Purpose: To assess objective reading performance at intermediate and near distances using the Salzberg Reading Desk (SRD) (SRD Vision) in patients with cataract who underwent the implantation of a diffractive extended depth of focus intraocular lens (EDOF IOL) in the dominant eye and a hybrid multifocal EDOF IOL in the non-dominant eye.
Methods: This prospective, non-comparative, interventional study included 46 eyes of 23 patients with cataract who underwent bilateral cataract surgery with implantation of the DFR00V Tecnis Synergy IOL (Johnson & Johnson Surgical Vision) in the non-dominant eye and the DXR00V Tecnis Symfony OptiBlue IOL (Johnson & Johnson Surgical Vision) in the dominant eye. At postoperative 6 months, the Salzburg Reading Desk was used to assess distance-corrected reading performance at near and intermediate distances.
Purpose: To compare scanning-slit retinoscopy automated refraction spherical equivalent (ARSE) to subjective manifest refraction spherical equivalent (MRSE) in normal eyes with four different types of intraocular lenses (IOLs).
Design: Retrospective cross-sectional study.
Methods: A total of 279 pseudophakic eyes that underwent lens extraction at a private center with implantation of either a wavefront shaped IOL (Acrysof® Vivity, DFT015), a nonapodized diffractive trifocal IOL (Acrysof® Panoptix), or a monofocal IOL with negative spherical aberration (Tecnis ZCBOO) or aberration-free (Envista Mx60E).
Purpose: To evaluate the prediction of postoperative anatomical lens position (ALP) using intraoperative spectral-domain optical coherence tomography (SD-OCT) lens anatomy metrics in patients who underwent femtosecond laser-assisted cataract surgery.
Methods: Intraoperative SD-OCT (Catalys; Johnson & Johnson Vision) and postoperative optical biometry (IOLMaster 700; Carl Zeiss Meditec AG) were used to assess anterior segment landmarks, including lens thickness, lens volume, anterior chamber depth, lens meridian position (LMP), and measured ALP. LMP was defined as the distance from the corneal epithelium to the lens equator, and ALP was defined as the distance from the corneal epithelium to the IOL surface.
Purpose: To compare the refractive predictability of intraoperative aberrometry (IA, ORA, Alcon) and Barrett True-K/Universal II formulas for intraocular lens (IOL) power calculations in post-corneal refractive surgery and normal eyes.
Methods: Retrospective study of normal and post-corneal refractive surgery eyes that underwent cataract surgery with IA at tertiary academic center. Preoperatively, IOL power calculations were performed using Barrett Universal II (normal eyes) or Barrett True-K (post-corneal refractive surgery eyes) formulas.
Graefes Arch Clin Exp Ophthalmol
July 2021
Objective: To compare the measurement of central thickness and depth of involvement of opacity-bearing corneas at different intensities (mild, moderate, and dense) using different instruments: Visante and Optovue OCTs, ultrasound biomicroscopy (UBM), and ultrasound pachymetry (central thickness).
Methods: Sample of 102 eyes: 70 eyes (68.63 %) with corneal opacity; 32 eyes (31.