Purpose: To evaluate the impact of a versatile flexible ceiling-mounted C-arm on active table and gantry repositioning during interventions and its effect on operator discomfort, system usability, and patient safety compared with a traditional ceiling-mounted system.
Materials And Methods: There were 100 IR procedures studied: 50 in a traditional IR system (standard group) and 50 with a novel multiaxis ceiling-mounted system (test group). FlexArm was capable of multiple gantry rotation points allowing increased access to the patient in addition to 236 cm of lateral x-ray detector travel.
The developments in Computed Tomography (CT) and Magnetic Resonance allow visualization of blood flow in vivo using these techniques. However, validation tests are needed to determine a gold standard. For the validation tests, controllable systems that can generate pulsatile flow are needed.
View Article and Find Full Text PDFTo investigate the relationship between dynamic changes of coronary artery geometry and coronary artery disease (CAD) using computed tomography (CT). Seventy-one patients underwent coronary CT angiography with retrospective electrocardiographic gating. End-systolic (ES) and end-diastolic (ED) phases were automatically determined by dedicated software.
View Article and Find Full Text PDFBackground: Current developments showed a fast-increasing implementation and use of three-dimensional (3D) printing in medical applications. Our aim was to review the literature regarding the application of 3D printing to cardiac valve disease.
Methods: A PubMed search for publications in English with the terms "3D printing" AND "cardiac valve", performed in January 2018, resulted in 64 items.
Eur Heart J Cardiovasc Imaging
December 2015
Accurate annular sizing in transcatheter aortic valve implantation (TAVI) planning is essential. It is now widely recognized that the annulus is an oval structure in most patients, but it remains unclear if the annulus undergoes change in size and shape during the cardiac cycle that may impact prosthesis size selection. Our aim was to assess whether the aortic annulus undergoes dynamic conformational change during the cardiac cycle and to evaluate possible implications for prosthesis size selection.
View Article and Find Full Text PDFLumen contrast-enhancement influences non-calcified atherosclerotic plaque Hounsfield-unit (HU) values in computed tomography (CT). This study aimed to construct and validate an algorithm to correct for this influence. Three coronary vessel phantoms with 1, 2, and 4 mm circular hollow lumina; with normal and plaque-infested walls were scanned simultaneously in oil using a dual-source CT scanner.
View Article and Find Full Text PDF