Accreditation of an in vitro diagnostic assay according to the NF/EN/ISO 15189 standard requires to analyze its technical performance before implementation for routine use, and annually when reviewing effectiveness of quality controls. Performance is evaluated through repeatability, intermediate fidelity, accuracy and uncertainty of measurement. The coefficients of variation (CV) of the intra-assay and inter-assay precision tests must be compared with those of "peers" (results from laboratories employing the same method) and also with those obtained with "all methods", i.
View Article and Find Full Text PDFBackground: Peach is a common elicitor of food allergic reactions. Peach-induced immediate reactions may occur as benign pollen-food syndromes, usually due to birch pollen-related PR-10 cross-reactivity in temperate climates, and as potentially severe primary food allergies, predominantly related to nsLTP Pru p 3 in Mediterranean regions. The newly described peach allergen Pru p 7 has gained recent attention as a potential peach allergy severity marker.
View Article and Find Full Text PDFBackground: Currently, there are no histological criteria to diagnose irritable bowel syndrome (IBS). Our aims were (i) to examine the distribution of inflammatory cells in the colon of healthy and IBS subjects and (ii) to find histological diagnosis criteria for IBS.
Methods: Colonic biopsies were taken from four distinct regions of the colon from 20 controls (HC) and 11 patients with IBS (4 with constipation (IBS-C) and 7 with diarrhea (IBS-D) and embedded in paraffin.
Background: Allergen-specific serum immunoglobulin E detection and quantification have become an important step in allergy diagnosis and follow-up. In line with the current trend of laboratory test accreditation to international standards, we set out to design and assess an accreditation procedure for allergen-specific serum IgE.
Methods: Method validation according to the accreditation procedure under the EN ISO 15189 standard was carried out for allergen-specific immunoglobulin E determination using the fluoroimmunoenzymatic method ImmunoCAP(®) (ThermoFisher).
The molecule E2 is present on T lymphocytes and thymocytes and is implicated in rosette phenomenon most probably via interaction with CD2. The discrepancy observed between rosette levels and lymphocyte phenotypes in the follow-up of kidney-transplanted patients treated with antilymphocyte globulins (ALG), methylprednisolone and azathioprine leaded us to study the effect of ALG on E2 molecule.
View Article and Find Full Text PDF