Two-thirds of out-of-hospital cardiac arrest patients, who survive to hospital admission, die in the hospital from neurological injuries related to cerebral hypoperfusion. Therefore, noninvasive real-time monitoring of the cerebral oxygen metabolism in cardiac arrest patients is extremely important. Hyperspectral near-infrared spectroscopy (hNIRS) is a noninvasive technique that measures concentrations of the key chromophores in the brain, such as oxygenated hemoglobin, deoxygenated hemoglobin, and cytochrome C oxidase (CCO), an intracellular marker of oxygen consumption.
View Article and Find Full Text PDFObjectives: Epinephrine is routinely administered to sudden cardiac arrest patients during resuscitation, but the neurologic effects on patients treated with epinephrine are not well understood. This study aims to assess the cerebral oxygenation and metabolism during ventricular fibrillation cardiac arrest, cardiopulmonary resuscitation, and epinephrine administration.
Design: To investigate the effects of equal dosages of IV epinephrine administrated following sudden cardiac arrest as a continuous infusion or successive boluses during cardiopulmonary resuscitation, we monitored cerebral oxygenation and metabolism using hyperspectral near-infrared spectroscopy.
Multispectral photoacoustic tomography provides mapping of the tissue chromophore distributions using sets of tunable laser wavelengths. With the overall goal of studying the dynamics of cerebrospinal fluid in mice in vivo, our work aims to minimize the number of wavelengths to reduce scanning time, improve the temporal resolution, reduce the energy deposition and avoid the tracer photobleaching while maintaining high image quality. To select small sets of wavelengths we directly searched for the combinations of wavelengths providing the best and worst image quality in comparison with a reference image obtained using 131 closely spaced wavelengths between 680 and 940 nm in terms of the peak signal-to-noise ratio (PSNR).
View Article and Find Full Text PDFBackground: Maintaining cerebral oxygen delivery and metabolism during cardiac arrest (CA) through resuscitation is essential to improve the survival rate while avoiding brain injury. The effect of CA and cardiopulmonary resuscitation (CPR) on cerebral and muscle oxygen delivery and metabolism is not clearly quantified.
Methods and results: A novel hyperspectral near-infrared spectroscopy (hNIRS) technique was developed and evaluated to measure cerebral oxygen delivery and aerobic metabolism during ventricular fibrillation (VF) CA and CPR in 14 pigs.
Recent technological advancements in optical spectroscopy allow for the construction of hyperspectral (broadband) portable tissue oximeters. In a series of our recent papers we have shown that hyperspectral NIRS (hNIRS) has similar or better capabilities in the absolute tissue oximetry as frequency-domain NIRS, and that hNIRS is also very efficient in measuring temporal changes in tissue hemoglobin concentration and oxygenation. In this paper, we extend the application of hNIRS to the measurement of event-related hemodynamic and metabolic functional cerebral responses during simulated driving.
View Article and Find Full Text PDFNeonatal neuromonitoring is a major clinical focus of near-infrared spectroscopy (NIRS) and there is an increasing interest in measuring cerebral blood flow (CBF) and oxidative metabolism (CMRO2) in addition to the classic tissue oxygenation saturation (StO2). The purpose of this study was to assess the ability of broadband NIRS combined with diffusion correlation spectroscopy (DCS) to measured changes in StO2, CBF and CMRO2 in preterm infants undergoing pharmaceutical treatment of patent ductus arteriosus. CBF was measured by both DCS and contrast-enhanced NIRS for comparison.
View Article and Find Full Text PDFBroadband continuous-wave near-infrared spectroscopy (CW-NIRS) is an attractive alternative to time-resolved and frequency-domain techniques for quantifying cerebral blood flow (CBF) and oxygen metabolism in newborns. However, efficient light collection is critical to broadband CW-NIRS since only a small fraction of the injected light emerges from any given area of the scalp. Light collection is typically improved by optimizing the contact area between the detection system and the skin by means of light guides with large detection surface.
