Publications by authors named "WC Jennings"

We performed chlorine inactivation experiments for Elizabethkingia anophelis and E. meningoseptica bacterial strains from clinical and environmental sources. Free chlorine concentration × contact time values <0.

View Article and Find Full Text PDF
Article Synopsis
  • The concept of "venous outflow stenosis" is better understood as "inflow-outflow imbalance," where the outflow capacity of arteriovenous (AV) access can't adequately handle the blood inflow volume (Qa) without increased pressure.
  • This imbalance leads to higher outflow resistance and intraluminal pressure, causing various clinical issues that impact patient health.
  • The authors suggest that assessing access flow is crucial for treatment planning, advocating for a dual treatment strategy of angioplasty for low or normal Qa cases and flow reduction for those with excessive Qa.
View Article and Find Full Text PDF

Background: The Guatemalan Foundation for Children with Kidney Diseases collaborated with Bridge of Life, a not-for-profit charitable organization, to establish a vascular access program. We reviewed our experience with graded surgical responsibility and structured didactic training, creating arteriovenous fistulas (AVF) for Guatemalan children.

Methods: Pediatric vascular access missions were completed from 2015 to 2023 and analyzed retrospectively.

View Article and Find Full Text PDF

Objective: End-stage renal disease (ESRD) in childhood and adolescence is rare, with relatively few published reports of pediatric ESRD vascular access. This study analyzes a 10-year experience creating arteriovenous fistulas (AVFs) in children and adolescents. Our goal is to review our strategy for creating functional autogenous vascular access in younger patients and report our results.

View Article and Find Full Text PDF

Human norovirus (HuNoV) is an important cause of acute gastroenteritis and can be transmitted by water exposures, but its persistence in water is not well understood. Loss of HuNoV infectivity in surface water was compared with persistence of intact HuNoV capsids and genome segments. Surface water from a freshwater creek was filter-sterilized, inoculated with HuNoV (GII.

View Article and Find Full Text PDF

Functioning vascular access is an essential element for life-saving hemodialysis therapy. A surgically-created arteriovenous fistula has been considered the best option for many years. Recently, two manufacturers developed systems for percutaneous/endovascular creation of an arteriovenous fistula (WavelinQ and Ellipsys).

View Article and Find Full Text PDF

Purpose: To report the 5-year results from the Pivotal Multicenter Trial of Ultrasound-Guided Percutaneous Arteriovenous Fistula (pAVF) Creation for Hemodialysis Access.

Materials And Methods: The retrospective review of 107 intent-to-treat (ITT) patients from the pivotal trial provided a long-term follow-up population (LTP) of 85 patients with a median follow-up duration of 50 months (range, 12-60 months). Data evaluated in the LTP group were fistula maturation and usage, secondary procedures, and complications.

View Article and Find Full Text PDF

We performed a single-center retrospective study of prospectively collected data for all patients who had flow reduction surgery with FRAME FR between November 2020 and January 2021. Ten patients had arteriovenous fistula flow reduction surgery with this technique. One patient had a distal fistula, whereas nine were within the cubital fossa.

View Article and Find Full Text PDF

The first percutaneous systems used to create an arteriovenous fistula for hemodialysis were approved by the US Food and Drug Administration in 2018 and included the Ellipsys and WavelinQ devices. Early results and longer-term studies of these catheter-based devices suggest that they offer important benefits and potentially improved outcomes in patients with appropriate anatomy. The deep communicating vein in the cubital fossa and its relationship to the proximal radial artery or proximal ulnar artery are key vascular elements of both systems.

View Article and Find Full Text PDF

Wastewater surveillance, the measurement of pathogen levels in wastewater, is used to evaluate community-level infection trends, augment traditional surveillance that leverages clinical tests and services (e.g., case reporting), and monitor public health interventions (1).

View Article and Find Full Text PDF

Mitochondrial structure and organization is integral to maintaining mitochondrial homeostasis and an emerging biological target in aging, inflammation, neurodegeneration, and cancer. The study of mitochondrial structure and its functional implications remains challenging in part because of the lack of available tools for direct engagement, particularly in a disease setting. Here, we report a gold-based approach to perturb mitochondrial structure in cancer cells.

View Article and Find Full Text PDF

Background: Establishing a forearm arteriovenous fistula (AVF) offers preferred cannulation sites and preserves proximal access opportunities. When a radiocephalic AVF at the wrist is not feasible and the upper arm cephalic and median cubital veins are inadequate, an AV graft or more complex access procedure is often required. Creating a retrograde flow forearm AVF (RF-AVF) is a valuable alternative where the mid-forearm median antebrachial or cephalic vein is adequate, offering forearm cannulation zones with AVF outflow through deep and superficial collaterals.

