Publications by authors named "Wagter C"

Article Synopsis
  • Visual navigation is crucial for autonomous robots, but its heavy computational and memory demands limit its use in small, resource-constrained robots like drones.
  • The authors propose an insect-inspired navigation strategy that compresses panoramic images and their spatial relationships, allowing robots to efficiently store and recall their paths using minimal resources.
  • A proof of concept using a 56-gram drone showed it could successfully navigate routes up to 100 meters with minimal data storage (under 20 bytes per meter), paving the way for broader applications of tiny autonomous robots.
View Article and Find Full Text PDF

This Review discusses the main results obtained in training end-to-end neural architectures for guidance and control of interplanetary transfers, planetary landings, and close-proximity operations, highlighting the successful learning of optimality principles by the underlying neural models. Spacecraft and drones aimed at exploring our solar system are designed to operate in conditions where the smart use of onboard resources is vital to the success or failure of the mission. Sensorimotor actions are thus often derived from high-level, quantifiable, optimality principles assigned to each task, using consolidated tools in optimal control theory.

View Article and Find Full Text PDF

Background: Prostate cancer patients treated with radiotherapy are susceptible to acute gastrointestinal (GI) toxicity due to substantial overlap of the intestines with the radiation volume. Due to their intimate relationship with GI toxicity, faecal microbiome and metabolome dynamics during radiotherapy were investigated.

Material & Methods: This prospective study included 50 prostate cancer patients treated with prostate (bed) only radiotherapy (PBRT) (n = 28) or whole pelvis radiotherapy (WPRT) (n = 22) (NCT04638049).

View Article and Find Full Text PDF

In radiology, low X-ray energies (<140 keV) are used to obtain an optimal image while in radiotherapy, higher X-ray energies (MeV) are used to eradicate tumor tissue. In radiation research, both these X-ray energies being used to extrapolate research to clinical practice. However, the energy deposition of X-rays depends on their energy spectrum, which might lead to changes in biological response.

View Article and Find Full Text PDF

Proton therapy is of great interest to pediatric cancer patients because of its optimal depth dose distribution. In view of healthy tissue damage and the increased risk of secondary cancers, we investigated DNA damage induction and repair of radiosensitive hematopoietic stem and progenitor cells (HSPCs) exposed to therapeutic proton and photon irradiation due to their role in radiation-induced leukemia. Human CD34 HSPCs were exposed to 6 MV X-rays, mid- and distal spread-out Bragg peak (SOBP) protons at doses ranging from 0.

View Article and Find Full Text PDF

Background: The currently available treatment planning systems (TPSs) are neither designed nor intended for accurate dose calculations in nontarget regions. The aim of this work is to quantify the accuracy and reliability of nontarget doses calculated by a commercially available TPS.

Methods: Nontarget doses calculated by the collapsed cone (CC) (v5.

View Article and Find Full Text PDF

Attitude control is an essential flight capability. Whereas flying robots commonly rely on accelerometers for estimating attitude, flying insects lack an unambiguous sense of gravity. Despite the established role of several sense organs in attitude stabilization, the dependence of flying insects on an internal gravity direction estimate remains unclear.

View Article and Find Full Text PDF

Purpose: This work presents the clinical validation of RayStation's electron Monte Carlo code by the use of diodes and plane parallel radiation detectors in homogenous and heterogeneous tissues. Results are evaluated against internationally accepted criteria.

Methods: The Monte Carlo-based electron beam dose calculation code was validated using diodes, air- and liquid-filled parallel radiation detectors on an Elekta linac with beam energies of 4, 6, 8, 10, and 12 MeV.

View Article and Find Full Text PDF

Natural fliers utilize passive and active flight control strategies to cope with windy conditions. This capability makes them incredibly agile and resistant to wind gusts. Here, we study how insects achieve this, by combining Computational Fluid Dynamics (CFD) analyses of flying fruit flies with freely-flying robotic experiments.

View Article and Find Full Text PDF

Background: We investigated how radiotherapy (RT) parameters may contribute to the risk of lymphopenia in urological tumors and we discussed how this may impact clinical outcomes.

Material & Methods: A systematic review was performed according to the preferred reporting items for systematic reviews and meta-analysis (PRISMA) guidelines. The PubMed, Embase and ISI Web Of Knowledge databases were searched.

View Article and Find Full Text PDF

Background: This study aimed to verify the dosimetric impact of Acuros XB (AXB) (AXB, Varian Medical Systems Palo Alto CA, USA), a two model-based algorithm, in comparison with Anisotropic Analytical Algorithm (AAA ) calculations for prostate, head and neck and lung cancer treatment by volumetric modulated arc therapy (VMAT ), without primary modification to AA. At present, the well-known and validated AA algorithm is clinically used in our department for VMAT treatments of different pathologies. AXB could replace it without extra measurements.

View Article and Find Full Text PDF

This work presents a review and discussion of the challenges that must be solved in order to successfully develop swarms of Micro Air Vehicles (MAVs) for real world operations. From the discussion, we extract constraints and links that relate the local level MAV capabilities to the global operations of the swarm. These should be taken into account when designing swarm behaviors in order to maximize the utility of the group.

View Article and Find Full Text PDF

Swarms of tiny flying robots hold great potential for exploring unknown, indoor environments. Their small size allows them to move in narrow spaces, and their light weight makes them safe for operating around humans. Until now, this task has been out of reach due to the lack of adequate navigation strategies.