View Article and Find Full Text PDFWe present a broad-band, continuous-wave spectral approach to quantify the baseline optical properties of tissue and changes in the concentration of a chromophore, which can assist to quantify the regional blood flow from dynamic contrast-enhanced near-infrared spectroscopy data. Experiments were conducted on phantoms and piglets. The baseline optical properties of tissue were determined by a multi-parameter wavelength-dependent data fit of a photon diffusion equation solution for a homogeneous medium.
View Article and Find Full Text PDFThe goal of this study was to investigate the ability of independent component analysis in the time-spectral domain to isolate physiological sources of functional near infrared spectroscopy signals. We apply independent component analysis to the broadband fNIRS data acquired on the human forehead at 650 different wavelengths between 700 nm and 950 nm. To induce cerebral oxygenation changes we use the breath holding paradigm.
View Article and Find Full Text PDFThe aim is to study cerebral vascular functional connectivity during motor tasks and resting state using multichannel frequency-domain near-infrared spectrophotometry. Maps of 5.7 × 10.
View Article and Find Full Text PDFWe present the development of a continuous-wave method of quantifying the optical properties of a two-layered model of the human head using a broadband spectral approach. Absolute absorption and scattering properties of the upper and lower layers of phantoms with known optical properties were reconstructed from steady-state multi-distance measurements by performing differential fit analysis of the near-infrared reflectance spectrum between 700 and 1000 nm. From spectra acquired at 10, 20, and 30 mm, the concentration of a chromophore in the bottom layer was determined within an error of 10% in the presence of a 15 mm thick top layer.
View Article and Find Full Text PDFWe have compared cerebral hemodynamic changes measured by near-infrared spectroscopy (NIRS) with simultaneously acquired BOLD fMRI signals during breath hold challenge in humans. The oxy- and deoxyhemoglobin concentration changes were obtained from the same broadband NIRS data using four different quantitation methods. One method used only two wavelengths (690 nm and 830 nm), and three other methods used broadband data with different spectral fitting algorithms.
View Article and Find Full Text PDFConf Proc IEEE Eng Med Biol Soc
October 2012
Blood oxygenation level dependent (BOLD) functional MRI and near infrared optical tomography have been widely used to investigate hemodynamic responses to functional stimulation in the human brain. In this paper, we present a complete methodology for integrating the two imaging modalities to study the underlying physiological mechanism of the hemodynamic response in primary visual cortex. Using a specially designed MRI-compatible optical probe, optical imaging was conducted using a frequency-domain near infrared spectrometer.
View Article and Find Full Text PDFFunctional near infrared spectro-imaging (fNIRSI) is potentially a very useful technique for obtaining information about the underlying physiology of the blood oxygenation level dependent (BOLD) signal used in functional magnetic resonance imaging (fMRI). In this paper the temporal and spatial statistical characteristics of fNIRSI data are compared to those of simultaneously acquired fMRI data in the human visual cortex during a variable-frequency reversing checkerboard activation paradigm. Changes in the size of activated volume caused by changes in checkerboard reversal frequency allowed a comparison of the behavior of the spatial responses measured by the two imaging methods.
View Article and Find Full Text PDFAn integrated measurement system is described for performing simultaneous functional magnetic resonance imaging (fMRI) and diffuse optical tomography (DOT) for human brain mapping experiments. The components of this system consist of an MRI-compatible multi-overlapping-channel optical probe, methods for co-registration of optical and fMRI measurements, and DOT reconstruction algorithms with structural and physiological constraints derived from the MRI data. The optical probe is fully MRI-compatible in the sense that it produces negligible MR image distortion and does not require any modification to the MRI scanner or data acquisition protocol.