View Article and Find Full Text PDF

Brachiocephalic arteriovenous fistulas (AVF) makeup approximately one third of prevalent dialysis vascular accesses. The most common cause of malfunction with this access is cephalic arch stenosis (CAS). The accepted requirement for treatment of a venous stenosis lesion is ⩾50% stenosis associated with hemodynamically abnormalities.

View Article and Find Full Text PDF

Human norovirus (hNoV) is an important etiology of gastrointestinal illness and can be transmitted via ingestion of contaminated water. Currently impractical to culture, hNoV detection is reliant on real-time polymerase chain reaction (RT-PCR)-based methods. This approach cannot distinguish between infective and inactivated viruses because intact regions of the RNA genome can amplify even if the damage is present in other regions of the genome or because intact genetic material is not contained within an infectious virion.

View Article and Find Full Text PDF

Rationale & Objective: Percutaneous arteriovenous fistulas (AVF) are created by establishing a proximal forearm anastomosis and offer a safe and reliable vascular access. This study compares the Ellipsys percutaneous AVF with a proximal forearm Gracz-type surgical AVF, chosen for comparison as it is constructed at the same anatomical site.

Study Design: Retrospective study of prospectively collected clinical data.

View Article and Find Full Text PDF

Objective: The aim of the present study was to compare the results between percutaneous arteriovenous fistulas (p-AVFs) created with the Ellipsys device (Ellipsys Vascular Access System; Avenu Medical, San Juan Capistrano, Calif) and surgical arteriovenous fistulas (s-AVFs).

Methods: A single-center retrospective comparative study of the first 107 patients who had undergone p-AVF creation with the Ellipsys system from May 2017 to May 2018 with an equal number of consecutive patients who had undergone s-AVF creation in our center during the same period. The primary endpoints included the maturation and patency rates.

View Article and Find Full Text PDF

Anthropogenic fecal pollution in urban waterbodies can promote the spread of waterborne disease. The objective of this study was to test crAssphage, a novel viral human fecal marker not previously applied for fecal source tracking in Latin America, as a fecal pollution marker in an urban river in Chile. Human fecal markers crAssphage CPQ_064 and HF183, the human pathogen norovirus GII, and culturable fecal indicator bacteria (FIB) were quantified at six locations spanning reaches of the Mapocho River from upstream to downstream of Santiago, as well as in repeated sub-daily frequency samples at two urban locations.

View Article and Find Full Text PDF

Background: Stent placement in the cannulation zone of AVF is becoming alarmingly frequent and sometimes in cases where surgical management would be more appropriate. When complications arise repair can be particularly challenging. We present our experience and management of this problem.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare the clinical outcomes of Ellipsys with those of WavelinQ-4F percutaneous arteriovenous fistulae (pAVF) devices in a single center by a single operator.

Materials And Methods: A retrospective review was conducted in 100 patients who underwent pAVFs procedures (65 Ellipsys and 35 WavelinQ patients) and created between December 2017 and December 2019. A total of 69% were male and 37% were diabetic.

View Article and Find Full Text PDF

Timely creation and maintenance of a safe and reliable vascular access is essential for hemodialysis patients with end-stage renal disease. Hemodialysis access-induced distal ischemia (HAIDI) is a recognized complication of arteriovenous fistulas and grafts that may result in serious or even devastating consequences. Avoiding such complications is clearly preferred over treatment of HAIDI once established.

View Article and Find Full Text PDF

Objective: We evaluate the creation of a percutaneous proximal radial artery-radial vein arteriovenous fistula with Ellipsys instead of the usual first-stage brachial artery fistula prior to a second-stage brachial vein elevation, in patients with inadequate cephalic and basilic veins.

Methods: Single center study of eight patients (six males, mean = 54 years) who underwent a two-stage brachial vein elevation procedure between May 2017 and October 2019. Inclusion criteria were life expectancy > 6 months, patent brachial and proximal radial artery (>2 mm in diameter) absent/inadequate cephalic and basilic veins, existence of a brachial vein >3 mm in diameter, and in continuity with a proximal radial vein > 2 mm in diameter.

View Article and Find Full Text PDF

Background: The first arteriovenous fistulas were created at the wrist more than 60 years ago. Basic surgical construction techniques remain unchanged with mobilization and repositioning of the vessels followed by a sutured anastomosis. We used the Ellipsys device to construct percutaneous radiocephalic-arteriovenous fistulas at the wrist and report the results.

View Article and Find Full Text PDF