We propose a novel x-ray fluorescence imaging setup for the in vivo detection of high-Z tracer distributions. The main novel aspect is the use of an analyzer-based, energy-resolved detection method together with a radial, scatter reducing collimator. The aim of this work is to show the feasibility of this method by measuring the Bragg reflected K-fluorescence signal of an iodine solution sample in a proof of principle experiment and to estimate the potential of the complete imaging setup using a Monte Carlo simulation, including a quantification of the minimal detectable tracer concentration for in vivo imaging.

View Article and Find Full Text PDF

XRF (X-ray fluorescence) is a powerful technique for elemental analysis with a high sensitivity. The resolution is presently limited by the size of the primary excitation X-ray beam. A test-bed for confocal-type XRF has been developed to estimate the ultimate lateral resolution which could be reached in chemical mapping using this technique.

View Article and Find Full Text PDF

Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit.

View Article and Find Full Text PDF

Introduction: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer.

View Article and Find Full Text PDF

Rationale And Background: The emission spectrum of an x-ray tube is determined by the anode and filter materials as well as by the high voltage being used. For mammography, typical anode materials are molybdenum (Mo), rhodium (Rh), and tungsten (W); molybdenum, rhodium, and aluminum are favored for filters. Mammography is a soft tissue imaging modality demanding a high spatial resolution as well as a high detector sensitivity.

View Article and Find Full Text PDF