View Article and Find Full Text PDFProc SPIE Int Soc Opt Eng
July 2006
We use our new combined functional near infrared spectro-imaging (fNIRSI) and magnetic resonance imaging (MRJ) technique to compare fMRI and fNIRSI data at different activation conditions, to obtain new information about the underlying physiology of the blood oxygen level dependent (BOLD) signal used in fMRI, and to assess statistical characteristics of spatial functional information provided by the group analysis of fNIRSI data. To achieve these goals we have acquired simultaneously fNIRSI and fMRI data during the presentation of the checkerboard reversing with different frequencies, and analyzed these data following the standard correlation and group analysis of variance pathway used in functional neuroimaging. .
View Article and Find Full Text PDFA complete methodology has been developed to integrate simultaneous diffuse optical tomography (DOT) and functional magnetic resonance imaging (MRI) measurements. This includes development of an MRI-compatible optical probe and a method for accurate estimation of the positions of the source and detector optodes in the presence of subject-specific geometric deformations of the optical probe. Subject-specific head models are generated by segmentation of structural MR images.
View Article and Find Full Text PDFWe review our most recent results on near-IR studies of human brain activity, which have been evolving in two directions: detection of neuronal signals and measurements of functional hemodynamics. We discuss results obtained so far, describing in detail the techniques we developed for detecting neuronal activity, and presenting results of a study that, as we believe, confirms the feasibility of neuronal signal detection. We review our results on near-IR measurements of cerebral hemodynamics, which are performed simultaneously with functional magnetic resonance imaging (MRI) These results confirm the cerebral origin of hemodynamic signals measured by optical techniques on the surface of the head.
View Article and Find Full Text PDFWe present an integrated methodology for human brain mapping by simultaneous BOLD fMRI and NIR imaging. This methodology consists of three innovative components: the construction of MRI-compatible optical probes that can be affixed to any part of the human head inside a standard MRI head-coil with minimal MR image distortion, the accurate determination of optode positions on the head from MR images, and the application of a perturbation approach and Monte Carlo method to compute the integral kernel of the Born solution to the diffusion equation for baseline optical properties. This integrated approach has been used to demonstrate promising capabilities for studying functional hemodynamic activation in human visual cortex by simultaneous fMRI and NIR tomography.
View Article and Find Full Text PDFWe use near-infrared spectroscopy to investigate hemodynamic changes in humans during a breath holding exercise and their influence on the BOLD fMRI signal. We have quantitatively compared the BOLD fMRI signals with the hemoglobin concentration changes using correlation analysis of NIRS and fMRI data.
View Article and Find Full Text PDFNear-infrared spectro-imaging (NIRSI) is a quickly developing method for the in-vivo imaging of biological tissues. In particular, it is now extensively employed for imaging the human brain. In this non-invasive technique, the information about the brain is obtained from the analysis of spatial light bundles formed by the photons traveling from light sources to detectors placed on the surface of the head.
View Article and Find Full Text PDFThe integration of near-infrared (NIR) and functional MRI (fMRI) studies is potentially a powerful method to investigate the physiological mechanism of human cerebral activity. However, current NIR methodologies do not provide adequate accuracy of localization and are not fully integrated with MRI in the sense of mutual enhancement of the two imaging modalities. Results are presented to address these issues by developing an MRI-compatible optical probe and using diffuse optical tomography for optical image reconstruction.
View Article and Find Full Text PDFThe basic parameters for physiological measurements provided by near-infrared spectroscopy are the local absorption and scattering coefficients. For the adult human head, they have been difficult to measure noninvasively because of the layered structure of the head. The results of measurements of absorption and reduced scattering coefficients through the forehead on 30 adult volunteers using a multidistance frequency domain method are reported.
View Article and Find Full Text PDFBrain activity is associated with physiological changes, which alter the optical properties of the tissue in the near-infrared part of the spectrum. Two major types of optical signals following functional brain activation can be distinguished: a slow signal due to hemodynamic changes and a fast signal, which is directly related to neuronal activity. The fast signal is small and therefore difficult to detect.
View Article and Find Full Text PDF