Pathophysiologic parameters of the functional neovasculature and the blood-brain barrier of 9L-glioma in rat brain were measured noninvasively by dynamic 1H magnetic resonance imaging studies of gadolinium (Gd)-DTPA uptake. Changes of apparent [Gd-DTPA] uptake in time (CT[t]) were analyzed in a slice through the center of 10 9L-gliomas using fast T1 measurements. The distribution of the contrast agent was spatially correlated with the distribution of perfused microvessels as determined by immunohistochemical analysis.
View Article and Find Full Text PDFFor the in vivo relaxivity of Gd-DTPA at 6.3 T in rat muscle a value of 2.7+/-0.
View Article and Find Full Text PDFGeneral expressions are presented to calculate the maximum likelihood (ML) estimator and corresponding Fisher matrix for Rician-distributed data sets. This estimator results in the most precise, unbiased estimations of T1 from magnitude data sets, even when low signal-to-noise ratios (<6) are present. By optimizing the sample point distributions for inversion-recovery experiments, a 32% increase in precision of the estimated T1 is obtained, compared with a linear sampling scheme.
View Article and Find Full Text PDFThe difference between the experimental and theoretical spatial response function (SRF) of a narrow tube with water is used for a localization test for magnetic resonance spectroscopic imaging (MRSI). From this difference a quantitative performance parameter is derived for the relative amount of signal within a limited region in the field of view. The total signal loss by the MRSI experiment and eddy currents is described by a parameter SL derived from the signal intensities of two echoes.
View Article and Find Full Text PDFBy utilizing achievements and results of two previous concerted research projects on magnetic resonance imaging and spectroscopy (MRS), the EU BIOMED 1 Concerted Action on "Cancer and brain disease characterization and therapy assessment by quantitative MRS" was specifically aimed at: 1) developing at a multicentre level harmonized methodologies and protocols for quantitative and reproducible MRS measurements, as a basis for validating these procedures in well controlled clinical and experimental conditions; and 2) providing multicentre critical reviews on the present understanding of the significance of MRS parameters as possible new markers of diagnosis, prognosis and response to therapy. The programme comprised the following main areas of collaborative research and multicentre evaluation: a) development of methods and protocols for quality assessment, calibration and absolute metabolite quantification in in vivo localized, volume-selective MRS; b) design and validation of a new method for assessing localization performance in spectroscopic imaging (MRSI); c) interlaboratory comparison of different methods of signal processing and data analysis, for improving signal quantification in vivo and in vitro MRS spectra; d) quality assessment of high resolution MRS analyses of biological fluids; e) protocol for assembling a pilot data base of MR spectra of tumour extracts for pattern recognition analysis; f) multicentre review on evaluation of the significance of MRS parameters in monitoring lipid metabolism and function in cancer; and g) multicentre review on evaluation of drug pharmacokinetics and metabolism using MRS. The main results and conclusions of four multi-centre trials on items (a), (b) and (c), which involved 24 teams, are reported in the accompanying papers of this series.
View Article and Find Full Text PDF