Unlabelled: A new generation of planetary rover instruments, such as PIXL (Planetary Instrument for X-ray Lithochemistry) and SHERLOC (Scanning Habitable Environments with Raman Luminescence for Organics and Chemicals) selected for the Mars 2020 mission rover payload, aim to map mineralogical and elemental composition in situ at microscopic scales. These instruments will produce large spectral cubes with thousands of channels acquired over thousands of spatial locations, a large potential science yield limited mainly by the time required to acquire a measurement after placement. A secondary bottleneck also faces mission planners after downlink; analysts must interpret the complex data products quickly to inform tactical planning for the next command cycle.
View Article and Find Full Text PDFHibernomas are rare neoplasms originating in brown adipose tissue of humans and other animal species, including laboratory animals. Background incidence values for these tumors in all common strains of laboratory rats are generally accepted as being <0.1%.
View Article and Find Full Text PDFWe demonstrate apertureless near-field microscopy of single molecules at sub-10 nm resolution. With a novel phase filter, near-field images of single organic fluorophores were obtained with approximately sixfold improvement in the signal-to-noise ratio. The improvement allowed pairs of molecules separated by approximately 15 nm to be reliably and repeatedly resolved, thus demonstrating the first true Rayleigh resolution test for near-field images of single molecules.
View Article and Find Full Text PDFBirth Defects Res B Dev Reprod Toxicol
February 2006
Background: This study was conducted to evaluate the potential adverse effects of ethylbenzene (EB) on reproductive capability from whole-body inhalation exposure of F0 and F1 parental animals.
Methods: Four groups of Crl:CD(SD)IGS BR rats (30/sex/group for F0 and 25/sex/group for F1) were exposed to 0, 25, 100, and 500 ppm EB for 6 hr/day for at least 70 consecutive days before mating. Inhalation exposure for the F0 and F1 females continued throughout mating, gestation through gestation day (GD) 20, and lactation days (LD) 5-21.
We demonstrate unambiguously that the field enhancement near the apex of a laser-illuminated silicon tip decays according to a power law that is moderated by a single parameter characterizing the tip sharpness. Oscillating the probe in intermittent contact with a semiconductor nanocrystal strongly modulates the fluorescence excitation rate, providing robust optical contrast and enabling excellent background rejection. Laterally encoded demodulation yields images with <10 nm spatial resolution, consistent with independent measurements of tip sharpness.
View Article and Find Full Text PDF