Publications by authors named "Volkan Bulut"

Introduction: We aimed to evaluate the efficacy of the duration of prophylactic antibiotic administration in patients undergoing transrectal ultrasound (TRUS) guided biopsy.

Material And Methods: A total of 367 patients undergoing a prostate biopsy between September 2007 and June 2009 was reviewed retrospectively and divided into 2 groups according to prophilaxy: oral ciprofloxacin (750 mg every 12 hours) for 3 or more days in Group-1 and single day in Group-2. Demographic characteristics of patients, symptoms, PSA values, IPSS scores, prostate sizes, pathologic results and complications were compared between the groups.

View Article and Find Full Text PDF

A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)-diethyldithiocarbamate-(Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc.

View Article and Find Full Text PDF

Purpose: Cisplatin-based chemotherapy is widely used in the treatment for germ cell testicular tumors. However, long-term complications of this treatment have gained importance, and hypercholesterolemia is one of these. In some studies, hypercholesterolemia is reported following the cisplatin-based chemotherapy.

View Article and Find Full Text PDF

Cloud-point extraction (CPE) using the non-ionic surfactant Triton X-100 was used successfully to remove a highly toxic dye, rhodamine 6G (R6G), from water and wastewater. The effects of different analytical parameters such as pH, concentration of Triton X-100 (TX-100) and salts, equilibrium temperature, and incubation time on the efficiency of the extraction of R6G were studied in detail, and optimum conditions for dye extraction were obtained. Thermodynamic parameters including changes in Gibbs free energy, enthalpy, and entropy were also calculated, and these parameters indicated that the CPE of R6G was feasible, spontaneous, and endothermic in the temperature range of 75-95 degrees C.

View Article and Find Full Text PDF

The TOC in surface waters and wastewater is an important analytical parameter describing the total content of all organic substances containing carbon. In practice, the TOC originated from natural and anthropogenic sources, and even if it is not directly responsible for dangers on human health, its determination is important for any kind of water that is used by public. The aim of this study was to determine variation of total organic carbon (TOC) and total carbon (TC) content in the stream Harsit, which courses in Eastern Black Sea Region, Turkey.

View Article and Find Full Text PDF

A separation-preconcentration procedure was developed for the determination of trace amounts of aluminium in water samples and dialysis concentrates by UV-vis Spectrophotometry after coprecipitation using 8-hydroxyquinoline (8-HQ) as a chelating agent and Co(II) as a carrier element. This procedure is based on filtration of the solution containing precipitate on a cellulose nitrate membrane filter following aluminium(III) coprecipitation with Co/8-HQ and then the precipitates together with membrane filter were dissolved in concentrated nitric acid. The metal contents of the final solution were determined by UV-vis Spectrophotometry with Erio Chrome Cyanine-R standard method.

View Article and Find Full Text PDF

A coprecipitation method has been established for speciation of chromium(III) and chromium(VI) in real samples. The procedure is based on the coprecipitation of Cr(III), by using a new organic coprecipitant, 3-phenyl-4-o-hydroxybenzyl-idenamino-4,5-dihydro-1,2,4-triazole-5-one, without adding any carrier element. After reduction of Cr(VI) by concentrated H2SO4 and ethanol, the method was applied to the determination of total Cr.

View Article and Find Full Text PDF

The present study was carried out to assess the ability of original waste mud (o-WM) and different types of activated waste mud which are acid-activated (a-WM) and precipitated waste mud (p-WM), in order to remove excess of fluoride from aqueous solution by using batch technique. The p-WM exhibited greater performance than the others. Adsorption studies were conducted as a function of pH, contact time, initial fluoride concentration, adsorbent concentration, temperature, etc.

View Article and Find Full Text PDF

A separation/preconcentration procedure, based on the coprecipitation of Cr(3+), Fe(3+), Pb(2+) and Zn(2+) ions using a new organic coprecipitant, 3-phenly-4-o-hydroxybenzylidenamino-4,5-dihydro-1,2,4-triazole-5-one (POHBAT) without adding any carrier element has been developed. The method, thus, has been called carrier element-free coprecipitation (CEFC). The resultant concentrated elements were determined by flame atomic absorption spectrometric determinations.

View Article and Find Full Text PDF

A new, simple, rapid and sensitive separation, preconcentration and speciation procedure for chromium in environmental liquid and solid samples has been established. The present speciation procedure for Cr(III) and Cr(VI) is based on combination of carrier element-free coprecipitation (CEFC) and flame atomic absorption spectrometric (FAAS) determinations. In this method a newly synthesized organic coprecipitant, 5-chloro-3-[4-(trifluoromethoxy) phenylimino]indolin-2-one (CFMEPI), was used without adding any carrier element for coprecipitation of chromium(III).

View Article and Find Full Text PDF

A new co-precipitation method was developed to separate and pre-concentrate Fe(3+), Cu(2+), Cr(3+), Zn(2+), and Pb(2+) ions using an organic co-precipitant, 3-benzyl-4-p-nitrobenzylidenamino-4,5-dihydro-1,2,4-triazole-5-on (BPNBAT) without adding any carrier element, following flame atomic absorption spectrometric (FAAS) determinations. Effect of some analytical conditions, such as pH of the solution, quantity of the co-precipitant, standing time, centrifugation rate and time, sample volume, and interference of concomitant ions were investigated over the recovery yields of the metal ions. The recoveries of the analyte ions were in the range of 95-102%.

View Article and Find Full Text PDF

A simple and accurate method was developed for separation and enrichment of trace levels of gold in environmental samples. The method is based on the adsorption of Au(III)-diethyldithiocarbamate complex on Amberlite XAD-2000 resin prior to the analysis of gold by flame atomic absorption spectrometry after elution with 1 molL(-1) HNO3 in acetone. Some parameters including nitric acid concentration, eluent type, matrix ions, sample volume, sample flow rate and adsorption capacity were investigated on the recovery of gold(III).

View Article and Find Full Text PDF

A new method using a column packed with Amberlite XAD-2010 resin as a solid-phase extractant has been developed for the multi-element preconcentration of Mn(II), Co(II), Ni(II), Cu(II), Cd(II), and Pb(II) ions based on their complex formation with the sodium diethyldithiocarbamate (Na-DDTC) prior to flame atomic absorption spectrometric (FAAS) determinations. Metal complexes sorbed on the resin were eluted by 1 mol L(-1) HNO3 in acetone. Effects of the analytical conditions over the preconcentration yields of the metal ions, such as pH, quantity of Na-DDTC, eluent type, sample volume and flow rate, foreign ions etc.

View Article and Find Full Text PDF

A method for the preconcentration of some transition elements at trace level was proposed using a column filled with Amberlite XAD-2000 resin. Metal ions were adsorbed on XAD-2000 as their diethyldithiocarbamate chelates, then analytes retained on the resin were eluted by 1 mol L(-1) nitric acid in acetone and determined by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters including pH of sample solution, ligand amount, the type, concentration and volume of elution solution, flow rates of the sample and eluent solutions, adsorption capacity of the resin and sample volume on the preconcentration efficiency have been investigated.

View Article and Find Full Text PDF