View Article and Find Full Text PDF

Background And Purpose: The prognostic value of radiomics for non-small cell lung cancer (NSCLC) patients has been investigated for images acquired prior to treatment, but no prognostic model has been developed that includes the change of radiomic features during treatment. Therefore, the aim of this study was to investigate the potential added prognostic value of a longitudinal radiomics approach using cone-beam computed tomography (CBCT) for NSCLC patients.

Materials And Methods: This retrospective study includes a training dataset of 141 stage I-IV NSCLC patients and three external validation datasets of 94, 61 and 41 patients, all treated with curative intended (chemo)radiotherapy.

View Article and Find Full Text PDF

Insects are among the most agile natural flyers. Hypotheses on their flight control cannot always be validated by experiments with animals or tethered robots. To this end, we developed a programmable and agile autonomous free-flying robot controlled through bio-inspired motion changes of its flapping wings.

View Article and Find Full Text PDF

Purpose: Automated planning aims to speed up treatment planning and improve plan quality. We compared manual planning with automated planning for lung stereotactic body radiation therapy based on dose-volume histogram statistics and clinical preference.

Methods And Materials: Manual and automated intensity modulated radiation therapy plans were generated for 56 patients by use of software developed in-house and Pinnacle 9.

View Article and Find Full Text PDF

Purpose: To assess the dosimetric impact of a patient positioning device for prone breast radiotherapy and assess the accuracy of a treatment planning system (TPS) in predicting this impact.

Methods: Beam attenuation and build-up dose perturbations, quantified by ionization chamber and radiochromic film dosimetry, were evaluated for 3 components of the patient positioning device: the carbon fiber baseplate, the support cushions and the support wedge for the contralateral breast. Dose calculations were performed using the XVMC dose engine implemented in the Monaco TPS.

View Article and Find Full Text PDF

This study evaluated absorbed dose measurements in the build-up region of conventional (FF) versus flattening filter-free (FFF) photon beams. The absorbed dose in the build-up region of static 6 and 10MV FF and FFF beams was measured using radiochromic film and extrapolation chamber dosimetry for single beams with a variety of field sizes, shapes and positions relative to the central axis. Removing the flattening filter generally resulted in slightly higher relative build-up doses.

View Article and Find Full Text PDF

Radiotherapy is a mainstay in the postoperative treatment of breast cancer as it reduces the risks of local recurrence and mortality after both conservative surgery and mastectomy. Despite recent efforts to decrease irradiation volumes through accelerated partial irradiation techniques, late cardiac and pulmonary toxicity still occurs after breast irradiation. The importance of this pulmonary injury towards lung metastasis is unclear.

View Article and Find Full Text PDF

An accurate knowledge of the unsteady aerodynamic forces acting on a bio-inspired, flapping-wing micro air vehicle (FWMAV) is crucial in the design development and optimization cycle. Two different types of experimental approaches are often used: determination of forces from position data obtained from external optical tracking during free flight, or direct measurements of forces by attaching the FWMAV to a force transducer in a wind-tunnel. This study compares the quality of the forces obtained from both methods as applied to a 17.

View Article and Find Full Text PDF

Purpose: To report the dosimetric results and impact of volumetric arc therapy (VMAT) on temporary alopecia and hair-loss related quality of life (QOL) in whole brain radiotherapy (WBRT).

Methods: The potential of VMAT-WBRT to reduce the dose to the hair follicles was assessed. A human cadaver was treated with both VMAT-WBRT and conventional opposed field (OF) WBRT, while the subcutaneously absorbed dose was measured by radiochromic films and calculated by the planning system.

View Article and Find Full Text PDF

Background And Purpose: Cone-beam computerized tomography (CBCT) enables three-dimensional information of the scanned region and provides soft tissue images with good spatial resolution. Our aim was to optimize image acquisition settings for prone and supine breast radiotherapy with respect to contour accuracy, clinical practicalities, and radiation dose.

Patients And Methods: CBCT images were acquired for both prone and supine anthropomorphic phantoms and a female cadaver in supine and prone set-up.

View Article and Find Full Text PDF

Background And Purpose: Extracellular matrix (ECM) reorganization critically contributes to breast cancer (BC) progression and radiotherapy response. We investigated the molecular background and functional consequences of collagen type I (col-I) reorganization by irradiated breast cancer cells (BCC).

Materials And Methods: Radiation-induced (RI) col-I reorganization was evaluated for MCF-7/6, MCF-7/AZ, T47D and SK-BR-3 BCC.

View Article and Find Full Text PDF

Previously, we described the radiation-induced (RI) 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) effect as the increased MTT metabolization at the intermediate dose region after the irradiation of an MCF-7/6 cell monolayer with an X-ray dose gradient. We wondered if the cell monolayer at the intermediate dose region was characterized by an increased metabolic activity. In this study, we unraveled the mechanisms behind the RI MTT effect.

View Article and Find Full Text PDF

The radiochromic film, which is used, in combination with a flatbed scanner has become a widely used tool for a quantitative evaluation of radiation dose in radiation therapy. One aspect of uncertainty using the radiochromic film is the magnitude of orientation effects when the orientation of the film is not kept constant during the digitization process. The aim of this note was to investigate the impact of using a combination of two crossed sheets of EBT2 film on various aspects of radiochromic film dosimetry.

View Article and Find Full Text PDF