Background: This study compared the performance of a single blood draw of high-sensitivity troponin T (hsTnT), high-sensitivity troponin I (hsTnI) and conventional troponin I (cTnI) within a modified HEART score for predicting 30-day MACE at Emergency Department (ED) presentation, and established local reference norms for all three assays by determining the cut-off point which yielded the highest sensitivity and negative predictive value for acute myocardial infarction and 30-day MACE.
Methods: This single-center prospective cohort study recruited chest pain patients at the ED, whose hsTnT, hsTnI and cTnI were taken on admission. Subjects were classified into low and non-low risk group according to their modified HEART score, with MACE as the primary endpoint.
J Clin Pathol
April 2019
Clinical laboratories for in vitro diagnostics are facing pressure to preserve cost control while providing better services through new initiatives. Laboratory automation is a partial answer to this problem, having come a long way from the early days of clinical laboratory testing. The journey and implementation of automation in the Singapore General Hospital's Clinical Biochemistry Laboratory has allowed for sustained performance in the light of increasing workload and service commitments amid an evolving healthcare environment.
View Article and Find Full Text PDFClot activator serum tubes have significantly improved turnaround times for result reporting compared to plain tubes. With increasing workload and service performance expectations confronting clinical laboratories with high-volume testing and with particular emphasis on critical analytes, attention has focussed on preanalytical variables that can be improved. We carried out a field study on the test performance of BD vacutainer rapid serum tubes (RSTs) compared to current institutional issued BD vacutainer serum separator tubes (SSTs) in its test result comparability, clotting time, and stability on serum storage.
View Article and Find Full Text PDFBackground: Maltose interference is a concern with blood glucose testing at point-of-care. We evaluated a maltose interference-free test strip (with a modified recombinant glucose dehydrogenase-pyrroloquinoline quinone system) for the Accu-Chek(®) Performa glucose meter (Roche Diagnostics, Mannheim, Germany).
Methods: Blood specimens (n = 120) sent for clinical laboratory glucose testing were used in assessing performance characteristics, including imprecision, linearity, clinical impact analysis, and method comparison, of the test strips.
Background And Aim: We have evaluated procalcitonin (PCT) as a diagnostic marker for bacterial gastroenteritis (GE) and as a disease activity marker in inflammatory bowel disease (IBD) patients.
Methods: This was a prospective single-center study performed over a 1-year period. Venous blood samples were drawn from hospitalized patients with acute GE and tested for PCT, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and total white cell count (TWC); stools from the same patients were tested for standard pathogens.
Diabetes Res Clin Pract
September 2002