Measurements of iron complexes and iron stores in the body are crucial for evaluation and management of chelation therapy targeted against iron accumulation or overload in blood and organs. In this work, blood and tissue samples from one normal and one thalassaemic laboratory mouse were studied using Fe Mössbauer spectroscopy at 78 K for the first time. In contrast to human patients, these laboratory mice did not receive any medical treatment, thus the iron components present in the samples are not altered from their natural state.