibility issues due to phenotypic variation and expensive, limited supplies of donor lots.

View Article and Find Full Text PDF

The fabrication and operation of a gradient-generating microfluidic device for studying cellular behavior is described. A microfluidic platform is an enabling experimental tool, because it can precisely manipulate fluid flows, enable high-throughput experiments, and generate stable soluble concentration gradients. Compared to conventional gradient generators, poly(dimethylsiloxane) (PDMS)-based microfluidic devices can generate stable concentration gradients of growth factors with well-defined profiles.

View Article and Find Full Text PDF

The chemokine receptor CXCR4 and its ligand CXCL12 play an important role in breast cancer invasion and metastasis, and induce the chemotaxis of various types of cancer cells. Previous studies of CXCL12-induced chemotaxis have, for the most part, relied on endpoint assays (e.g.

View Article and Find Full Text PDF

We have developed a simple microfluidic device for generating stable concentration gradients in 2D and 3D environments. The device, termed the Ladder Chamber, uses a two-compartment diffusion system to generate steady state gradients across flow-free channels that connect the source and sink channels. To demonstrate the utility of the Ladder Chamber for cell migration, neutrophil chemotaxis was successfully observed in soluble chemoattractant (IL-8) gradient.

View Article and Find Full Text PDF

Growth factor-induced chemotaxis of cancer cells is believed to play a critical role in metastasis, directing the spread of cancer from the primary tumor to secondary sites in the body. Understanding the mechanistic and quantitative behavior of cancer cell migration in growth factor gradients would greatly help in future treatment of metastatic cancers. Using a novel microfluidic chemotaxis chamber capable of simultaneously generating multiple growth factor gradients, we examined the migration of the human metastatic breast cancer cell line MDA-MB-231 in various conditions.

View Article and Find Full Text PDF

Neutrophils migrating in tissue respond to complex overlapping signals generated by a variety of chemotactic factors (CFs). Previous studies suggested a hierarchy between bacteria-derived CFs and host-derived CFs but could not differentiate neutrophil response to potentially equal host-derived CFs (IL-8 and LTB4). This paper reports neutrophil migration in conflicting gradients of IL-8 and LTB4 using a microfluidic chemotaxis device that can generate stable and well-defined gradients.

View Article and Find Full Text PDF

Chemotaxis, directed cell migration in a gradient of chemoattractant, is an important biological phenomenon that plays pivotal roles in cancer metastasis. Newly developed microfluidic chemotaxis chambers (MCC) were used to study chemotaxis of metastatic breast cancer cells, MDA-MB-231, in EGF gradients of well-defined profiles. Migration behaviors of MDA-MB-231 cells in uniform concentrations of EGF (0, 25, 50, and 100 ng/ml) and EGF (0-25, 0-50, and 0-100 ng/ml) with linear and nonlinear polynomial profiles were investigated.

View Article and Find Full Text PDF

Neutrophils need to correctly interpret gradients of chemotactic factors (CFs) such as interleukin 8 (IL-8) to migrate to the site of infection and perform immune functions. Because diffusion-based chemotaxis assays used in previous studies suffer from temporally changing gradients, it is difficult to distinguish the influence of CF gradient steepness from mean CF concentration on chemotaxis. To better understand the roles of mean CF concentration and CF gradient steepness, we developed a microfluidic device that can maintain stable IL-8 gradients.

View Article and Find Full Text PDF

This paper describes a microfluidic approach to generate dynamic temporal and spatial concentration gradients using a single microfluidic device. Compared to a previously described method that produced a single fixed gradient shape for each device, this approach combines a simple "mixer module" with gradient generating network to control and manipulate a number of different gradient shapes. The gradient profile is determined by the configuration of fluidic inputs as well as the design of microchannel network.

View Article and Find Full Text PDF