Förster resonance energy transfer (FRET) and fluorescence lifetime imaging (FLIM) have been coupled with multiphoton microscopy to image in vivo dynamics. However, the increase in optical aberrations as a function of depth significantly reduces the fluorescent signal, spatial resolution, and fluorescence lifetime accuracy. We present the development of a time-resolved FRET-FLIM imaging system with adaptive optics.
View Article and Find Full Text PDFTime-correlated single-photon counting (TCSPC) is the gold standard for performing lifetime spectroscopy in biological assays. Traditional fluorescence lifetime imaging (FLIM) using laser scanning microscopes are inherently slow due to point scanning all pixels in the field-of-view. Wide-field implementations of TCSPC spectroscopy using microchannel plates benefit from particularly fast acquisition times at the expense of temporal resolution, and are fundamentally limited by photon counting rates.
View Article and Find Full Text PDFWe demonstrate an implementation of a centre-of-mass method (CMM) incorporating background subtraction for use in multifocal fluorescence lifetime imaging microscopy to accurately determine fluorescence lifetime in live cell imaging using the Megaframe camera. The inclusion of background subtraction solves one of the major issues associated with centre-of-mass approaches, namely the sensitivity of the algorithm to background signal. The algorithm, which is predominantly implemented in hardware, provides real-time lifetime output and allows the user to effectively condense large amounts of photon data.
View Article and Find Full Text PDFWe demonstrate diffraction limited multiphoton imaging in a massively parallel, fully addressable time-resolved multi-beam multiphoton microscope capable of producing fluorescence lifetime images with sub-50ps temporal resolution. This imaging platform offers a significant improvement in acquisition speed over single-beam laser scanning FLIM by a factor of 64 without compromising in either the temporal or spatial resolutions of the system. We demonstrate FLIM acquisition at 500 ms with live cells expressing green fluorescent protein.
View Article and Find Full Text PDFDeregulation of epidermal growth factor receptor (EGFR) signaling has been correlated with the development of a variety of human carcinomas. EGF-induced receptor dimerization and consequent trans- auto-phosphorylation are among the earliest events in signal transduction. Binding of EGF is thought to induce a conformational change that consequently unfolds an ectodomain loop required for dimerization indirectly.
View Article and Find Full Text PDFImaging the spatiotemporal interaction of proteins in vivo is essential to understanding the complexities of biological systems. The highest accuracy monitoring of protein-protein interactions is achieved using Förster resonance energy transfer (FRET) measured by fluorescence lifetime imaging, with measurements taking minutes to acquire a single frame, limiting their use in dynamic live cell systems. We present a diffraction limited, massively parallel, time-resolved multifocal multiphoton microscope capable of producing fluorescence lifetime images with 55 ps time-resolution, giving improvements in acquisition speed of a factor of 64.
View Article and Find Full Text PDFWe present a novel imaging system combining total internal reflection fluorescence (TIRF) microscopy with measurement of steady-state acceptor fluorescence anisotropy in order to perform live cell Förster Resonance Energy Transfer (FRET) imaging at the plasma membrane. We compare directly the imaging performance of fluorescence anisotropy resolved TIRF with epifluorescence illumination. The use of high numerical aperture objective for TIRF required correction for induced depolarization factors.
View Article and Find Full Text PDFThe epidermal growth factor receptor (EGFR) is a member of the ErbB family that can promote the migration and proliferation of breast cancer cells. Therapies that target EGFR can promote the dimerization of EGFR with other ErbB receptors, which is associated with the development of drug resistance. Understanding how interactions among ErbB receptors alter EGFR biology could provide avenues for improving cancer therapy.
View Article and Find Full Text PDFClassical FRET (Förster Resonance Energy Transfer) using two fluorescent labels (one for the donor and another one for the acceptor) is not efficient for studying the homodimerization of a protein as only half of the homodimers formed can be identified by this technique. We thus resorted to homoFRET detected by time-resolved Fluorescence Anisotropy IMaging (tr-FAIM). To specifically image the plasma membrane of living cells, an original combination of tr-FAIM and Total Internal Reflection Fluorescence Lifetime Imaging Microscope (TIRFLIM) was implemented.
View Article and Find Full Text PDFAmyloid peptide (Aβ) is generated by sequential cleavage of the amyloid precursor protein (APP) by β-secretase (Bace1) and γ-secretase. Aβ production increases after plasma membrane cholesterol loading through unknown mechanisms. To determine how APP-Bace1 proximity affects this phenomenon, we developed a fluorescence lifetime imaging microscopy-Förster resonance energy transfer (FLIM-FRET) technique for visualization of these molecules either by epifluorescence or at the plasma membrane only using total internal reflection fluorescence.
View Article and Find Full Text PDF